1、Lessons Learned Entry: 2056Lesson Info:a71 Lesson Number: 2056a71 Submitting Organization: KSCa71 Submitted by: Michael Bella71 POC Name: Dave Facemirea71 POC Email: david.l.facemirenasa.gova71 POC Phone: 321-867-7232Subject: Building M6-794 Roofing Type A Mishap Abstract: On March 17, 2006, a const
2、ruction worker fell from the roof of Supply Warehouse #1 (Building M6-794) at the Kennedy Space Center. Rescue personnel arrived at the mishap scene minutes later, and the worker was subsequently airlifted to the hospital but passed away later that day due to fatal head injuries. At the time of the
3、mishap, the workers were installing a corrugated metal roofing panel as part of Subcontract X04524-6 and the employee was working close to the edge of a roof without proper full protection. Because of this fatality, many recommendations were made to prevent a mishap such as this from occurring again
4、. These recommendations include: requiring physical restraints when working close to edge of a roof, reserving non-physical restraint systems for special circumstances requiring approval through formal variance.Description of Driving Event: On March 17, 2006, a crew of three (two workers and a super
5、intendent) construction workers began to work on the roof of Building M6-794. Before working on the roof, however, the crew needed to wait on an aerial lift that was transporting materials to the roof for panel installations. The three construction workers began replacing the panels on the roof afte
6、r the aerial lift delivered the supplies necessary. They started at the northwest corner of the building to replace roofing at that location and then moved to the southeast corner. As the employees continued to work on the roof, only the Safety Monitoring System was used as fall protection. The Safe
7、ty Monitoring System alone would have been an acceptable form of protection if the width of the roof of Building M6-794 was Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-less than 50 feet; however, this roof had a width of more than 50 feet which c
8、onflicted with OSHA standards. According to OSHA 29 CFR 1926.502(h)(1)(ii), safety monitors are intended to warn the employee when it appears that the employee is unaware of a fall hazard or is acting in an unsafe manner. According to OSHA 29 CFR 1926.501(b)(10), safety monitoring alone is allowed w
9、ithout a Warning Line System on roofs less than 50 ft wide. After the installation of a second panel, the crew took a break for lunch at which point the two employees left the site while the superintendent remained. Upon their return from the break, they resumed work and began installing the last ro
10、ofing panel. While working on the third panel, the superintendent violated the requirements set by OSHA 29 CFR 1926.502(h)(1)(v) as he acted as the superintendent, safety monitor, as well as one who helped replace the third roofing panel. It was while the crew was working on the final when the emplo
11、yee lost his footing, released the panel that was held in his hands, and fell from the roof of the building. He fell approximately 10 feet, struck an air-conditioning unit with his head, and feel and another 7 feet to the loading dock. The worker passed due to severe head injury later that day.Lesso
12、n(s) Learned: The employee was working too close to the edge of a roof (17 Feet above the ground) without proper fall protection. When roofing jobs are preformed, subcontractors are responsible for judging if the standards of 29 CFR 1926.501 (low-sloped roof) and 29 CFR 19.26750 (steel erection) alo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGNASALLIS20562009LESSONSLEARNEDBUILDINGM6794ROOFINGTYPEAMISHAPPDF

链接地址:http://www.mydoc123.com/p-1019356.html