SAE AS 8003-1974 Minimum Performance Standard for Automatic Pressure Altitude Reporting Code Generating Equipment《自动压力高度数据传送码生成设备的最低性能标准》.pdf
《SAE AS 8003-1974 Minimum Performance Standard for Automatic Pressure Altitude Reporting Code Generating Equipment《自动压力高度数据传送码生成设备的最低性能标准》.pdf》由会员分享,可在线阅读,更多相关《SAE AS 8003-1974 Minimum Performance Standard for Automatic Pressure Altitude Reporting Code Generating Equipment《自动压力高度数据传送码生成设备的最低性能标准》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefr
2、om, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2008 SAE International All rights reserved. No part of this publication may
3、 be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA) F
4、ax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org AS 8003-2 -3.6 Pressure Datum: The code generator outputs shall be referenced to 29.9213 in. Hg absolute or 1013.25 millibars or 760.001 mm Hg absolute, for zero feet indication and shall supply the encoded output valu
5、es in accordance with the U.S. Standard Pressure Altitude Tables 1962. If the code generation equipment forms part of an altimeter system, the altimeters barometric setting system shall not affect the encoded outputs.3.7 Operating Range: The operation range for all pressure altitude code generating
6、devices shall start at or below -1000 feet (-304.8 metres) M.S.L. pressure altitude and shall continue to the upper pressure altitude limit as indicated on the equipment nameplate.3.8 Power Loss: If electrical power is used to operate the pressure altitude code generating equipment, means shall be i
7、ncorporated in the equipment to indicate the loss of electrical power or the effect thereof, unless the electrical power to operate the code generating equipment is supplied by an ATC Transponder which also supplies an indication of this power loss. Under the power loss condition, the equipment shal
8、l: a) Provide for the deactivation of the generated digital code outpit in a manner which removes the altitude information supplied to the ATC Transponder.b) Provide means to indicate the loss of electrical power in a positive manner.Power from the ATC Transponder as related to the generated encoded
9、 output does not require power lossindications.3.9 Encoded Altitude Return Lead, Common: The opening of the common lead or the equivalent thereto shallresult in no encoded altitude information being transmitted to the ATC Transponder. If the code generator requires its own power supply to generate t
10、he code, the circuit design shall be such that this function of opening the common lead or the equivalent thereto is not impaired.3.10 Overrange Operation: Appropriate means shall be incorporated within the code generating equipment to provide for encoded output for at least the extremes of the spec
11、ified operating range of the instrument.Overrange of the instrument shall not cause the generation of any encoded output which is within the specified operating range of the instrument.3.11 Correspondence: The pressure altitude generated encoded output shall correspond to the displayed pressure alti
12、tude indication used to maintain flight altitude to within 125 feet (38.1 metres) when the pressure datum is set for 29.921 inches of mercury absolute (1013.25 millibars or 760 mm Hg Abs.).3.11.1 For any barometric setting within the operating range of barometric settings for the pressure altitudedi
13、splay, the generated encoded output which is transmitted to the ATC Transponder shall correspond to the displayed altitude value to within 125 feet (38.1 metres) when the displayed altitude value is corrected for the difference in feet as a result of the applied barometric setting and the value of t
14、he displayed pressure altitude based on the pressure datum of 29.921 inches of mercury absolute (1013.25 millibars or 760 mm Hg Abs.).3.11.2 The requirements specified in 3.11 and 3.11.1 shall be applicable to both increasing and decreasingpressure altitude changes.NOTE: For example, if the encoded
15、output is 10,000 feet (3048 metres), the pressure altitude display (when corrected for the actual barometric setting in feet and the pressure datum) shall indicate 10,000 feet (3048 metres) 125 feet (38.1 metres) during the whole interval that the encoded output remains at 10,000 feet.3.12 Transitio
16、n Accuracy: When a transition from one encoded output to the next encoded output occurs, forboth increasing and decreasing altitude changes, the displayed pressure altitude shall be within 75 feet(22.86 metres) of the nominal pressure altitude for that transition point, corrected for the differences
17、 infeet as a result of the applied barometric setting and the value of the displayed pressure altitude based onthe pressure datum of 29.921 inches of mercury absolute (1013.25 millibars or 760 mm Hg Abs.).AS 8003-3 -3.12.1 Transition points for both the ON and OFF position for each output bit (chann
18、el) shall be checked in anincreasing altitude direction and the transition at the same points shall be checked in a decreasing altitude direction.3.12.2 Transition points for each bit (channel) shall be checked for all bits (channels) in accordance with themaximum operating altitude range defined fo
19、r the equipment.3.13 Fire Resistance: Except for small parts (such as knobs, fasteners, seals, grommets, and small electricalparts) that would not contribute significantly to the propagation of a fire, all combustible materials must be self extinguishing. When tested in an approved method, the avera
20、ge burn length must not exceed 3 inches (76.2 min) and the average flame time after removal of the flame source must not exceed 30 seconds. Drippings from the test specimen must not continue to flame for more than an average of 3 seconds after falling.4. PERFORMANCE UNDER STANDARD CONDITIONS4.1 Stan
21、dard Atmospheric Conditions: Unless otherside specified herein, all tests required shall be made atatmospheric conditions specified in paragraph 3.4 of DO-138.4.2 Attitude: Unless otherwise specified, herein, all tests shall be conducted with the instrument in its normaloperating position as defined
22、 in the manufacturers installation instructions.4.3 Performance Tests: The instrument shall be tested to demonstrate compliance with 3.8, 3.9, 3.10, 3.11and/or 3.12 as applicable to the code generating equipment.4.4. The performance tests specified above shall be conducted in accordance with the ope
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS80031974MINIMUMPERFORMANCESTANDARDFORAUTOMATICPRESSUREALTITUDEREPORTINGCODEGENERATINGEQUIPMENT 自动

链接地址:http://www.mydoc123.com/p-1025354.html