SAE AS 5692 1-2007 ARC FAULT CIRCUIT BREAKER TRIP FREE PUSH-PULL FUSIBLE LINK DESIGN 2 -15 AMPS TYPE I《I型电流2~1 2~15A熔线设计推挽式自动断路的电弧故障断路器》.pdf
《SAE AS 5692 1-2007 ARC FAULT CIRCUIT BREAKER TRIP FREE PUSH-PULL FUSIBLE LINK DESIGN 2 -15 AMPS TYPE I《I型电流2~1 2~15A熔线设计推挽式自动断路的电弧故障断路器》.pdf》由会员分享,可在线阅读,更多相关《SAE AS 5692 1-2007 ARC FAULT CIRCUIT BREAKER TRIP FREE PUSH-PULL FUSIBLE LINK DESIGN 2 -15 AMPS TYPE I《I型电流2~1 2~15A熔线设计推挽式自动断路的电弧故障断路器》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 AEROSPACE STANDARD ARC FAULT CIRCUIT BREAKER, TRIP FREE, PUSH-PULL, FUSIBLE LINK DESIGN, 2 -15 AMPS, TYPE I AS5692/1Copyright 2014 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electron
2、ic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org ISSUED 2007-0
3、1REAFFIRMED 2014-09 THIRD ANGLE PROJECTION CUSTODIAN: AE-8/AE-8B1 FEDERAL SUPPLY CLASS 5925 AS5692/1 SHEET 1 OF 5 PROCUREMENT SPECIFICATION: AS5692SAE Technical Standards Board Rules provide that: “This report ispublishedby SAE toadvance thestate of technicalandengineeringsciences.The useofthis repo
4、rtisentirelyvoluntary, andits applicability and suitability forany particular use,including any patent infringement arising therefrom, isthe soleresponsibilityofthe user.”SAE reviews eachtechnicalreport at least every five years at which time itmay berevised,reaffirmed, stabilized, orcancelled. SAE
5、invites yourwrittencomments andsuggestions. SAE values your input. To provide feedbackon this Technical Report, please visit http:/www.sae.org/technical/standards/PRODCODE RATIONALE AS5692/1 HAS BEEN REAFFIRMED TO COMPLY WITH THE SAE FIVE-YEAR REVIEW POLICY. THE REQUIREMENTS FOR PROCURING THE PRODUC
6、T DESCRIBED HEREIN SHALL CONSIST OF THIS SPECIFICATION SHEET AND THE LATEST ISSUE OF: SAE AS5692. FIGURE 1 REF. LINE A REPRESENTS THE LOCATION OF THE INTERFACE BETWEEN THE AFCB AND THE PANEL. DIMENSIONS REFERENCED FROM “REF. LINE A” ARE THE DIMENSION FROM THE BACK OF THE PANEL TO THE DIMENSIONED FEA
7、TURE. AEROSPACE STANDARD AS5692/1 SHEET 2 OF 5 ARC FAULT CIRCUIT BREAKER, TRIP FREE, PUSH-PULL, FUSIBLE LINK DESIGN, 2 -15 AMPS, TYPE I TABLE 1 - ELECTRICAL AND MECHANICAL CHACTERISTICS ENDURANCE CYCLES OPERATING FORCE (LB) RESISTIVE INDUCTIVE DASH NO. NOMINAL AMPERAGE RATING (A) VOLTAGE DROP MAX (V
8、) WEIGHT MAX (LB) PULLOUT RESET AC AC MECH NO LOAD CYCLES 2- 2.5 (2-) 0.75 3 3 0.64 5 5 0.50 7- 7.5 (7-) 0.30 10 10 0.28 15 15 0.25 .090 1-5 1-5 5,000 2,500 10,000 TABLE 2 - DETAIL CALIBRATION REQUIREMENTS OVERLOAD TRIP TIME IN SECS AT PERCENT RATED CURRENT 25 C AMBIENT EFFECT ON CALIBRATION AT PERC
9、ENT RATED CURRENT +25 C +71 C -55 C NOMINAL AMPERAGE RATING (A) 200% 500% 1000% 115% 138% 90% 138% 115% 165% 2- 3 5 7- 10 15 4 TO 20 .4 TO 2 0.1 TO 0.53 MUST HOLD - 1 HOURMIN MUST TRIP - 1 HOUR MAX MUST HOLD - 1 HOURMIN MUST TRIP - 1 HOUR MAX MUST HOLD - 1 HOURMIN MUST TRIP - 1 HOUR MAX AMBIENT TOLE
10、RANCE 2 C TABLE 3 - INTERRUPTING CAPACITY (AMPERES) REQUIREMENTS TEST DESIGNATION PER AS5692 NOMINAL AMPERAGE RATING (A) A B C 2- 3 5 7- 10 2800 2800 15 2000 2000 (a) 1,500 (b) 750 TABLE 4 - ENVIRONMENTAL PERFORMANCE MAX. OPERATING ALTITUDE 70,000 FEET OPERATING AMBIENT TEMPERATURE RANGE (-)55 C (+)
11、71 C VIBRATION IN ACCORDANCE WITH AS5692 SINE - REQUIRED HIGH SINE - (OPTIONAL) RANDOM - (OPTIONAL) SHOCK 50 G, MIL-STD-202, METHOD 213, CONDITION A ACCELERATION 10 G TABLE 5 - FUSE TIME MAXIMUM CIRCUIT BREAKER LINKS SEPARATION (FUSING) TIMES FOR GIVEN OVERLOAD CURRENT (SECONDS) NOMINAL AMPERAGE RAT
12、ING (A) 400% 500% 600% 700% 800% 900% 1000% 2- - - 34 20 13 9.0 6.0 3 - - 34 20 13 9.0 6.0 5 - 95 36 18 10 6.0 3.5 7- 69 28 14 8 4.5 3.5 2.0 10 322 110 30 15.5 7.0 4.0 2.5 15 78 25 14 8.0 5.0 3.0 2.0 AEROSPACE STANDARD AS5692/1 SHEET 3 OF 5 ARC FAULT CIRCUIT BREAKER, TRIP FREE, PUSH-PULL, FUSIBLE LI
13、NK DESIGN, 2 -15 AMPS, TYPE I REQUIREMENTS: 1. TWO GROUNDING METHODS SHALL BE PROVIDED AS FOLLOWS: a. THE TOP SURFACE OF THE AFCB (IN LOCATION SPECIFIED IN DRAWING) SHALL PROVIDE A GROUNDING SURFACE WHICH MUST MEET THE REQUIREMENTS OF DISSIMILAR METALS (MIL-STD-889) WHEN GROUNDED TO A BARE ALUMINUM
14、PANEL. b. THE GROUND SOCKET SHALL BE APPROPRIATELY SIZED TO ACCEPT A PIN CONTACT PER M39029/1-101 (20 GAGE). THE SOCKET SHALL MEET CONTACT RESISTANCE, CONTACT INSERTION AND REMOVAL FORCES, CONTACT RETENTION, CONTACT WALKOUT, CONTACT RESISTANCE TO PROBE DAMAGE, AND SALT SPRAY (CORROSION) PERFORMANCE
15、REQUIREMENTS OF AS81714. A PIN CONTACT PER M39029/1-101 (20 GAGE) AND WIRE ASSEMBLY SHALL BE INSTALLED IN THE SOCKET, AND THE DIELECTRIC WITHSTANDING VOLTAGE TEST OF AS5692 SHALL BE PERFORMED BETWEEN THE WIRE AND THE MUTUALLY INSULATED METAL PARTS OF THE DUT, AND THE RESULTS MUST MEET THE DIELECTRIC
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS569212007ARCFAULTCIRCUITBREAKERTRIPFREEPUSHPULLFUSIBLELINKDESIGN215AMPSTYPEII 电流 12 15 设计 推挽式 自动

链接地址:http://www.mydoc123.com/p-1024921.html