1、Lessons Learned Entry: 0442Lesson Info:a71 Lesson Number: 0442a71 Lesson Date: 1992-11-13a71 Submitting Organization: LERCa71 Submitted by: G. MichalsonSubject: Pre-Run Checklists Description of Driving Event: A roof fire occurred in Cell 23 of Building 35. An Accident Review Team concluded that the
2、 cause of the fire was the inoperability of the water quench system used to cool the hot combustion gases exiting the test section. The problem was that the ACROMAG Transmitter was not plugged in and had remained closed. It did not regulate the appropriate amount of quench water for a given hot exha
3、ust temperature.The quench water system had facility alarm and shutdown meters which monitored exhaust gas temperatures downstream of the quench spray station. The high limits for these meters were set too high (800 and 860 degrees F, respectively) and should have been set at 650 degrees F. These me