1、AEROSPACE STANDARDCopyright 1964 by Society of Automotive Engineers, Inc. Printed in U.S.A.SOCIETY OF AUTOMOTIVE ENGINEERS, Inc.485 LEXINGTON AVENUENEW YORK 17, N.Y.AS 654Issued 10-30-64RevisedSection8.3oftheSAETechnicalBoardrulesprovidethat:“Alltechnicalreports,includingstandardsapprovedandpractice
2、srecommended,areadvisoryonly.Theirusebyanyoneengagedinindustryortradeisentirelyvoluntary.ThereisnoagreementtoadheretoanySAEstandardorrecommendedpractice,andnocommitmenttoconformtoorbeguidedbyanytechnicalreport.Informulatingandapprovingtechnicalreports,theBoardanditsCommitteeswillnotinvestigateorcons
3、iderpatentswhichmayapplytothesubjectmatter.Prospectiveusersofthereportareresponsibleforprotectingthemselvesagainstliabilityforinfringementofpatents.”CABLE, SPECIAL PURPOSE, ELECTRICAL:WIRE, ELECTRICAL (IGNITION, HIGH-TENSION)1. SCOPE - This Aerospace Standard covers insulated, high-tension, shielded
4、, special purpose cable and unshielded electrical cable for ignition systems of internal combustion engines for aircraft.2. CLASSIFICATION - Cable shall be of the following types, grades, classes, and sizes, as specified (see 6.2).Type I - UnshieldedType II - ShieldedGrade A - Temperature range of +
5、250 to -35FGrade B - Temperature range of +450 to -65FGrade C - Temperature range of +250 to -65FGrade D - Temperature range of +600 to -65FClass 1 - Copper conductor (19 strands min.)Class 2 - Copper conductor (37 strands min.)Class 3 - Corrosion-resistant steel conductor (7 strands min.)Size 5 - 5
6、 millimeter outside diameterSize 7 - 7 millimeter outside diameter3. APPLICABLE DOCUMENTS3.1 The following specifications and standards of the issue in effect on the date of invitation for bids form a part of this standard.3.1.1 Federal SpecificationsO-A-548 - Antifreeze, Ethylene Glycol, InhibitedQ
7、Q-W-343 - Wire, Electrical and Nonelectrical, Copper (Uninsulated)3.1.2 Military SpecificationsMIL-J-5161 - Jet Fuel, RefereeMIL-A-6091 - Fluid; Anti-Icing (Isopropyl Alcohol)MIL-L-6082 - Lubricating Oil; Aircraft-EngineMIL-L-7808 - Lubricating Oil; Aircraft Turbine Engine Synthetic BaseMIL-I-13811
8、- Insulating Compound, Electrical, IgnitionMIL-F-13927 - Fungus Resistance Test; Automotive Electrical Components, General Specification forAS 654Issued 10-30-64RevisedCABLE, SPECIAL PURPOSE, ELECTRICAL:WIRE, ELECTRICAL (IGNITION, HIGH-TENSION)- 2 -3.1.3 Military StandardsMIL-Std-105 - Sampling Proc
9、edures and Tables for Inspection by AttributesMIL-Std-129 - Marking for Shipment and Storage3.2 Other Publications - The following documents form a part of this standard. Unless otherwise specified, the issue in effect on date of invitation for bids shall apply.Consolidated Freight Classification Ru
10、les and Container Specifications(Application for copies should be addressed to the Consolidated Classification Committee, 202 Chicago Union Station, Chicago 6, Illinois.)National Motor Freight Classification Rules and Container Specifications(Application for copies should be addressed to the Nationa
11、l Classification Board, 1424 Sixteenth Street, N. W., Washington 6, D.C.)4. REQUIREMENTS4.1 Qualification - Cable furnished under this standard shall be a product which has been tested and has passed the qualification tests specified herein. Subsequent to such qualification, no change shall be made
12、in materials, design, or construction of a considered type, grade, class, and size of cable without approval of the purchaser. Upon request by the purchaser, the manufacturer shall furnish a certified report showing results of complete qualification testing.4.2 Extension of Qualification - Qualifica
13、tion of cable of a given type, class, grade, and size submitted by a manufacturer may serve to qualify other cable or similar construction by the same manufacturer. Extension of qualification shall apply as follows:AS 654CABLE, SPECIAL PURPOSE, ELECTRICAL:WIRE, ELECTRICAL (IGNITION, HIGH-TENSION) Is
14、sued 10-30-64Revised- 3 -4.3 Materials - The materials used in the manufacture and testing of cable covered by this standard shall be as specified herein and in the applicable specification forming a part of this standard. Materials not specifically covered by this standard or the applicable specifi
15、cations shall be suitable for the intended purpose and free of defects which may affect the serviceability and appearance of the finished cable.4.4 Construction4.4.1 Type I (Unshielded Cable) - Type I cable shall consist of a stranded conductor, insulation, layer of braid and a sheath.4.4.2 Type II
16、(Shielded Cable) - Type II cable shall consist of Type I cable covered with a closely woven metal shielding.4.5 Components4.5.1 Conductor - The conductor shall be composed of wires of composition, quality, and tempers suitable for stranding and insulating. It shall be continuous throughout its lengt
17、h, without weld, splice, or joint, except that individual wires may be spliced as specified in 4.5.4. The conductor shall be uniformly circular in cross section, and shall be free of abrasions, kinks, and flats. The number of individual wires, the diameter of the wire and the diameter of the conduct
18、or shall be as specified in Table I.SAMPLEType IIGradeABCDClass123Size57QUALIFIEDTYPE I 7mm, 34 kilovolts.TABLE IIOutside Diameters, Type I Cable.Diameter(Nom)MillimetersActual(Min)InchesDiameter(Max)Inches570.1960.2700.2060.285AS 654CABLE, SPECIAL PURPOSE, ELECTRICAL:WIRE, ELECTRICAL (IGNITION, HIG
19、H-TENSION) Issued 10-30-64Revised- 7 -4.11.2.2 Dielectric Flaws - Type I cable and Type II cable before shielding is applied, shall be subjected to test specified in 5.3.1. After test, cable shall be inspected for flaws and for sections having insulation defects, which shall be removed from the cabl
20、e. Completed cable shall be certified as having passed the dielectric-flaws test, as specified, and that flaws and defective sections have been removed.4.11.2.3 Capacitance - The dielectric constant of the cable insulation shall be such that the capacitance of the completed cable does not exceed the
21、 values shown in Table III when tested as specified in 5.3.5.4.11.3 Resistance to Life Cycle Test - When subjected to tests specified in 5.3.7 (5.3.7.1 thru 5.3.7.7), Type I cable Type II cable before shield is applied shall show no evidence of sheath decomposition or other damage and shall meet the
22、 requirements of 4.11.2.1.4.11.4 Low-Temperature Resistance - When subjected to tests specified in 5.3.8, cable shall show no evidence of cracking, breaking, or separation and shall resist specified high potential without dielectric or other resultant failure.4.11.5 Hot-Oil Resistance - When subject
23、ed to tests specified in 5.3.9, cable shall show no evidence of cracking, rupture, decomposition, loss of specified dielectric strength, or other resultant damage, and cable diameter shall not swell more than 20% (30% for Grade B) (see 5.3.9.4).4.11.6 High-Temperature Resistance - When subjected to
24、tests specified in 5.3.10 (5.3.10.1 thru 5.3.10.2), cable shall show no sheath or insulation breakdown, and the conductor shall not be corroded.4.11.7 Flammability - When tested as specified in 5.3.12, no burning or charred particles shall fall from the cable, and the flame shall not travel along th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS6541964CABLESPECIALPURPOSEELECTRICALWIREELECTRICALIGNITIONHIGHTENSION 特殊 用途 电缆 电线 点火 电压 PDF

链接地址:http://www.mydoc123.com/p-1025229.html