SAE ARP 6400-2010 Recommended Practice for Processing and Handling Wire and Cable with Silver Plated Conductors and Shields《加工和处理带有镀银导体和屏蔽的线和电缆的推荐实施规程》.pdf
《SAE ARP 6400-2010 Recommended Practice for Processing and Handling Wire and Cable with Silver Plated Conductors and Shields《加工和处理带有镀银导体和屏蔽的线和电缆的推荐实施规程》.pdf》由会员分享,可在线阅读,更多相关《SAE ARP 6400-2010 Recommended Practice for Processing and Handling Wire and Cable with Silver Plated Conductors and Shields《加工和处理带有镀银导体和屏蔽的线和电缆的推荐实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions.Copyright 2016 SAE InternationalAll rights reserved. No part of this publi
3、cation may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE.TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada)Tel: +1 724-776-4970 (out
4、side USA)Fax: 724-776-0790Email: CustomerServicesae.orgSAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedbackon this Technical Report, please visithttp:/www.sae.org/technical/standards/ARP6400AEROSPACERECOMMENDED PRACTICEARP6400Issued 2010-10Reaffirmed 2016-05Recommended Practi
5、ce for Processing and Handling Wire and Cablewith Silver Plated Conductors and ShieldsRATIONALEARP6400 has been reaffirmed to comply with the SAE five-year review policy.1. SCOPE This ARP specifies the recommended methods of handling silver coated conductors and shield, by the conductor fabricator,
6、wireinsulator, distributors, harness or assembly houses, and OEMs. Red Plague mitigation depends upon each link in the chain of supply handling the wire and cable properly. 2. REFERENCES The following publications form a part of this document to the extent specified herein. The latest issue of SAE p
7、ublications shall apply. The applicable issue of the other publications shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and references cited herein, the text of this document takes precedence. Nothing in this document, howeve
8、r, supersedes applicable laws and regulations unless a specific exemption has been obtained. The following document provides further information which the user may find helpful in understanding cupous/cupric oxide corrosion of silver coated conductors and shields. 2.1 SAE Publications Available from
9、 SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org. AIR4487A Investigation of Silver Plated Conductor Corrision (Red Plague) 3. APPLICABLE DOCUMENTS 3.1 ASTM Publications Available from ASTM Inte
10、rnational, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, Tel: 610-832-9585, www.astm.org. ASTM D-5486 Standard Specification for Pressure-Sensitive Tape for Packaging, Box Closure, and Sealing 3.2 U.S. Government Publications Available from the Document Automation and Produ
11、ction Service (DAPS), Building 4/D, 700 Robbins Avenue, Philadelphia, PA 19111-5094, Tel: 215-697-6257, http:/assist.daps.dla.mil/quicksearch/. MIL-D-3464 Desiccants, Activated, Bagged, Packaging Use and Static Dehumidification MIL-DTL-29606 Wire, Electrical, Stranded, Uninsulated Copper, Copper All
12、oy, or Aluminum, or Thermocouple Extension, General Specification for. MIL-P-23242B Plastic Coating Compound, Strippable, for Electroplating MS20003 Indicator, Humidity, Card, Three Spot, Impregnated Areas (Cobaltous Chloride) 4. GENERAL DESIGN REQUIREMENTSSilver coated wire and shields shall meet t
13、he requirements of MIL-DTL-29606. 5. PROCEDURES5.1 General Environmental Conditions 5.1.1 Temperature and humidity conditions warrant attention. When humidity is high, a small temperature difference can cause condensation on conductor and insulation surfaces. Caution is therefore warranted when movi
14、ng silver coated copper material to or through areas lacking adequate environmental controls. Bagging the material is useful for protecting against condensation while the wire or cables temperature stabilizes. 5.1.2 Storage duration: Storage of wire or cable for longer than one (1) year should be mi
15、nimized if at all possible, and good commercial practices of first in first out inventory management should be practiced. Material stored for longer than one (1) year should be examined for evidence of corrosion and if it is still acceptable, be repackaged with a new desiccant. 5.1.3 Storage Areas:
16、Should be a dry area, and away from any possible exposure to water. Humidity controlled rooms with less than 50% humidity are recommended for long term storage where practical. If the storage area is not temperature/humidity controlled, then material should be stored in bags with dessicants. Bagging
17、 material, if used for packaging, should be polyethylene. Storage conditions for the desiccant (MIL-D-3464), Type II and determination of its use quantity per package should be in accordance with the desiccant manufacturers instructions. Humidity indicator cards per MS20003-2 should also be placed i
18、n the bag and monitored to determine if the desiccant should be replaced. 5.1.4 Material movement: On-site material movement out of or into an air conditioned location, and off site transportation through variable environments, can cause moisture condensation. Therefore temperature and humidity cond
19、itions need be considered in preparation for these material movements. Sealed bags are useful for protecting against this condensation while the wire is allowed to temperature stabalizes at the new location. Note: Some common packaging materials, such as paper wrapping, rubber bands, and cardboard b
20、oxes may contain and offgas small ammounts of sulfur which can attach the silver plating. 5.2 Conductor and Shield Manufacturers 5.2.1 Plating: The coating of the copper or copper alloy conductors is critical to the long term quality of the material. The plating thickness need be sufficiently thick,
21、 non-porous, and unpitted to avoid exposure of the underlying copper. Therefore platers need ensure that the coating is applied with best commercial practices. 5.2.2 Drawing: Silver coating damage may occur during the drawing process. The conductor manufacturer needs to have good quality controls to
22、 verify that this process in no way damages the plating. A die inspection plan should be implemented to ensure that dies are replaced if damaged which can cause reductions in silver coating thickness or exposed copper. SAE INTERNATIONAL ARP64002 OF 45.2.3 Stranding: Assembly of the individual strand
23、s need to be performed with great care, particullarly along the outer edge of the strands which come in direct contact with the closing machinery. Contact points in the conductor path as well as the closing die needs to be inspected under magnification as part of an inspection plan inorder to verify
24、 that it is smooth and free of any damage. Upon completion of the process the conductors should be inspected to verify that the plating has not been reduced below minimum requirements and that no exposure of copper has occurred. Inspection results should be tracked using statistical process control
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEARP64002010RECOMMENDEDPRACTICEFORPROCESSINGANDHANDLINGWIREANDCABLEWITHSILVERPLATEDCONDUCTORSANDSHIELDS

链接地址:http://www.mydoc123.com/p-1023266.html