1、 AEROSPACESTANDARDSubmitted for recognition as an American National StandardMINIMUM PERFORMANCE STANDARDTEMPERATURE INSTRUMENTSSAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. Theuse of this report is entir
2、ely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefrom, is thesole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites
3、your writtencomments and suggestions.Copyright 1996 Society of Automotive Engineers, Inc.All rights reserved. Printed in U.S.A.Land Sea Air and SpaceFor Advancing MobilityThe Engineering SocietyINTERNATIONAL400 Commonwealth Drive, Warrendale, PA 15096-0001Issued 1977-01Revised 1996-09REV.AS8005 AFOR
4、EWORDChanges in the revision are format/editorial only.1. SCOPE:This SAE Aerospace Standard (AS) applies to all temperature instruments used in aircraftapplications and environments. The word “instrument” as used in this Standard encompasses onlythe display device and does not include the temperatur
5、e sensors. Examples of the types ofinstruments covered are as follows:1.1 Temperature instruments using a Resistance Temperature Detector for temperature sensing.1.2 Temperature instruments using a thermocouple for temperature sensing.1.3 Temperature instruments using an averaging thermocouple harne
6、ss for temperature sensing.1.4 Temperature instruments receiving an input from a signal conditioning unit.1.5 Temperature instruments receiving an input from another temperature instrument.1.6 Temperature instruments receiving an input from other temperature sensing devices.1.7 Purpose:This document
7、 establishes the essential minimum performance requirements for electrical typetemperature instruments primarily for use on aircraft which may subject the instruments toenvironmental conditions specified herein.SAE AS8005 Revision A- 2 -2. APPLICABLE DOCUMENTS:The following publications form a part
8、of this document to the extent specified herein. The latestissue of SAE publications shall apply. The applicable issue of other publications shall be the issuein effect on the date of the purchase order. In the event of conflict between the text of thisdocument and references cited herein, the text
9、of this document takes precedence. Nothing in thisdocument, however, supersedes applicable laws and regulations unless a specific exemption hasbeen obtained.2.1 RTCA Publications:Available from RTCA Inc., 1140 Connecticut Avenue, NW, Suite 1020, Washington, DC 20036.RTCA Document No. DO-138, June 27
10、, 19682.2 FAA Publications:Available from Federal Aviation Administration, 800 Independence Avenue, SW, Washington, DC20591.Federal Aviation Regulations, Vol. III, Part 25Airworthiness Standards: Transport Category Airplanes3. GENERAL STANDARDS:3.1 Classification by Instrument Accuracies:Class I Cla
11、ss Ia: 0.1% of indicated rangeClass Ib: 0.2% of indicated rangeClass Ic: 0.5% of indicated rangeClass II Class IIa: 1% of indicated rangeClass III Class IIIa: 2% of indicated rangeClass IIIb: 3% of indicated rangeClass IIIc: 5% of indicated range3.2 Method of Indication:3.2.1 If applicable, relative
12、 motion of the index with respect to the scale (either the index or the scalemay be the moving element) shall be clockwise, up, or to the right for increasing temperature.3.2.2 Sufficient numerals and graduations shall be provided to positively and quickly identifytemperature indications. The inscri
13、ption “C”, “F”, or “K”, as appropriate, shall also appear onthe instrument face.SAE AS8005 Revision A- 3 -3.2.3 Indications beyond the normal range of the instrument shall not be displayed in a mannerinterpretable as an on-scale reading or as an off-scale reading in the wrong direction.3.3 Power Mal
14、function:Means (e.g. warning flags, off-scale indication) shall be incorporated in the instrument to indicatethe loss of essential power for proper operation of the indicator. This does not apply to the lossof signal used to drive the instrument where no other power is used.3.4 Markings:Where termin
15、al posts are used for thermocouple connections, they shall be of different sizes andshall be distinctly identified to indicate plus for the larger terminal, and minus for the smallerterminal. The thermocouple material, and when applicable, the required external resistance ofthe lead and thermocouple
16、, or the thermocouple circuit shall be plainly marked.3.5 Signal (Sensor) Characteristics:Instruments shall be calibrated to indicate temperature in accordance with the signalcharacteristic specified by the manufacturer of the instrument in his installation instructions.3.6 Adjustments:When provided
17、, external adjustment provisions shall have sufficient friction so that they will notchange in the environment encountered in service.3.7 Accessibility of Controls:Controls which are not normally adjusted in flight shall not be readily accessible to flightpersonnel when the equipment is installed in
18、 accordance with the manufacturers instructions.3.8 Effects of Tests:Unless otherwise stated, the application of the specified tests shall produce no subsequentlydiscernible condition which would be detrimental to the continued performance of the equipment.3.9 Interchangeability:Instruments and comp
19、onents which are identified in accordance with the requirements applicableto this standard and are identified with a manufacturers part and/or model number shall bedirectly and completely interchangeable with all items identified with that part and/or modelnumber.SAE AS8005 Revision A- 4 -3.10 Fire
20、Resistance:Except for small parts (such as knobs, fasteners, seals, grommets, and small electrical parts)that would not contribute significantly to the propagation of a fire, all materials used must beself-extinguishing when tested in accordance with the requirements of Federal AviationRegulation 25
21、.1359 (d) and Appendix F thereto, with the exception that materials tested may beconfigured in accordance with paragraph (b) of Appendix F or may be configured as used.3.11 Instrument Cover Glass Reflectance:The total reflectance of the instrument cover glass including the integral lighting wedge, i
22、fapplicable, shall not exceed 10% of the incident light. This reflectance applies over the visiblelight spectrum from 450 milli-microns to 600 milli-microns, and over an incident solid angle of60 perpendicular to the viewing plane.4. MINIMUM PERFORMANCE STANDARDS UNDER STANDARD CONDITIONS:4.1 Standa
23、rd Atmospheric Conditions:Unless otherwise specified herein, all tests required shall be made at atmospheric conditionsspecified in paragraph 3.4 of DO-138.4.2 Attitude:Unless otherwise specified herein, all tests shall be conducted with the instrument in its normaloperating attitude.4.3 Vibration t
24、o Minimize Friction:Unless otherwise specified herein, all tests for performance may be conducted in accordance withinstructions found in paragraph 3.5 of DO-138.4.4 Power Input Voltage:4.4.1 Direct Current: Unless otherwise specified, when the equipment is designed for operation froma current power
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS8005A1996MINIMUMPERFORMANCESTANDARDTEMPERATUREINSTRUMENTS 温度 仪器 最低 性能 标准 PDF

链接地址:http://www.mydoc123.com/p-1025356.html