REG NASA-LLIS-6144-2012 Lessons Learned - Shuttle External Tank Engine Cut Off Feed Through Connector Failure.pdf
《REG NASA-LLIS-6144-2012 Lessons Learned - Shuttle External Tank Engine Cut Off Feed Through Connector Failure.pdf》由会员分享,可在线阅读,更多相关《REG NASA-LLIS-6144-2012 Lessons Learned - Shuttle External Tank Engine Cut Off Feed Through Connector Failure.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Public Lessons Learned Entry: 6144 Lesson Info: Lesson Number: 6144 Lesson Date: 2010-11-1 Submitting Organization: MSFC Submitted by: Kristen Kinder Subject: Shuttle External Tank Engine Cut Off Feed Through Connector Failure Abstract: After much investigation (and launch scrubs), a problem was iso
2、lated to the feed through connector in the bottom of a hydrogen tank. Electrical connector integrity can be significantly impacted at cryogenic temperatures. Description of Driving Event: STS-114 external tank and subs were plagued with the loss of the wet/dry indication of the low level cut off sen
3、sors. This caused many launches to be scrubbed. Thinking the problem was with the sensors themselves, great effort was spent on improving them (e.g. swage connections, x-rays, etc.), but the problem kept recurring. Finally, after much investigation (and launch scrubs), the problem was isolated to th
4、e feed through connector in the bottom of the hydrogen tank. A design change to the connector changed the orientation and surface area involved between the mating sides. When the tank was filled, moist atmospheric air was drawn into the connector. The water in the air would freeze and as the connect
5、or chilled down and contracted, the electrical connection on one or more of the pins would be lost. After the tank was drained and it heated back up, the connection would be reestablished. After the problem was isolated to the feed thru connector, the Centaur Program told of how they had the same pr
6、oblem with their connector and how they fixed it by soldering the external connection, rather than relying on the mechanical connection alone. Lesson(s) Learned: Electrical connector integrity can be significantly impacted at cryogenic temperatures. The mechanical design of electrical connectors can
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGNASALLIS61442012LESSONSLEARNEDSHUTTLEEXTERNALTANKENGINECUTOFFFEEDTHROUGHCONNECTORFAILUREPDF

链接地址:http://www.mydoc123.com/p-1019519.html