SAE AS 29606-2014 Wire Electrical Stranded Uninsulated Copper Copper Alloy or Aluminum or Thermocouple Extension General Specification For《未绝缘铜 铜合金或者铝或者热电偶补偿的搓制电线 通用规格》.pdf
《SAE AS 29606-2014 Wire Electrical Stranded Uninsulated Copper Copper Alloy or Aluminum or Thermocouple Extension General Specification For《未绝缘铜 铜合金或者铝或者热电偶补偿的搓制电线 通用规格》.pdf》由会员分享,可在线阅读,更多相关《SAE AS 29606-2014 Wire Electrical Stranded Uninsulated Copper Copper Alloy or Aluminum or Thermocouple Extension General Specification For《未绝缘铜 铜合金或者铝或者热电偶补偿的搓制电线 通用规格》.pdf(35页珍藏版)》请在麦多课文档分享上搜索。
1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions.Copyright 2014 SAE International All rights reserved. No part of this pub
3、lication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970
4、(outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/AS29606AEROSPACESTANDARDAS29606Issued 2014-06 Wire, Electrical, Stranded, Uninsulate
5、d Copper, Copper Alloy, or Aluminum, or Thermocouple Extension, General Specification For RATIONALESAE version of MIL-DTL-29606, which includes enhancements for quality assurance provisions and establishes qualification requirements for the coated copper and copper-alloy conductors furnished under t
6、he specification. 1. SCOPE This specification covers concentric lay stranded and rope-lay stranded round electrical conductor fabricated from copper, copper alloy or aluminum. This specification also covers thermocouple extension conductor fabricated from nickel/chromium or nickel/aluminum/manganese
7、. The conductors in this specification are suitable for use in insulated wires used in aerospace and other applications. 1.1 Classification Stranded conductors are classified herein. The classifications are as follows: Conductor Material Conductor Coating Conductor Stranding Conductor Dimensions 1.1
8、.1 Part or Identifying Number (PIN) PINS to be used for the wire acquired to this specification are created as in the following example: M29606 -20 -SCC -GPConductor Diameter Tolerance (See 1.1.1.4)Conductor Material and Coating (See 1.1.1.3)Conductor Size (See 1.1.1.2)Basic Part Number (See 1.1.1.1
9、)The above conductor is a size 20 conductor of silver coated annealed copper conductor with general purpose diameter control.SAE INTERNATIONAL AS29606 Page 2 of 35 1.1.1.1 Basic Part Number The conductor part number consists of the letter “M,” the basic number of the applicable specification and the
10、 applicable alpha-numeric characters formulated in the example (see 1.1.1). 1.1.1.2 Conductor Size A one- or two-digit designator from Table 4 is used to designate the conductor size. 1.1.1.3 Conductor Material and Coating Designator An alphabetic designator from Table 3 is used to designate the con
11、ductor material and conductor coating. 1.1.1.4 Conductor Diameter Tolerance The conductor diameter dimensional tolerance is designated as follows: GP - General Purpose (see Table 4) SD - Small Diameter (see Table 4) NOTE: The GP conductors are inactive for new design for copper and copper alloy cond
12、uctors. All conductors without a distinct diameter tolerance (GP or SD) are designated as general purpose (GP) diameter tolerance conductors. 2. REFERENCES 2.1 Applicable Documents The following publications form a part of this document to the extent specified herein. The latest issue of SAE publica
13、tions shall apply. The applicable issue of other publications shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and references cited herein, the text of this document takes precedence. Nothing in this document, however, superse
14、des applicable laws and regulations unless a specific exemption has been obtained. 2.1.1 U.S. Government Publications Available from DLA Document Services, Building 4/D, 700 Robbins Avenue, Philadelphia, PA 19111-5094, Tel: 215-697-6396, http:/quicksearch.dla.mil/.2.1.1.1 Federal Standard FED-STD-22
15、8 Cable and Wire, Insulated; Methods of Testing 2.1.1.2 Department of Defense Standards MIL-STD-202 Electronic and Electrical Component Parts MIL-STD-2223 Test Methods for Insulated Electric Wire SD-6 Provisions for Governing Qualification 2.1.1.3 Department of Defense Specifications MIL-C-3993 Copp
16、er and Copper-Base Alloy Mill Products; Packaging of SAE INTERNATIONAL AS29606 Page 3 of 35 2.1.2 Non-Government Publications 2.1.2.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outsi
17、de USA), www.sae.org.AIR4487 Investigation of Silver Plated Conductor Corrosion (Red Plague) ARP6400 Recommended Practice for Processing and Handling Wire and Cable with Silver Plated Conductors and ShieldsAS9100 Quality Management Systems - Requirements for Aviation, Space and Defense Organizations
18、 2.1.2.2 ASQ Publications Available from American Society for Quality, 600 North Plankinton Avenue, Milwaukee, WI 53203, Tel: 800-248-1946 (United States or Canada), 001-800-514-1564 (Mexico) or +1-414-272-8575 (all other locations), www.asq.org.ASQ Z1.4 Sampling Procedures and Tables for Inspection
19、 by Attributes 2.1.2.3 ASTM Publications Available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, Tel: 610-832-9585, www.astm.org.ASTM B230/B230M Aluminum 1350 - H19 Wire for Electrical Purposes (DoD adopted) ASTM B263 Determination of Cross-Sectiona
20、l Area of Stranded Conductors (DoD adopted) ASTM B286 Copper Conductors for Use In Hookup Wire for Electronic Equipment (DoD adopted) ASTM B298 Wire, Copper, Silver-Coated Soft or Annealed (DoD adopted) ASTM B355 Nickel-Coated Soft or Annealed Copper Wire (DoD adopted) ASTM B624 Wire Copper Alloy, H
21、igh Strength, High Conductivity, for Electronic Application (DoD adopted) ASTM B961 Standard Specification for Silver Coated Copper and Copper Alloy Stranded Conductors for Electronic Space Application ASTM B965 Standard Specification for High Performance Tin-Coated Annealed Copper Wire Intended for
22、 Electrical and Electronic Application for Solderability ASTM E230/E203M Standard Specification and Temperature Electromotive Force (EMF) Tables for Standardized Thermocouples2.1.2.4 TechAmerica Publications Available from TechAmerica, 1001 19th St. North, 20th Floor, Arlington, VA 22209, Tel: 202-6
23、82-9110, www.techamerica.org.EIA-557 Statistical Process Control Systems (DoD adopted) SAE INTERNATIONAL AS29606 Page 4 of 35 2.1.2.5 NCSL Publications Available from NCSL International, 2995 Wilderness Place, Suite 107, Boulder, CO 80301, Tel: 303-440-3339, www.ncsli.org.NCSL-Z540 Laboratories, Cal
24、ibration, and Measuring and Test Equipment. (DoD adopted) 2.1.2.6 IPC Publications Available from IPC 3000 Lakeside Drive, Suite 309S, Bannockburn, Illinois 60015-1249, Tel 847-615-7100, www.ipc.orgIPC/JEDEC J-STD-002 Solderability Tests for Component Leads, Terminations, Lugs, Terminals and Wires 2
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS296062014WIREELECTRICALSTRANDEDUNINSULATEDCOPPERCOPPERALLOYORALUMINUMORTHERMOCOUPLEEXTENSIONGENERALSPECIFICATIONFOR

链接地址:http://www.mydoc123.com/p-1023960.html