SAE AS 5382 5A-2007 CABLE FIBER OPTIC MULTI-MODE 50 125 450 GRADED INDEX HERMETIC COATED TIGHT BUFFER《密封涂层紧包缓冲层50 125 450μm分级指数多模光纤光缆》.pdf
《SAE AS 5382 5A-2007 CABLE FIBER OPTIC MULTI-MODE 50 125 450 GRADED INDEX HERMETIC COATED TIGHT BUFFER《密封涂层紧包缓冲层50 125 450μm分级指数多模光纤光缆》.pdf》由会员分享,可在线阅读,更多相关《SAE AS 5382 5A-2007 CABLE FIBER OPTIC MULTI-MODE 50 125 450 GRADED INDEX HERMETIC COATED TIGHT BUFFER《密封涂层紧包缓冲层50 125 450μm分级指数多模光纤光缆》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 AEROSPACE STANDARD CABLE, FIBER OPTIC, MULTI-MODE, 50/125/450 m, GRADED INDEX, HERMETIC COATED, TIGHT BUFFER AS5382/5 Copyright 2007 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electr
2、onic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org ISSUED 2004-04
3、REVISED 2007-09 THIRD ANGLE PROJECTION CUSTODIAN: SAE AE-8/AE-8D REV. A FEDERAL SUPPLY CLASS6010 AS5382/5 SHEET 1 OF 4 REV. A PROCUREMENT SPECIFICATION: NONESAE TechnicalStandards Board Rules provide that: “This report is published by SAE toadvance thestate of technical andengineering sciences.The u
4、se of thisreport is entirely voluntary, andits applicabilityandsuitability forany particularuse,including any patent infringement arising therefrom, is thesole responsibility oftheuser.” SAE reviews each technical report at least every five yearsat which time it may be reaffirmed, revised, orcancell
5、ed.SAE invites yourwritten commentsandsuggestions.RATIONALE REVISED TO MAKE CABLE MORE PRODUCIBLE. FIGURE 1 - CABLE CONFIGURATION 1. Construction Description 1.1 Optical Fiber Dimensions and Materials Core Diameter: 50 m 3.0 m (0.00195 in 0.00012 in) Core Material: Graded Index Silica Glass Cladding
6、 Diameter: 125 m 2 m (0.0049 in 0.00008 in) Cladding Material: Silica Glass Core to Cladding Ellipticity: 3% maximum Core to Cladding Offset: 3 m maximum Hermetic Coated: Yes Coating Diameter: 450 m 25 m (0.0177 in 0.001 in) Coating Material: Silicone Coating Concentricity: 65% minimum 125 MICRON OD
7、 HERMETIC COATED GLASS FIBER SILICONE BUFFER ETFE UPJACKET BRAIDED PARA-ARAMID FIBER STRENGTH MEMBER 1.8 MM ETFE OUTER JACKET AEROSPACE STANDARD CABLE, FIBER OPTIC, MULTI-MODE, 50/125/450 m, GRADED INDEX, HERMETIC COATED, TIGHT BUFFER AS5382/5 SHEET 2 OF 4 REV. A 1.2 Cable Dimensions and Materials U
8、pjacket Diameter: 900 m 50 m (0.0354 in 0.002 in) Upjacket Material: Ethylene-Tetrafluoroethylene Copolymer (ETFE) Strength Member: Braided Para-Aramid Fiber Yarn Size: 380 Denier Number of Ends: 16 Braid Picks/Inch: 14.5 Outer Jacket Diameter: 1800 m 100 m (0.0709 in max 0.039 in max) Outer Jacket
9、Material: Ethylene-Tetrafluoroethylene Copolymer (ETFE) Outer Jacket Concentricity: 6% of Jacket Outer Diameter 1.3 Cable Performance Operational Mode: Multi-mode Temperature Rating: -55 to +165 C Storage Temperature: -55 to +85 C Outer Jacket Color: Orange Finished Cable Weight: 4.0 kg/km maximum 2
10、. Optical Fiber Requirements Maximum Attenuation: 6 dB/km 850 nm, 4 dB/km 1300 nm Numerical Aperture: 0.20 0.02 Fiber Tensile Proof Test: 200,000 psi minimum Bandwidth 400 MHz-km 850 nm & 1300 nm 3. Environmental Fluid Immersion: See Table 1 for test fluid listing. Freezing Water Immersion: 0.5 dB c
11、hange in optical transmittance during the test with 0.5 dB permanent change after test Humidity Resistance: 0.5 dB change in optical transmittance during the test with 0.5 dB permanent change after test Wicking: Water Penetration of 88.5 mm maximum Fungus Resistance: Fungus inert per MIL-HDBK-454 Gu
12、ideline 4 Blocking: No areas of localized adhesion 4. Mechanical Cold Bend: 0.5 dB change in optical transmittance after test Cyclic Flex: 0.5 dB change in optical transmittance during the test with 0.5 dB permanent change after test Test temps: -55 C, +25 C, +150 C Impact Resistance: 0.5 dB change
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS53825A2007CABLEFIBEROPTICMULTIMODE50125450GRADEDINDEXHERMETICCOATEDTIGHTBUFFER 密封 涂层 缓冲 50125450

链接地址:http://www.mydoc123.com/p-1024835.html