1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions.Copyright 2011 SAE International All rights reserved. No part of this pub
3、lication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970
4、(outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/AS6124AEROSPACESTANDARDAS6124 Issued 2011-12Aluminum Axially Swaged Fittings, Instal
5、lation and Inspection Procedure RATIONALEProcedure for assembling and inspection AS6116 type aluminum axially swaged fittings. 1. SCOPE 1.1 Purpose This procedure establishes the instructions to prepare tube ends, install and inspect axially swaged permanent tube fittings qualified to AS6116. This p
6、rocedure is applicable when specified on the engineering drawing or in the procurement document.2. APPLICABLE DOCUMENTS The following publications form a part of this document to the extent specified herein. The latest issue of SAE publications shall apply. The applicable issue of other publications
7、 shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exempti
8、on has been obtained. 2.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.orgAS6116 Aluminum Fittings, Axially Swaged Tube With Flareless Separable, Fluid System Up
9、to 1500 psi(10340 kPa) Maximum, Specification for 3. TOOLING AND GAGING VERIFICATION REQUIREMENTS 3.1 Tooling and Gaging Verification Prior to the listing of new gaging and tooling numbers in this procedure, the fitting/tooling system supplier shall demonstrate the interchangeability/capability by a
10、ssembling and gaging two sample fittings of each size of each manufacturer listed in the PRI-QPL-AS6116. The assembled fittings shall be tested to and pass the AS6116 impulse test requirements. Potential suppliers shall submit a plan to demonstrate interchangeability/capability to the Performance Re
11、view Institute(PRI), G-3 Fluid Distribution, Qualified Products Group (QPG), at PRI, 161 Thorn Hill Rd, Warrendale, PA 15086-7527. The QPG will grant approval for the suppliers numbers and name be added for the applicable tools or gages after demonstrating interchangeability/capability. SAE AS6124 P
12、age 2 of 12 4. GENERAL 4.1 Dimensions All dimensions in this specification are in inches. 4.2 Tube End Preparation The tube ends shall be cut square as defined in Figure 1. The tube ends , I.D. and O.D., shall be free of burrs. 4.3 Tube Condition - Sealing Area The tube sealing area shall be in acco
13、rdance with the tubing specification finish requirement. There shall be no scratches or other handling damage marks. This area shall be clean and free of paint, glue or any other foreign substance. 4.4 Tube Marking 4.4.1 Pre-Applied Tube End Marking At least one pair of marks, (positioning marks and
14、 inspection marks) as shown in Figure 1, shall be pre-applied with the given dimensions from Table 1 to each prepared tube end prior to fitting installation. A suitable permanent method such as ink stamp or electro-etch, etc. may be used. Should the tube ends be unmarked, the appropriate marks shall
15、 be applied using a tube marking gage as shown in Figures 2A and 2B, and using a suitable TEC (Trace Element Certified) permanent ink felt tipped pen. NOTE 1: Due to the possibility of ink contaminating tubing, inks which contain lead, 25 ppm maximum, or free halogens, 225 ppm combined maximum, shal
16、l not be used for marking. NOTE 2: See Table 2 for suppliers of marking gages. FIGURE 1 - POSITIONING AND INSPECTION TUBE MARKING SAE AS6124 Page 3 of 12 TABLE 1 - DIMENSIONS FOR INK STAMP OR ELECTRO-ETCH (IN) TABLE 2 APPROVED MARKING GAGES Dash Size Gage Number Supplier -04 DAT09AEMG1004 Cage Code
17、14798 -05 DAT09AEMG1005 Cage Code 14798 -06 DAT09AEMG1006 Cage Code 14798 -08 DAT09AEMG1008 Cage Code 14798 -10 DAT09AEMG1010 Cage Code 14798 -12 DAT09AEMG1012 Cage Code 14798 -16 DAT09AEMG1016 Cage Code 14798 -20 DAT09AEMG1020 Cage Code 14798 -24 DAT09AEMG1024 Cage Code 14798 NOTE: Approved Supplie
18、rs Cage Code 14798 Designed Metal Connections, dba Permaswage 14800 S. Figueroa, Gardena, California, 902484.4.2 Marking Gage Positioning The marking gage shall be bottomed on the end of the tube. FIGURE 2A - APPLICATION OF TUBE POSITIONING & INSPECTION MARKS USING APPROVED MARKING GAGES DashSize Di
19、a “A” Max.Inspection Mark Length(L1)PositioningMark Length (L2)D0.010E0.010Max. Out of Square “X”-04 .253 .350 .300 .320 .513 .003 -05 .3155 .350 .300 .455 .643 .003 -06 .378 .350 .300 .525 .792 .003 -08 .503 .350 .300 .695 .995 .005 -10 .629 .350 .300 .710 1.000 .005 -12 .754 .350 .300 .810 1.140 .
20、005 -16 1.004 .350 .300 1.080 1.510 .012 -20 1.255 .350 .300 1.305 1.785 .015-24 1.505 .350 .300 1.585 2.145 .015SAE AS6124 Page 4 of 12 FIGURE 2B - TUBE POSITIONING & INSPECTION MARKS AFTER REMOVING MARKING GAGE 4.4.3 Minimum Straight Tube Length to Bend In the case of swaging a fitting on bent tub
21、ing, the installation marks shall be within the minimum straight tube length to bend based on the orientation of the tube bend with respect to the swage tool. Figure 3 shows the two different orientations for a typical 90 degree bent tube. Minimum straight tube lengths to bend are shown in Table 3 f
22、or each orientation (configuration). FIGURE 3 INSTALLATION OF BENT TUBEPositioning Mark Inspection Mark SAE AS6124 Page 5 of 12 TABLE 3 MINIMUM STRAIGHT TUBE LENGTH (L) TO BEND Dash Size Configuration I Configuration II -04 2.64 .94 -05 2.57 1.07 -06 2.82 1.23 -08 2.92 1.46 -10 2.85 1.58 -12 3.56 1.
23、65 -16 3.65 2.05 -20 3.99 2.30 -24 4.37 2.71 4.4.4 Minimum Port Separation Distance In the case of swaging fittings on parallel tubing, it is recommended to maintain the minimum port separation distance to engage the swage tool on two parallel fittings without interference for proper swaging. Figure
24、 4 shows the configuration of two fittings in parallel. Table 4 shows the recommended minimum port separation distance M for various size combinations of Aluminum Axially Swaged Fitting series (i.e. a 04 fitting next to a 10 fitting). FIGURE 4 MINIMUM PORT SEPARATION DURING INSTALLATION OF PARALLEL
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS61242011ALUMINUMAXIALLYSWAGEDFITTINGSINSTALLATIONANDINSPECTIONPROCEDURE 安装 检查 程序 使用 铝制 轴向 配件 PDF

链接地址:http://www.mydoc123.com/p-1025096.html