1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2013 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/AIR4092A AEROSPACE INFORMATION REPORT AIR4092 REV. A Issued 1988-04 Revised 1996-
5、10 Reaffirmed 2013-01 Superseding AIR4092 Investigation of PTFE “Melt“ Phenomenon for High Pressure Hoses RATIONALE AIR4092A has been reaffirmed to comply with the SAE five-year review policy. TABLE OF CONTENTS1. SCOPE .22. APPLICABLE DOCUMENTS23 ABSTRACT.24. HISTORY35. TEST PROCEDURE.46. PURPOSE 47
6、. TEST EQUIPMENT 48. TEST RESULTS .49. CONCLUSIONS .510. RECOMMENDATION.5FIGURE 1 THROUGH 3 - HOSE ASSEMBLY SPECIMENSFIGURE 4 - TEST SETUPFIGURE 5 AND 6 - BARE 230 L.W. HOSE FAILUREFIGURE 7 AND 8 - 230 WITH INTEGRAL FIRESLEEVE, L.W. HOSE FAILUREFIGURE 9 AND 10 - 660 H.P. TESTED - NO FAILURESAE AIR40
7、92A Page 2 of 14 1. SCOPE:To provide information regarding a unique failure mode and alternate solutions for consideration by application designers.2. APPLICABLE DOCUMENTS:The following publications form a part of this document to the extent specified herein. The latest issue of SAE publications sha
8、ll apply. The applicable issue of other publications shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes appli
9、cable laws and regulations unless a specific exemption has been obtained.2.1 SAE Publications:Available from SAE, 400 Commonwealth Drive, Warrendale, PA 15096-0001.AS115AS604AS621AS13392.2 U.S. Government Publications:Available from DODSSP, Subscription Services Desk, Building 4D, 700 Robbins Avenue
10、, Philadelphia, PA 19111-5094.MIL-H-383603. ABSTRACT:The lightweight, high pressure hose with high density braid is susceptible to PTFE innercore melt from induced and applied axial vibration starting at double amplitudes of about 0.180 and frequency of 20 Hz. The use of an integral silicone firesle
11、eve helps to “dampen“ out these vibrations, and it increases the threshold for damage to about 0.300 double amplitude. The use of heavy duty, spiral wrapped, high pressure hose, as a practical thing, eliminates the PTFE “melt“ phenomenon. This heavy duty hose does have an axial displacement damage t
12、hreshold of about 0.750 double amplitude, but the mode of failure is mechanical wire breakage not PTFE “melt“. There were no failures of the spiral wrapped hose below 0.750 double displacement.The problem is international, and there have been failures on commercial and military aircraft using AS1339
13、 (AS115.etc.) assemblies with bare hose and hose with integral firesleeve. There are no failure reports for AS604 hose (AS621.etc.) assemblies.There have been no additional failure reports since 1984, primarily due to SAE G-3 activity to alert the aerospace community.SAE AIR4092A Page 3 of 14 4. HIS
14、TORY:Starting in 1978, Titeflex began receiving reports from the field that in certain main pump and auxiliary pump applications, the PTFE, high pressure product lines with high density, lightweight braid construction were failing after as little as 7 h of service due to melting of the PTFE liner wh
15、ich, among other symptoms, showed PTFE extrusion (“porcupining“) through the braid.From 1978 - 1983, multiple failures were reported and confirmed for hoses on pumps in hose sizes -6, -8, and -10.These included confirmed reports from:DeHavillandCanadairBoeing VertolSNIAS (Air Bus)Other unconfirmed r
16、eports of similar failures were received from:U.S. Air ForceS.A.S.McDonnell/DouglasFailures reported involved hoses made by all of the suppliers of the high density braid, lightweight, high pressure hose. In some cases, where Titeflex high density, braided hoses failed, Titeflex had been using heavy
17、 duty spiral-wrapped hose for many years without difficulty. The substitution to high density/lightweight hose was made to save weight. Immediately after the substitution was made, the failures began. When the heavy duty, spiral-wrapped hose was reinstalled, the problem disappeared. In all cases whe
18、re the problem has occurred, Titeflex has recommended the installation of the heavy duty spiral-wrapped hose. There has never been a “melt Teflon“ failure using the heavy duty hose.The second manufacturer of this lightweight construction experienced the “melt PTFE“ failures in frequencies and severi
19、ty equivalent to the Titeflex experience. Reports from that source indicated that the application of a heavy integral, elastomeric sleeve provided sufficient “dampening“ to prevent the problem from occurring.In the period since January 1983 - January 1984, there have been no further confirmed failur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAIR4092A1996INVESTIGATIONOFPTFEMELTPHENOMENONFORHIGHPRESSUREHOSES 高压 软管 聚四氟乙烯 调查 PDF

链接地址:http://www.mydoc123.com/p-1020130.html