REG UFGS-23 82 16 00 40-2013 AIR COILS.pdf
《REG UFGS-23 82 16 00 40-2013 AIR COILS.pdf》由会员分享,可在线阅读,更多相关《REG UFGS-23 82 16 00 40-2013 AIR COILS.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-23 82 16.00 40 (May 2013)-Preparing Activity: NASA SupersedingUFGS-23 82 16 (February 2011)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2013*SECTION TABLE OF CONTENTSDIVISION 23 - HEATING, VENTILATING, AND AIR CONDITION
2、INGSECTION 23 82 16.00 40AIR COILS05/13PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 QUALITY ASSURANCEPART 2 PRODUCTS2.1 COMPONENTS2.1.1 Coil Pressure and Temperature Ratings2.1.2 Coil Casings2.1.3 Coil Headers2.1.4 Coil Tubing2.1.5 Coil Circuiting2.1.6 Drainable Coils2.2 COIL TYPES2.2.1 Steam Heati
3、ng2.2.2 Hot-Water Heating2.2.3 Chilled-Water Cooling2.2.4 Volatile Refrigerant CoolingPART 3 EXECUTION3.1 INSTALLATION3.2 TESTS3.3 OPERATION AND MAINTENANCE- End of Section Table of Contents -SECTION 23 82 16.00 40 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without li
4、cense from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-23 82 16.00 40 (May 2013)-Preparing Activity: NASA SupersedingUFGS-23 82 16 (February 2011)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2013*SECTION 23 82 16.00 40AIR COILS05/13*NOTE: This guide speci
5、fication covers the requirements for coils for cold water, hot water, steam, and refrigerant.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for
6、project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended cha
7、nges for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*PART 1 GENERALSection 23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS applies to work specified in this section.1.1 REFERENCES*NOTE: This paragraph is used to list the public
8、ations cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Referenc
9、e Article to automatically place the reference in the Reference Article. Also use the SECTION 23 82 16.00 40 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Reference Wizards Check Reference feature to update the issue dates.References not used
10、 in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text b
11、y the basic designation only.AIR-CONDITIONING, HEATING AND REFRIGERATION INSTITUTE (AHRI)AHRI 410 (2001; Addendum 1 2002; Addendum 2 2005; Addendum 3 2011) Forced-Circulation Air-Cooling and Air-Heating CoilsASTM INTERNATIONAL (ASTM)ASTM A653/A653M (2011) Standard Specification for Steel Sheet, Zinc
12、-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process1.2 SUBMITTALS*NOTE: Review Submittal Description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project.The Guide Specification
13、technical editors have designated those items that require Government approval, due to their complexity or criticality, with a “G.“ Generally, other submittal items can be reviewed by the Contractors Quality Control System. Only add a “G” to an item, if the submittal is sufficiently important or com
14、plex in context of the project.For submittals requiring Government approval on Army projects, use a code of up to three characters within the submittal tags following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“
15、 for Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first b
16、racketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects.SECTION 23 82 16.00 40 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*Government approval is required for submittals with a “G“ designa
17、tion; submittals not having a “G“ designation are for Contractor Quality Control approval.for information only. When used, a designation following the “G“ designation identifies the office that reviews the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITT
18、AL PROCEDURES:SD-01 Preconstruction SubmittalsRecord of Existing Conditions; G; G, _SD-02 Shop DrawingsFabrication Drawings; G; G, _Connection Diagrams; G; G, _Layout of All Controls; G; G, _Internal Tubing and Wiring; G; G, _ Installation Drawings; G; G, _Record Drawings; G; G, _SD-03 Product DataS
19、team Heating; G; G, _Hot-Water Heating; G; G, _Chilled-Water Cooling; G; G, _Volatile Refrigerant Cooling; G; G, _SD-05 Design DataDesign Analysis and Calculations; G; G, _SD-06 Test ReportsFinal Test Reports; G; G, _SD-07 CertificatesCertificates of Conformance; G; G, _SD-10 Operation and Maintenan
20、ce DataOperation and Maintenance Manuals; G; G, _1.3 QUALITY ASSURANCESubmit a record of existing conditions consisting of the results of a survey of work area conditions and features of existing structures and facilities within and adjacent to the jobsite.SECTION 23 82 16.00 40 Page 4Provided by IH
21、SNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Provide coils that bear the ARI certification seal indicating compliance with AHRI 410. Submit Certificates of Conformance for following items showing conformance with AHRI 410:a. Coilb. Coil casingsc. Coil headersd.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGUFGS23821600402013AIRCOILSPDF