SAE J 1533-1993 Operator Enclosure Air Filter Element Test Procedure Recommended Practice《操作员附件空气滤芯测试程序的推荐性实施规程 1993年6月》.pdf
《SAE J 1533-1993 Operator Enclosure Air Filter Element Test Procedure Recommended Practice《操作员附件空气滤芯测试程序的推荐性实施规程 1993年6月》.pdf》由会员分享,可在线阅读,更多相关《SAE J 1533-1993 Operator Enclosure Air Filter Element Test Procedure Recommended Practice《操作员附件空气滤芯测试程序的推荐性实施规程 1993年6月》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirelyvoluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefro
2、m, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.QUESTIONS REGARDING THIS DOCUMENT: (724) 772-8512 FAX: (724) 776-0243TO PLACE A DOCUMENT
3、 ORDER; (724) 776-4970 FAX: (724) 776-0790SAE WEB ADDRESS http:/www.sae.orgCopyright 1993 Society of Automotive Engineers, Inc.All rights reserved. Printed in U.S.A.SURFACEVEHICLE400 Commonwealth Drive, Warrendale, PA 15096-0001RECOMMENDEDPRACTICEAn American National StandardJ1533ISSUEDJUN93Issued 1
4、993-06OPERATOR ENCLOSURE AIR FILTER ELEMENT TEST PROCEDUREThis document is technically equivalent to ISO DIS 10263.ForewordThis Document has not changed other than to put it into the new SAE Technical Standards BoardFormat.It is difficult, if not impossible, to select a generic calculation that woul
5、d enable one to determine the exact size offilter for all applications. Determining factors that must be taken into consideration are:a. The amount of fresh air required to maintain operator enclosure pressurization.b. The quantity of conditioned air that will be recirculated and provisions to contr
6、ol the amount ofrecirculation.c. The air handling units (blowers) ability to produce an adequate amount of flow to overcome theresistance of the ductwork and filtration system.1. ScopeThis SAE Recommended Practice establishes a uniform test procedure for determining performancelevels of operator enc
7、losure panel type air filters on off-road, self-propelled work machines used inconstruction, general-purpose industrial, agriculture, and forestry as defined in SAE J1116 and equipped withan operator enclosure with a powered fresh air system.2. References2.1 Applicable PublicationsThe following publ
8、ications form a part of this specification to the extent specifiedherein. The latest issue of SAE publications shall apply.2.1.1 SAE PUBLICATIONSAvailable from SAE, 400 Commonwealth Drive, Warrendale, PA 15096-0001.SAE J726 JUN93Air Cleaner Test CodeSAE J1116 JUN86Categories of Off-Road Self-Propell
9、ed Work MachinesSAE J1533 Issued JUN93-2-3. Definitions3.1 Operator Enclosure Air Filter ElementA medium in which particulate is removed from the incoming airsupply.3.2 EfficiencyThe ability of the air filter element to remove particulate. This will be expressed by Equation 1:(Eq. 1)4. Air Filter El
10、ement Performance TestThe test shroud configurations for the operator enclosure filtercomparison tests are outlined in 4.1.1 and Figure 1. This test procedure also designates a recommendedintake velocity for the dust mixing chamber Figure 1.4.1 Test Equipment and Instrumentation4.1.1 Air flow restri
11、ction and pressure drop test is to be conducted using a minimum of three points, 80%, 100%,and 120% of rated air flow (use element restriction test setup shown in Figure 2). Condition the unit to betested at least 30 min under temperature and humidity conditions equivalent to those in the test area.
12、To determine the resistance to air flow, particulate holding capacity, particulate removal efficiency, andsealing characteristics, use the equipment described in Figure 2. For element configurations other thanpanel type, reference SAE J726.4.1.2 Use a dust metering device (Figure 3) which when used
13、with the dust injector (Figure 4) is capable ofmetering dust over the range of delivery rates required. This dust feed system shall not change the primaryparticle size distribution of the particulate. The average delivery rate shall be within 5% of the desired rateand the deviation in the instantane
14、ous delivery rate from the average shall be no more than 5%.4.2 Test Conditions and Material4.2.1 STANDARD CONDITIONAll air flow measurements are to be corrected to a standard condition of 25 C at100kPa.4.2.2 TEST DUST1Shall be standardized and shall be of two grades labeled fine and coarse. For typ
15、ical particlesize distributions and chemical composition, refer to Table 1, Table 2, and Table 3:1. Obtainable from Powder Technology, Inc., Burnsville, Minnesota.TABLE 1CHEMICAL ANALYSIS OF TEST DUSTChemical % of WeightSiO2 6769Fe2O3 35Al2O3 1517CaO 24MgO 0.51.5Total Alkalis 35Ignition Loss 23Effic
16、iency%Increase in weight offilter element under testIncrease in weightof filter elementunder testIncrease in weightof the absolutefilter+-100=,SAE J1533 Issued JUN93-3-FIGURE 1TEST SHROUDSAE J1533 Issued JUN93-4-FIGURE 2EFFICIENCY/CAPACITY AIR FILTER ELEMENT TEST SETUPSAE J1533 Issued JUN93-5-FIGURE
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ15331993OPERATORENCLOSUREAIRFILTERELEMENTTESTPROCEDURERECOMMENDEDPRACTICE 操作员 附件 空气 测试 程序 推荐 实施 规程

链接地址:http://www.mydoc123.com/p-1026380.html