1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2017 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/standards.sae.org/AS31571 AEROSPACE STANDARD AS31571 Issued 2012-08 Reaffirmed 2017-10 Supersedes MS3157 Insert A
5、rrangements for AS81659 Series 1 and 2 Electrical Connectors FSC 5935 RATIONALE AS31571 has been reaffirmed to comply with the SAE Five-Year Review policy. NOTICE The initial SAE publication of this document was taken directly from U.S. Military Standard MS3157D. This SAE Standard may retain the sam
6、e part numbers established by the original military document. Any requirements associated with Qualified Products Lists (QPL) may continue to be mandatory for DoD contracts. Requirements relating to QPLs have not been adopted by the SAE for this Standard and are not part of this SAE document. 1. SCO
7、PE 1.1 Scope This standard gives the dimensional requirements for insert arrangements used in AS81569 Series 1 and 2 electrical connectors. 2. REFERENCES 2.1 Applicable Documents The following publications form a part of this document to the extent specified herein. The latest issue of SAE publicati
8、ons shall apply. The applicable issue of the other publications shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and references cited herein, the text of this document takes precedence. Nothing in this document, however, super
9、sedes applicable laws and regulations unless a specific exemption has been obtained. 2.1.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org. AS81659 Connectors, E
10、lectrical, Rectangular, Crimp Contacts, General Specification For 2.2 Order of Precedence In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regula
11、tions unless a specific exemption has been obtained. 2.3 Definitions The terms used in this standard are generally accepted by the electrical and electronics industries and commonly used in electrical connector engineering practice. 3. GENERAL REQUIREMENTS Not applicable. 4. DETAIL REQUIREMENTS 4.1
12、Dimensions Dimensions shall be in accordance with this standard and the following dimensional data: a. Dimensions are basic and are in inches. See AS81659 intermateability control dimensions for tolerance. b. Metric equivalents (to the nearest 0.01 mm) are given for general information only and are
13、based upon 1 in = 25.4 mm. c. Dimensions and markings shown are for engaging face of pin insert. Socket insert is opposite. 5. NOTES (This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.) 5.1 Intended Use This standard contains requirements
14、for insert arrangements to be used in AS815659 Series 1 and 2 Electrical Connectors. 5.2 Data Requirements No data is required by this standard. 5.3 Issue of DODISS When this standard is used in acquisition, the applicable issue of the DODISS must be cited in the solicitation. SAE INTERNATIONAL AS31
15、571 Page 2 of 14_ INSERTS FIGURE 1 - 26 POSITION INSERT ARRANGEMENT 26 SIZE 16 CONTACTS SHELL DESIGNATOR A SERVICE RATING B FIGURE 2 - 40 POSITION INSERT ARRANGEMENT 40 SIZE 20 CONTACTS SHELL DESIGNATOR A SERVICE RATING B SAE INTERNATIONAL AS31571 Page 3 of 14_ FIGURE 3 - 45 POSITION INSERT ARRANGEM
16、ENT 45 SIZE 20 CONTACTS SHELL DESIGNATOR A SERVICE RATING B FIGURE 4 - 57 POSITION INSERT ARRANGEMENT 57 SIZE 20 CONTACTS SHELL DESIGNATOR A SERVICE RATING B SAE INTERNATIONAL AS31571 Page 4 of 14_ FIGURE 5 - 67 POSITION INSERT ARRANGEMENT 64 SIZE 20 CONTACTS 3 SIZE 16 CONTACTS (POSTIONS 3, 4 AND 5)
17、 SHELL DESIGNATOR A SERVICE RATING A FIGURE 6 - 124 POSITION INSERT ARRANGEMENT 124 SIZE 20 CONTACTS SHELL DESIGNATOR B SERVICE RATING A SAE INTERNATIONAL AS31571 Page 5 of 14_ FIGURE 7 - 106 POSITION INSERT ARRANGEMENT 106 SIZE 22 CONTACTS SHELL DESIGNATOR A SERVICE RATING A FIGURE 8 - C2 POSITION
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS315712012INSERTARRANGEMENTSFORAS81659SERIES1AND2ELECTRICALCONNECTORSAS81659 系列 电气 连接 器用 部署 PDF

链接地址:http://www.mydoc123.com/p-1024027.html