SAE AS 6453-2013 Fire Containment Cover - Design Performance and Testing Requirements《火灾遏制遮盖物 设计 性能和试验要求》.pdf
《SAE AS 6453-2013 Fire Containment Cover - Design Performance and Testing Requirements《火灾遏制遮盖物 设计 性能和试验要求》.pdf》由会员分享,可在线阅读,更多相关《SAE AS 6453-2013 Fire Containment Cover - Design Performance and Testing Requirements《火灾遏制遮盖物 设计 性能和试验要求》.pdf(27页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2013 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/AS6453 AEROSPACE STANDARD AS6453 Issued 2013-08 Fire Containment Cover - Design,
5、Performance, and Testing Requirements RATIONALE This SAE Aerospace Standard (AS) specifies the design and performance criteria and testing methods applicable to fire containment covers intended to be used in conjunction with air cargo unit load devices in order to meet through oxygen depletion the f
6、ire containment regulations in certain civil transport aircraft cargo compartments. Throughout this Standard, the minimum essential criteria are identified by use of the key word “shall.” Recommended criteria are identified by use of the key word “should” and, while not mandatory, are considered to
7、be of primary importance in providing safe fire containment covers. Deviation from recommended criteria should only occur after careful consideration, extensive testing and thorough service evaluations have shown alternate methods to be satisfactory. The requirements of this Standard are expressed i
8、n the applicable SI units, with approximate inch-pound unit conversion between brackets. Where it is deemed necessary to use exact values, the SI units are to be used. SAE AS6453 Page 2 of 27 TABLE OF CONTENTS 1. SCOPE 3 2. NORMATIVE REFERENCES . 4 3. TERMS AND DEFINITIONS . 5 4. GENERAL REQUIREMENT
9、S . 6 4.1 Approval 6 4.2 Dimensions . 6 4.3 Materials 6 4.4 Weight . 7 4.5 Design . 7 4.6 Environment 8 4.7 Maintenance 9 5. PERFORMANCE 9 5.1 Components 9 5.1.1 Cover . 9 5.1.2 Pallet . 9 5.1.3 Net . 9 5.2 FCC Assembly 10 5.3 Allowable Damage 10 6. TESTING . 11 6.1 Materials Testing . 11 6.1.1 Flam
10、mability and Flame Penetration Tests 11 6.1.2 Puncture Test 13 6.1.3 U.V. and Humidity Test . 13 6.1.4 Abrasion Test 14 6.1.5 Fungus Test 14 6.1.6 Materials Testing Schedule . 14 6.2 FCC Assembly Test 15 7. MARKINGS . 17 8. MANUFACTURERS INSTRUCTIONS . 18 9. OPERATOR REQUIREMENTS 19 9.1 General . 19
11、 9.2 Operating Instructions . 19 9.3 Training and Qualification . 20 9.4 Quality Control 20 10. NOTES 20 SAE AS6453 Page 3 of 27 1. SCOPE 1.1 This SAE Aerospace Standard (AS), identical to ISO 14186, specifies the minimum design and performance criteria and testing methods of fire containment covers
12、 (FCCs) used either: a. in those cargo compartments of civil transport aircraft where they constitute one means of complying with applicable airworthiness regulations, or b. on a voluntary basis, when deemed appropriate by operators to improve fire protection in aircraft cargo compartments where air
13、worthiness regulations do not mandate their use. 1.2 The fire containment covers (FCCs) specified by this Standard are intended to be used to cover unitized cargo contained/restrained in an air cargo pallet and net assembly, for loading into aircraft main deck cargo compartments: a. either class F c
14、argo compartments according to CS-25 25.857(f) and AMC to CS-25.855 and 25.857, in accordance with 1.1 (a) above, b. or class B cargo compartments according to CS-25 25.857(b), JAS Part 3 or 14CFR Part 25 25.857(b), in accordance with 1.1 (b) above, c. or class E aircraft cargo compartments accordin
15、g to CS-25 25.857(e), JAS Part 3 or 14CFR Part 25 25.857(e), in accordance with 1.1 (b) above. NOTE 1: Though nothing prevents a fire containment cover (FCC) from being carried in a lower deck class C aircraft cargo compartment, it is not intended for this use since its fire containment capability w
16、ould be redundant with that of the aircrafts fire containment and suppression system, which it could hamper. 1.3 The fire containment covers specified by this Standard may be of two types: a. Type I: separate devices to be installed over a pallets load below a net approved for this purpose, or b. Ty
17、pe II: devices permanently attached to a pallet net approved for this purpose. 1.4 The unit load devices (pallet and net) used in conjunction with the fire containment cover are specified in this Standard only insofar as their flammability requirements are concerned. They are not otherwise specified
18、 in this Standard. NOTE 2: See Bibliography for applicable ULD airworthiness approval and general design standards. 1.5 This Standard does not cover fire containment of loose baggage or loose cargo loaded in bulk cargo compartments. 1.6 This Standard does not cover requirements for fire detection or
19、 suppression devices. The specified fire containment covers (FCCs) are passive devices. 1.7 The use of fire containment covers meeting the requirements of this Standard does not alone ensure flight safety. This Standard is based on the assumption that the approved fire containment covers will be ins
20、talled and checked prior to aircraft loading in accordance with appropriate operating instructions, by competent, suitably trained, personnel as defined for example in ISO 9001: 2008, 6.2.2 (see Reference 7 in Bibliography and 9.3). SAE AS6453 Page 4 of 27 2. NORMATIVE REFERENCES The following publi
21、cations form a part of this document to the extent specified herein. The latest issue of SAE publications shall apply. The applicable issue of other publications shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and references
22、cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. ISO 14186 Air Cargo - Fire Containment Covers- Design, performance and testing requirements. ISO 877 Plastics - Metho
23、ds of exposure to solar radiation - Part 1: General guidance ISO 4892 Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance ISO 4892 Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps ISO 7166 Aircraft - Rail and stud configurati
24、on for passenger equipment and cargo restraint ISO TR 8647 Environmental degradation of textiles used in air cargo restraint equipment ISO 10046 Aircraft - Methodology of calculating cargo compartment volumes ISO 10254 Air cargo and ground equipment - Vocabulary ISO 12236 Geotextiles and geotextile-
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS64532013FIRECONTAINMENTCOVERDESIGNPERFORMANCEANDTESTINGREQUIREMENTS 火灾 遏制 遮盖 设计 性能 试验 要求 PDF

链接地址:http://www.mydoc123.com/p-1025202.html