SAE AS 8004-1975 Minimum Performance Standard for Turn and Slip Instrument《转弯倾斜指示仪的最低性能标准》.pdf
《SAE AS 8004-1975 Minimum Performance Standard for Turn and Slip Instrument《转弯倾斜指示仪的最低性能标准》.pdf》由会员分享,可在线阅读,更多相关《SAE AS 8004-1975 Minimum Performance Standard for Turn and Slip Instrument《转弯倾斜指示仪的最低性能标准》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefr
2、om, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2008 SAE International All rights reserved. No part of this publication may
3、 be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA) F
4、ax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org AS 8004 - 2 -3.7 Visibility: Turn and slip indications must be visible from any point within the frustum of a cone the side of which makes an angle of at least 30 degrees with the perpendicular to the dial and the smal
5、l diameter of which is the aperture of the instrument case.3.8 Power Malfunction Indication: For Types II and III instruments, means must be incorporated in the instrument to indicate the loss of adequate power to the rate-of-turn gyro and primary signal voltages to the pointer in remote instruments
6、. The indicating means must indicate a failure or malfunction in a positive manner.3.9 Reflectance, Cover Glass: The total reflectance of the instrument cover glass including the integral lighting wedge, if applicable, shall not exceed 10% of the incident light. This reflectance applies over the vis
7、ible light spectrum from 450 milli-microns to 600 milli-microns, and over an incident solid angle of 60 perpendicular to the viewing plane.4. PERFORMANCE STANDARDS UNDER STANDARD CONDITIONSThe test conditions applicable to a determination of the performance of turn and slip instruments are set forth
8、 in Appendix A of this standard. All instruments shall be tested in accordance with the manufacturers recommendations. The manufacturer shall conduct sufficient tests to prove compliance with these Minimum Performance Standards.4.1 Turn Indicator Starting: Instrument performance must be achieved wit
9、hin three (3) minutes after normal rated power is applied for both air and electric operated instruments. By application of 50% of rated suction of air operated indicators and 80% of rated voltage for electrically operated indicators, the gyro must start, continue to rotate, and provide an adequate
10、indication of turning motions. However, under the reduced power conditions, the turn indicator sensitivity and damping requirements do not apply. If the instrument incorporates a gyro speed monitoring device which provides a positive indication when the gyro speed is below that necessary to meet ins
11、trument performance, the starting time may exceed three minutes.4.2 Turn Indicator Characteristics:(a) Sensitivity When the instrument is operating under rated power and subjected to the turning rates specified about the vertical axis, the turn instrument deflection, in inches or millimetres, must b
12、e within the limits of either Column A or B. The indicator movement must be smooth.Column A values pertain to instruments set to indicate a standard rate of turn (180 per minute)with one indicator unit deflection. Column B provides double this displacement for indicators providing increased sensitiv
13、ity.For instruments possessing display features such that the dimensional characteristics prescribed by Columns A and B do not apply, the applicant may demonstrate that the indicator can reliably indicate the prescribed rates of turn with clarity and accuracy equivalent to that specified in Column A
14、 or B.Rate of Turn (Degrees per Minute)Deflection of IndicatorColumn A Column BInches mm Inches mm036901803600 0.0151/32 1/645/64 1/325/32 1/325/16 1/160 0.40.8 0.42.0 0.84.0 0.87.9 1.60 0.0151/16 1/645/32 1/325/16 1/169/16 1/80 0.41.6 0.44.0 0.87.9 1.614.3 3.2AS 8004- 3 -(b) Damping The time for th
15、e turn indicator or index to return to the zero mark without crossing the zero mark must be at least two but not more than four seconds, when the instrument is suddenly stopped after being rotated about its vertical axis at a rate that causes full-scale pointer or index deflection.4.3 Slip Indicator
16、 Characteristics: The slip indicator must operate freely when the instrument is rotated about its longitudinal axis with the dial vertical. The range of slip indicators must be at least 7 degrees either side of vertical. With the instrument in its normal position for mounting, the position of the in
17、dicator must be zero (0) 1/32 inch (0 0.8 mm).(a) Damping. The time for the slip indicator to move from the zero position of the slip indication to the test position must not be less than 0.2 seconds following a sudden rotation of the instrument from a position of 12 degrees bank through the vertica
18、l to 12 degrees of opposite bank.(b) Slip Indicator Filling. Instruments using a liquid as a damping medium for the slip indicator must be so designed and filled that no part of an air bubble will be visible from a point 12 inches (30.5 cm) directly in front of the instrument when the instrument is
19、rotated to an angle of roll of 45 degrees.5. PERFORMANCE STANDARDS UNDER ENVIRONMENTAL CONDITIONSUnless otherwise specified herein, the measurement procedures applicable to a determination of the performance of turn and slip instruments under environmental conditions are set forth in Radio Technical
20、 Commission for Aeronautics (RTCA) Document No. DO-138, entitled “Environmental Conditions and Test Procedures for Airborne Electronic/Electrical Equipment and Instruments” dated 27 June 1968. Performance tests which must be made after subjection to test environments may be made after exposure to se
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS80041975MINIMUMPERFORMANCESTANDARDFORTURNANDSLIPINSTRUMENT 转弯 倾斜 指示 最低 性能 标准 PDF

链接地址:http://www.mydoc123.com/p-1025355.html