SAE J 1939-13-2016 Off-Board Diagnostic Connector.pdf
《SAE J 1939-13-2016 Off-Board Diagnostic Connector.pdf》由会员分享,可在线阅读,更多相关《SAE J 1939-13-2016 Off-Board Diagnostic Connector.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions.Copyright 2016 SAE InternationalAll rights reserved. No part of this publi
3、cation may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE.TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada)Tel: +1 724-776-4970 (out
4、side USA)Fax: 724-776-0790Email: CustomerServicesae.orgSAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedback on this Technical Report, please visitHTTP:/STANDARDS.SAE.ORG/J1939/13_201610SURFACE VEHICLERECOMMENDED PRACTICEJ1939-13 OCT2016Issued 1999-07Revised 2016-10Superseding
5、 J1939-13 OCT2011Off-Board Diagnostic ConnectorRATIONALEThis revision adds reference to SAE J1939-16 baud rate detection when a diagnostic tool is designed to support either 250kbps or 500 kbps vehicle networks. KbKbFOREWORDThe SAE J1939 communications network is defined using a collection of indivi
6、dual SAE J1939 documents based upon the layers of the Open System Interconnect (OSI) model for computer communications architecture. The SAE J1939-13 document defines the diagnostic connectors for off-board connection to the SAE J1939 communications network.The SAE J1939 communications network is a
7、high speed ISO 11898-1 CAN based communications network that supportsreal-time closed loop control functions, simple information exchanges, and diagnostic data exchanges between Electronic Control Units (ECUs) physically distributed throughout the vehicle. The SAE J1939 communications network is dev
8、eloped for use in heavy-duty environments and suitable for horizontallyintegrated vehicle industries. The SAE J1939 communications network is applicable for light-duty, medium-duty, and heavy-duty vehicles used on-road or off-road, and for appropriate stationary applications which use vehicle derive
9、d components (e.g., generator sets). Vehicles of interest include, but are not limited to, on-highway and off-highway trucks and their trailers,construction equipment, and agricultural equipment and implements. The physical layer aspects of SAE J1939 reflect its design goal for use in heavy-duty env
10、ironments. Horizontally integrated vehicles involve the integration of different combinations of loose package components, such as engines and transmissions, that are sourced from many different component suppliers. The SAE J1939 common communication architecture strives to offer an open interconnec
11、t system that allows the ECUs associated with different component manufacturers to communicate with each other.SAE INTERNATIONAL J1939-13 OCT2016 Page 2 of 17TABLE OF CONTENTS1. SCOPE. 22. REFERENCES. 32.1 Applicable Documents . 32.1.1 SAE Publications 32.1.2 ISO Publications. 33. OFF-BOARD DIAGNOST
12、IC CONNECTOR 33.1 General Requirements. 33.1.1 Mounting 33.1.2 Serviceability 53.2 Connector Performance Requirements . 53.2.1 Connect/Disconnect. 53.2.2 Environmental Requirements. 63.3 Physical Requirements 63.4 Connector Color . 63.5 Circuit Assignments and Pin Usage Requirements . 63.5.1 Type 1
13、Connector Circuit Assignments 63.5.2 Type 2 Connector Circuit Assignments 73.5.3 Pin Usage Requirements . 73.6 Connector Mechanical Requirements 94. NOTES. 174.1 Revision Indicator. 17Figure 1 Mated envelope 4Figure 2 Recommended cylindrical access envelope 5Figure 3 Flange mount diagnostic receptac
14、le connector Type 1 (black or grey) . 10Figure 4 Flange mount diagnostic receptacle connector Type 2 (green) 10Figure 5 In-line diagnostic receptacle connector Type 1 (black or grey) . 11Figure 6 In-line diagnostic receptacle connector Type 2 (green). 11Figure 7 Diagnostic plug connector Type 1 (bla
15、ck or grey) . 12Figure 8 Diagnostic plug connector Type 2 (green). 12Figure 9 Friction-locking plug connector Type 1 (black or grey) 13Figure 10 Friction-locking plug connector Type 2 (green) . 13Figure 11 Interface details Type 1 (black or grey) 14Figure 12 Interface details Type 2 (green) . 15Figu
16、re 13 Mating combinations and keying 16Table 1 Circuit assignments for Type 1 connector 6Table 2 Circuit assignments for Type 2 connector 7Table 3 Type 1 and Type 2 vehicle connector - pin usage description 8Table 4 Type 1 and Type 2 tool connector - pin usage description 91. SCOPESAE J1939-13 speci
17、fies the diagnostic connectors used for off-board connection to a vehicles SAE J1939 communication links. The defined diagnostic connectors support connection to the twisted shielded pair media (SAE J1939-11), the unshielded twisted pair (SAE J1939-15), the twisted pair of (SAE J1939-14), as well as
18、 the twisted unshielded quad media (ISO 11783-2). SAE INTERNATIONAL J1939-13 OCT2016 Page 3 of 172. REFERENCESGeneral information regarding this series of documents is found in SAE J1939.2.1 Applicable DocumentsThe following publications form a part of this specification to the extent specified here
19、in. Unless otherwise indicated, the latest issue of SAE publications shall apply.2.1.1 SAE PublicationsAvailable from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or +1 724-776-4970 (outside USA), www.sae.org.SAE J1708 Serial Data Co
20、mmunications Between Microcomputer Systems in Heavy-Duty Vehicle ApplicationsSAE J1939-11 Physical Layer, 250 kbps, Twisted Shielded PairSAE J1939-14 Physical Layer, 500 kbps SAE J1939-15 Physical Layer, 250 kbps, Un-Shielded Twisted Pair (UTP)SAE J1939-16 Automatic Baud Rate Detection ProcessSAE J2
21、030 Heavy-Duty Electrical Connector Performance StandardSAE J2202 Heavy-Duty Wiring Systems for On-Highway Trucks2.1.2 ISO PublicationsCopies of these documents are available online at http:/webstore.ansi.org/ISO 11783-2 Tractors and machinery for agriculture and forestrySerial control and communica
22、tions data networkPhysical layerISO 11898 Road vehiclesInterchange of digital informationController area network (CAN) for high speed communication3. OFF-BOARD DIAGNOSTIC CONNECTORThis section describes the Off-Board Diagnostic connector used on the vehicle to get access to the vehicle communication
23、 links.3.1 General Requirements3.1.1 MountingThe connector shall be mounted inside the cab in a location that is easily accessible according to the guidelines as follows.However, applications subject to OBD requirements must comply with the applicable regulatory requirements.a. For on road heavy tru
24、cks, the connector should be mounted on the driver side and if possible, accessible from the ground next to the cab.b. For busses, the connector should be located within reach of the operators seat. For rear engine busses, an additional connector may be mounted in the engine compartment that will al
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ1939132016OFFBOARDDIAGNOSTICCONNECTORPDF

链接地址:http://www.mydoc123.com/p-1026629.html