1、AEROSPACESTANDARDIssued 1985-12SAE AS 8042MANIFOLD PRESSURE INSTRUMENTS1.PURPOSE:This Aerospace Standard establishes the minimum safe performance standards for manifold pressure instruments, primarily for use with aircraft reciprocating engines.2.SCOPE:This Standard covers two basic types of manifol
2、d pressure instruments:Type I - Direct IndicatingType II - Remote Indicating; comprised of separate transmitter and indicator3.GENERAL STANDARDS:3.1Material:Materials shall be of a quality which experience and/or tests have demonstrated to be suitable and dependable for use in aircraft instruments.3
3、.2Workmanship:Workmanship shall be consistent with high grade instrument manufacturing practice.3.3Interchangeability:Instruments and instrument systems which are identified with the same manufacturers part or model number shall be completely interchangeable.3.4Compatibility:If components of Type II
4、 instruments are individually acceptable but require matching for proper operation, they shall be identified in a manner that will insure performance to the requirements of this Standard.3.5Accessibility of Controls:Controls, if provided, which are not normally adjustable in flight shall not be read
5、ily accessible to flight personnel when the instrument is installed in accordance with the manufacturers instructions.SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely volu
6、ntary, and its applicability and suitability for any particular use, including any patent infringement arising therefrom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your w
7、ritten comments and suggestions. Copyright 2008 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written per
8、mission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org Reaffirmed 2008-02AS 8042 Page 2 3.6Self-Test Provisions:Self-test provisions, if included, shall be
9、 spring-loaded or otherwise arranged to automatically return to the normal operating mode following self-testing.3.6.1In-Flight Testing:In-flight, self-test activation controls, if included, must provide a means to warn the pilot or appropriate flight crew member of this mode of operation.3.6.2Combi
10、ned Systems:If the equipment contains integral arrangements to permit pre-flight and/or in-flight self-test checks on the operation of the equipment in combination with other aircraft subsystems, a means shall be provided to deactivate any subsystem which might be adversely affected during the self-
11、test cycle.3.6.3Effect of Tests:The application of the specified tests shall not produce a condition which would be detrimental to the continued performance of the aircraft or the instrument.3.7Malfunction Indication:Means shall be provided to indicate malfunctions or failures of Type II instruments
12、 in a positive manner.3.7.1Power Failure Indication:Means shall be incorporated in the instrument to indicate when adequate electrical power (voltage and/or current of all required phases) is not being made available for proper operation of the instruments. Dial lights are considered to be self-indi
13、cating.3.7.2Remote Indicator:Means shall be incorporated to detect an internal malfunction or loss of information-valid signal from the remote source providing the information to be indicated.3.8Fail-Safe Provisions:No failure or malfunction of the instrument system shall introduce unsafe signal or
14、power effects to associated equipment.3.9Multiple Mode:When an instrument has more than one mode of operation, each mode shall be identified and means shall be provided to indicate the mode.3.10Display:3.10.1Indicating Means:The functions shall be indicated by means of one or more pointers, dials, t
15、apes, drums, digital displays or other devices. Unless otherwise specified, relative motion of the index with respect to the scale when moving elements are employed (either the index or the scale may be the moving element) shall be clockwise, up or to the right for increasing values. In a dual indic
16、ator, the pointers or other indicating means shall be clearly identified as 1 and 2 or as 3 and 4.3.10.2Graduations:The graduations shall be arranged to provide the maximum degree of readability consistent with the accuracy of the instrument.AS 8042Page 3 3.10.3Numerals:The display shall include suf
17、ficient numerals to permit quick and positive identification of each significant graduation.3.10.4Ambiguity:Appropriate means shall be provided to prevent ambiguous indications within the extremes of the operating range of the instrument.3.10.5Instrument Title:The instrument title, MANIFOLD PRESSURE
18、 or MANIF PRESS, shall be of the same approximate size but no larger than the numerals. The title may be of the same finish as the numerals.3.10.6Instrument Function:Where more than one function is displayed on a single instrument, the function name, when used, shall be of the same approximate size
19、but no larger than the numerals and/or instrument title.3.10.7Units of Measure:The units of measure (in Hg abs or cm Hg abs) shall appear on the display in lettering noticeably smaller than either the numerals or the title.3.10.8Dial Finish:Where applicable, unless otherwise specified by the user, m
20、atte white material shall be applied to graduations, numerals and pointers. Non-functional surfaces shall be dull black. The manufacturers trademark shall not appear on the dial unless in black-on-black. 3.10.9Visibility:Pointer(s) and dial markings shall be visible from any point within the frustru
21、m of a cone, the side of which makes an angle of 30 with the perpendicular to the dial and the small diameter of which is the aperture of the instrument case. The distance between the dial and the cover glass shall be a practical minimum and shall not exceed .12 in (3.0 mm) for a single indicator an
22、d .19 in (4.8 mm) for a dual indicator.3.11Cover Glass:The cover glass of the instrument shall de clear, flat, colorless and free from flaws which would adversely affect the readability of the instrument. The total reflectance of the glass, including the integral lighting wedge, if applicable, shall
23、 not exceed 10% of the incident light. This reflectance applies over the visible light spectrum from 450 to 600 millimicrons and over an incident solid angle of 60 perpendicular to the viewing plane.3.12Integral Lighting:When integral lighting is provided, it must under normal cockpit lighting condi
24、tions make all markings within the required visibility angle easily readable. No direct light shall radiate from the instrument within an angle of 45 either side of the vertical center line of the instrument face in the horizontal plane, not above 30 to the longitudinal axis in the vertical plane.AS
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS80421985MANIFOLDPRESSUREINSTRUMENTS 歧管 压力 PDF

链接地址:http://www.mydoc123.com/p-1025384.html