1、Best Practices Entry: Best Practice Info:a71 Committee Approval Date: 2000-04-14a71 Center Point of Contact: JPLa71 Submitted by: Wilson HarkinsSubject: Part Electrical Stress Analysis Practice: Every part in an electrical design is subjected to a worst-case part stress analysis performed at the ant
2、icipated part temperature experienced during the assembly qualification test (typically 75 degrees C). Every part must meet the project stress derating requirements or be accepted by a formal project waiver.Abstract: Preferred Practice for Design therefore, a conservative temperature assumption is m
3、ade. Highly stressed parts are identified for possible replacement with more robust parts or for possible circuit changes. The final design is confirmed by analysis, with part temperatures based on a part level thermal analysis, and with voltages and currents derived from either specification limits
4、 or the results of worst-case circuit analysis.Numerous life tests have been performed on electrical parts that establish the relationship of part life to applied stresses. There is a very strong dependence. The life expectancy typically can be doubled or tripled by operating at half the manufacture
5、rs full rated (100 percent) stresses, which typically are commensurate with a 10,000-hour life expectancy. Complex, multiple year missions must achieve very low part failure rates to achieve mission goals; therefore, operation at derated conditions is mandatory. Although typical reliability predicti
6、ons are based on nominal stresses, circuit nonlinearities and part and voltage variations can cause large operating point variations. Therefore, it is essential that the conservative approach of using worst-case stresses be implemented as standard practice.Although average temperatures during a miss
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGNASALLIS07822000LESSONSLEARNEDPARTELECTRICALSTRESSANALYSISPDF

链接地址:http://www.mydoc123.com/p-1018428.html