1、*USACE / NAVFAC / AFCESA / NASA UFGS-26 05 13.00 40 (November 2013)-Preparing Activity: NASA SupersedingUFGS-26 05 13.00 40 (August 2010)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 2013*SECTION TABLE OF CONTENTSDIVISION 26 - ELECTRICALSECTION 26 05 13.0
2、0 40MEDIUM-VOLTAGE CABLES11/13PART 1 GENERAL1.1 REFERENCES1.2 DEFINITIONS1.3 SUBMITTALS1.4 PREDICTIVE TESTING AND INSPECTION TECHNOLOGY REQUIREMENTS1.5 MAINTENANCE MATERIALS SUBMITTALS1.6 QUALITY ASSURANCE1.7 DELIVERY, STORAGE AND HANDLINGPART 2 PRODUCTS2.1 SYSTEM DESCRIPTION2.1.1 Cable Voltage Rati
3、ngs2.2 EQUIPMENT2.2.1 Multiple-Conductor Shielded Cables2.2.1.1 Varnished Cambric and Lead2.2.1.2 Varnished Cambric with Interlocked Armor2.2.1.3 Natural Synthetic Rubber with Interlocked Armor2.2.1.4 Butyl Rubber with Neoprene Jacket2.2.1.5 Cross-Linked Polyethylene with PVC Jacket2.2.1.6 Ethylene
4、Propylene Rubber (EPR) with Jacketed Interlocked Armor2.2.2 Multiple-Conductor, Nonshielded Cables2.2.2.1 Natural Synthetic Rubber with Neoprene Jacket2.2.2.2 Butyl Rubber with Neoprene Jacket2.2.2.3 Cross-Linked Polyethylene with PVC Jacket2.2.2.4 Ethylene-Propylene with PVC Jacket2.2.3 Single-Cond
5、uctor Shielded Cables2.2.3.1 Butyl Rubber with Neoprene Jacket2.2.3.2 Cross-Linked Polyethylene with PVC Jacket2.2.3.3 Cross-Linked Polyethylene with Interlocked Armor2.2.3.4 Ethylene-Propylene-Rubber-Insulated with PVC Jacket2.2.4 Single-Conductor Nonshielded Cables2.2.4.1 Butyl Rubber with Neopren
6、e Jacket2.2.4.2 Cross-Linked PolyethyleneSECTION 26 05 13.00 40 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.2.4.3 Ethylene-Propylene-Rubber-Insulated with PVC Jacket2.2.5 Portable Cables2.2.6 Cable Supports And Fittings2.3 COMPONENTS2.3.1
7、 Conductors2.3.2 Cable Identification2.3.3 Nonmetallic Jacket2.3.3.1 Interlock Armored Cable2.3.3.2 Lead-Sheathed Cable2.3.3.3 Terminations2.4 TESTS, INSPECTIONS, AND VERIFICATIONS2.4.1 FlammabilityPART 3 EXECUTION3.1 INSTALLATION3.1.1 Moisture-Testing Before Pulling3.1.2 Protection During Splicing
8、Operations3.1.3 Duct Cleaning3.1.4 Pulling Cables in Ducts, Manholes and Utility Tunnels3.1.5 Splices and Terminations3.1.6 Multiple-Conductor Potheads3.1.7 Single-Conductor Potheads3.2 FIELD QUALITY CONTROL- End of Section Table of Contents -SECTION 26 05 13.00 40 Page 2Provided by IHSNot for Resal
9、eNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-26 05 13.00 40 (November 2013)-Preparing Activity: NASA SupersedingUFGS-26 05 13.00 40 (August 2010)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 20
10、13*SECTION 26 05 13.00 40MEDIUM-VOLTAGE CABLES11/13*NOTE: This guide specification covers the requirements for medium voltage cables, including shielded and nonshielded single-and multiple-conductor power cables, portable cables, cable splices and terminations, single- and multiple-conductor pothead
11、s, and fireproofing cables in manholes and utility tunnels.Show plan layout of power cable and power-cable terminations on drawings. Show size, type, electrical characteristics, and raceway system of power cables and type of cable termination on electrical riser diagrams.Adhere to UFC 1-300-02 Unifi
12、ed Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or i
13、nsert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL*
14、NOTE: If Section 26 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS is not included in the project specification, insert applicable requirements therefrom and delete the following paragraph.*SECTION 26 05 13.00 40 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without
15、license from IHS-,-,-Section 26 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS applies to work specified in this section.1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic design
16、ation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Ref
17、erence feature to update the issue dates.References not used in the text are automatically deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent refere
18、nced. The publications are referred to within the text by the basic designation only.ASSOCIATION OF EDISON ILLUMINATING COMPANIES (AEIC)AEIC C8 (2000) Extruded Dielectric Shielded Power Cables Rated 5 Through 46 kVAEIC CS1 (2012) Impregnated-Paper-Insulated, Metallic Sheathed Cable, Solid TypeASTM I
19、NTERNATIONAL (ASTM)ASTM B3 (2012) Standard Specification for Soft or Annealed Copper WireASTM D746 (2013) Standard Test Method for Brittleness Temperature of Plastics and Elastomers by ImpactINSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE)IEEE 383 (2003; R 2008) Standard for Qualifying Class
20、 1E Electric Cables and, Field Splices for Nuclear Power Generating Stations 2004IEEE 400.2 (2013) Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)SECTION 26 05 13.00 40 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license f
21、rom IHS-,-,-NATIONAL AERONAUTICS AND SPACE ADMINISTRATION (NASA)RCBEA GUIDE (2004) NASA Reliability Centered Building and Equipment Acceptance GuideNATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)ANSI/NEMA WC 71/ICEA S-96-659 (1999) Standard for Nonshielded Cables Rated 2001-5000 Volts for use i
22、n the Distribution of Electric EnergyNEMA WC 2 (1980; Rev 1 1989; R 1998; R 2005) Standard for Steel Armor and Associated Coverings for Impregnated Paper Insulated Cables (ICEA S-67-401 5th Edition)NEMA WC 27500 (2012) Standard for Aerospace and Industrial Electrical CableNEMA WC 70 (2009) Power Cab
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGUFGS26051300402013MEDIUMVOLTAGECABLESPDF

链接地址:http://www.mydoc123.com/p-1019652.html