SAE J 968-2-1991 Diesel Injection Pump Testing - Part 2 Orifice Plate Flow Measurement.pdf
《SAE J 968-2-1991 Diesel Injection Pump Testing - Part 2 Orifice Plate Flow Measurement.pdf》由会员分享,可在线阅读,更多相关《SAE J 968-2-1991 Diesel Injection Pump Testing - Part 2 Orifice Plate Flow Measurement.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 _ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising ther
2、efrom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2015 SAE International All rights reserved. No part of this
3、publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-49
4、70 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/J968/2_201509 SURFACE VEHICLE RECOMMENDED PRACTICE J968-2 SEP2015 Issued 1966-08
5、 Revised 1991-05 Reaffirmed 2015-09 Superseding J968-2 DEC2002 Diesel Injection Pump TestingPart 2: Orifice Plate Flow Measurement RATIONALE J968-2 has been reaffirmed to comply with the SAE five-year review policy. 1. ScopeThis part of SAE J968 specifies the flow measuring system, including the fix
6、ture, to be used for flowtesting the single hole orifice plates used in an orifice plate type nozzle and holder assembly (described inSAE J968-1) which is intended for testing and setting diesel fuel injection pumps on test benches.The flow measuring system and fixture ensure accurate flow testing o
7、f the entire range of orifices from 0.4 to0.8 mm diameter as specified in SAE J968-1. It is intended primarily for use by the manufacturers of singlehole orifice plates.2. References2.1 Applicable PublicationsThe following publications form a part of this specification to the extent specifiedherein.
8、 The latest issue of SAE publications shall apply.2.1.1 SAE PUBLICATIONSAvailable from SAE, 400 Commonwealth Drive, Warrendale, PA 15096-0001.SAE J967Calibration Fluid for Diesel Injection Equipment SAE J968-1Diesel Injection Pump TestingPart1: Calibrating Nozzle and Holder Assemblies2.1.2 ISO PUBLI
9、CATIONAvailable from ANSI, 25 West 43rd Street, New York, NY 10036-8002.ISO 7440/2Road vehiclesFuel injection equipment testingPart 2: Orifice plate flow measurement3. Orifice Plate Flow Measuring System3.1 General DescriptionAn orifice plate flow measuring system shall comprise:a. Orifice Plate Hol
10、ding Fixture (shown in Figure 1)b. Fluid Supply Circuit and Flow Measuring Device (an example is shown in Figure 2)c. Flow Overcheck DeviceOPTIONAL. (This device is for periodic overchecking of the accuracy of theprimary flow measurement device in (b) and is specified in Appendix A.1.)FIGURE 1ORIFIC
11、E PLATE HOLDING FIXTURE FOR FLOW MEASUREMENTFIGURE 2FLUID SUPPLY CIRCUIT WITH PRESSURE AND TEMPERATURE CONTROLAND FLOW-MEASURING DEVICE_ SAE INTERNATIONAL J968-2 SEP2015 2 of 6The system shall be designed and constructed to minimize fluid evaporation, contamination, aeration, andinstability of press
12、ure and temperature.Flow values obtained by alternative systems shall require correlation with values determined using theprevious system.3.2 Orifice Plate Holding FixtureThe functionally critical details and dimensions of the fixture are shown inFigure 1. Dimensions not specified and construction t
13、echniques are left to the discretion of the manufacturer ofthe fixture, but shall be such that the fixture has unrestricted and undistributed flow.4. Flow Measuring Procedure4.1 General Requirementsa. The orifice plates shall be clamped in a fixture conforming to Figure 1.b. The following monitoring
14、 points shall be provided and the values measured or verified:1. Orifice inlet temperature2. Orifice inlet pressure3. Orifice outlet pressurec. The fluid shall enter the orifice through the entry cone.d. The flow through each orifice plate shall be measured individually.e. The fluid in the flow circ
15、uit shall conform to SAE J967. Viscosity and specific gravity shall bemeasured frequently and the fluid shall be discarded if it ceases to conform to SAE J967.4.2 Reference ConditionsThe orifice plate flow values stated in Part 1 of this document refer to volumetric flowrate measured (or adjusted to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ96821991DIESELINJECTIONPUMPTESTINGPART2ORIFICEPLATEFLOWMEASUREMENTPDF

链接地址:http://www.mydoc123.com/p-1027344.html