SAE AS 5756 1A-2011 CABLE POWER ELECTRICAL 600 VOLTS PORTABLE SINGLE CONDUCTOR NON-OZONE RESISTANT《耐非臭氧的600 V便携式单芯电力电缆》.pdf
《SAE AS 5756 1A-2011 CABLE POWER ELECTRICAL 600 VOLTS PORTABLE SINGLE CONDUCTOR NON-OZONE RESISTANT《耐非臭氧的600 V便携式单芯电力电缆》.pdf》由会员分享,可在线阅读,更多相关《SAE AS 5756 1A-2011 CABLE POWER ELECTRICAL 600 VOLTS PORTABLE SINGLE CONDUCTOR NON-OZONE RESISTANT《耐非臭氧的600 V便携式单芯电力电缆》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、 AEROSPACE STANDARD CABLE, POWER, ELECTRICAL, 600 VOLTS, PORTABLE, SINGLE CONDUCTOR, NON-OZONE RESISTANT AS5756/1 Copyright 2017 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic,
2、 mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org ISSUED 2004-06RE
3、VISED2011-11REAFFIRMED 2017-12THIRD ANGLE PROJECTION CUSTODIAN: AE-8D REV.A FEDERAL SUPPLY CLASS 6145 AS5756 /1 SHEET 1 OF 2 REV. A PROCUREMENT SPECIFICATION: AS5756 SAE Technical Standards Board Rules provide that: “This report is published by SAEtoadvance thestate of technicaland engineering scien
4、ces. The useof this report is entirely voluntary, and its applicability andsuitability for any particularuse, includingany patent infringement arisingtherefrom,is the sole responsibility of theuser.” SAE reviews eachtechnical reportatleast every fiveyears at whichtime it may be revised, reaffirmed,
5、stabilized, or cancelled. SAE invites your written comments and suggestions.SAE values your input. To provide feedback on this Technical Report, please visit http:/standards.sae.org/AS5756/1A RATIONALE UPDATE REFERENCES NOTICE THE REQUIREMENTS FOR PROCURING THE PRODUCT DESCRIBED HEREIN SHALL CONSIST
6、 OF THIS SPECIFICATION SHEET AND THE LATEST ISSUE OF: SAE AS5756. FIGURE 1 - CONDUCTOR EXAMPLE REQUIREMENTS (SEE AS5756 AND TABLE 1): CONSTRUCTION FIRST - COPPER CONDUCTOR, SEE TABLE 1 OF AS5756 FOR REQUIREMENTS, SIZES 10 AWG AND SMALLER SHALL BE TIN-COATED, SIZES 8 AWG AND LARGER SHALL BE UNCOATED.
7、 SECOND - SEPARATOR, REQUIRED WHERE UNCOATED CONDUCTORS ARE USED, OPTIONAL WHERE TIN-COATED CONDUCTORS ARE USED. THIRD - INSULATION OF SYNTHETIC OR NATURAL RUBBER (SEE TABLE 1 FOR THICKNESS), COLORED BLACK. FOURTH - JACKET OF SYNTHETIC OR NATURAL RUBBER (SEE TABLE 1 FOR THICKNESS), COLORED BLACK. CA
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS57561A2011CABLEPOWERELECTRICAL600VOLTSPORTABLESINGLECONDUCTORNONOZONERESISTANT 臭氧 600 便携式 电力电缆 PDF

链接地址:http://www.mydoc123.com/p-1024939.html