1、AEROSPACE STANDARDCABLE, HIGH PERFORMANCE, 4 PAIR,SHIELDED, 100 OHM, 200 C, ETHERNET 1000 BASE TAS6070/5Copyright 2017 SAE InternationalAll rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical
2、, photocopying, recording, or otherwise, without the prior written permission of SAE.TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA)Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgISSUED2016-04REVISED2017-02THI
3、RD ANGLE PROJECTIONCUSTODIAN: AE-8/AE-8DREV. AFEDERAL SUPPLY CLASS6145AS6070/5SHEET 1 OF 5REV.APROCUREMENT SPECIFICATION: AS6070SAE Technical Standards BoardRules providethat:“This reportis publishedby SAE to advance thestateoftechnical andengineering sciences. The useofthis reportis entirely volunt
4、ary, and its applicability and suitability forany particularuse, includingany patent infringement arising therefrom, is thesole responsibility of theuser.”SAE reviews eachtechnical reportatleastevery fiveyears at whichtime it may berevised, reaffirmed, stabilized, or cancelled. SAEinvites your writt
5、en comments and suggestions.SAE values your input. To provide feedback on thisTechnical Report, please visit http:/standards.sae.org/AS6070/5ARATIONALEREVISION IS REQUIRED TO CORRECT THE ATTENUATION REQUIREMENTS FOR 24 AWG CONDUCTORS AT 80 METERS AND 26 AWG CONDUCTORS AT 65 METERS AND CHANGES TITLE
6、TO DELETE “ETHERNET 10G BASE T TO 33 METERS”.NOTICETHE COMPLETE REQUIREMENTS FOR PROCURING THE PRODUCT DESCRIBED HEREIN SHALL CONSIST OF THIS DOCUMENT AND THE LATEST ISSUE OF AS6070.FIGURE 1 - FOUR PAIR CONFIGURATION (DESIGN SHOWN IS NOTIONAL)1.0 CONSTRUCTION DETAILSTABLE 1COMPONENT MATERIAL REQUIRE
7、MENTCONDUCTOR 24 AWG 19X36 SILVER PLATED COPPER OR COPPER ALLOY 1/26 AWG 19X38 SILVER PLATED COPPER ALLOY 2/ .0254 INCH MAXIMUM.0204 INCH MAXIMUMINSULATION FLUOROPOLYMER 24 AWG 26 AWG .060 INCH NOMINAL.050 INCH NOMINALINSULATED CONDUCTOR COLORSPAIR 1: WHITE/BLUE COPPER ALLOY SCA OF AS29606 TABLES 3
8、AND 4.2/ SIZE 26 CONDUCTOR SHALL BE ANNEALED COPPER TYPE SCC; COPPER ALLOY SCA OF AS29606 TABLES 3 AND 4. 3/ PAIRS CONTAINING SOLID WHITE WIRE NOT FOR U.S. DEPARTMENT OF DEFENSE (NAVY) USE.CONDUCTORINSULATIONPAIR SHIELDOUTER SHIELDJACKETFILLER OR SEPARATER(CONFIGURATION OPTIONAL)DRAIN WIRE (OPTIONAL
9、)AEROSPACE STANDARD AS6070/5SHEET 2 OF 5REV.ACABLE, HIGH PERFORMANCE, 4 PAIR,SHIELDED, 100 OHM, 200 C, ETHERNET 1000 BASE TTABLE 2LIGHT/STANDARD CABLE REQUIREMENTSCABLE CONDUCTOR WEIGHT DIAMETERLIGHT24 AWG26 AWG45.0 POUNDS/1000 FEET MAXIMUM35.0 POUNDS/1000 FEET MAXIMUM.270 INCH MAXIMUM.230 INCH MAXI
10、MUMSTANDARD24 AWG26 AWG57.0 POUNDS/1000 FEET MAXIMUM45.0 POUNDS/1000 FEET MAXIMUM.300 INCH MAXIMUM.250 INCH MAXIMUM2.0 CABLE CONFIGURATION: CABLE CONSTRUCTION SHALL BE IN ACCORDANCE WITH TABLE 1. THE CABLE SHALL HAVE THEFOLLOWING OPERATING CHARACTERISTICS AND DESIGN REQUIREMENTS:2.1 CONTINUOUS WORKI
11、NG VOLTAGE: 60 V (SEE NOTE 1).2.2. OPERATING FREQUENCY: 1 TO 250 MHz.2.3 OPERATING TEMPERATURE RATING: -55 C MINIMUM TO +200 C MAXIMUM.2.4 CONDUCTOR DCR (PRIOR TO INSULATING) AT 20 C:24 AWG ANNEALED COPPER 24.3 OHMS/1000 FEET MAXIMUM24 AWG COPPER ALLOY (HIGH STRENGTH) 28.4 OHMS/1000 FEET MAXIMUM26 A
12、WG COPPER ALLOY (HIGH STRENGTH) 44.8 OHMS/1000 FEET MAXIMUM2.5 CABLE MINIMUM BEND RADIUS: 7 TIMES DIAMETER3.0 PERFORMANCE REQUIREMENTS ARE IN ACCORDANCE WITH AS6070 UNLESS OTHERWISE SPECIFIED.3.1 LIFE CYCLE: OVEN TEMPERATURE: 200 C 5 C. WIRE INSULATION SHALL NOT SHRINK MORE THAN .090 INCH AND JACKET
13、 INSULATION SHALL NOT SHRINK MORE THAN .150 INCH. NO MANDREL OR WEIGHTS ARE REQUIRED DURING THE LIFE CYCLE TEST. PERFORM THE BEND TEST AFTER OVEN AGING. JACKET AND COMPONENT WIRES SHALL MEET DIELECTRIC WITHSTANDREQUIREMENTS.3.2 BEND: REQUIRED AFTER LIFE CYCLE AND FLUID IMMERSION. THE JACKET AND COMP
14、ONENT WIRES SHALL MEET DIELECTRIC WITHSTAND REQUIREMENTS. MANDREL SIZE: 10 TIMES CABLE DIAMETER (10%). WEIGHTS: NONE. WRAPCABLE BY HAND AROUND MANDREL WITH SUFFICIENT TENSION TO HOLD CABLE FIRMLY AGAINST MANDREL.3.3 BLOCKING: OVEN TEMPERATURE: 200 C 5 C; MANDREL SIZE: 10 TIMES CABLE DIAMETER (10%).
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS60705A2017CABLEHIGHPERFORMANCE4PAIRSHIELDED100OHM200ETHERNET1000BASETPDF

链接地址:http://www.mydoc123.com/p-1025064.html