PPI TN-42-2013 Recommended Minimum Training Guidelines for PE Pipe Butt Fusion Joining Operators for Municipal and Industrial Projects.pdf
《PPI TN-42-2013 Recommended Minimum Training Guidelines for PE Pipe Butt Fusion Joining Operators for Municipal and Industrial Projects.pdf》由会员分享,可在线阅读,更多相关《PPI TN-42-2013 Recommended Minimum Training Guidelines for PE Pipe Butt Fusion Joining Operators for Municipal and Industrial Projects.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、 105 Decker Court, Suite 825, Irving, TX 75062 P: 469-499-1044 F: 469-499-1063 www.plasticpipe.org Recommended Minimum Training Guidelines for PE Pipe Butt Fusion Joining Operators for Municipal and Industrial Projects TN-42 / March 2013 2 Foreword This technical note was developed and published wit
2、h the technical help and financial support of the members of the PPI (Plastics Pipe Institute, Inc). The members have shown their interest in quality products by assisting independent standards-making and user organizations in the development of standards, and also by developing reports on an indust
3、ry-wide basis to help engineers, code officials, specifying groups, and users. This technical note has been prepared by PPI as a service to the industry. The information in this note is offered in good faith and believed to be accurate at the time of its preparation, but is offered “as is” without a
4、ny express or implied warranty including WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Any reference to or testing of a particular proprietary product should not be construed as an endorsement by PPI, which does not endorse the proprietary products or processes of any manufactu
5、rer. The information in this report is offered for consideration by industry members in fulfilling their own compliance responsibilities. PPI assumes no responsibility for compliance with applicable laws and regulations. PPI intends to revise this note from time to time, in response to comments and
6、suggestions from users of this note. Please send suggestions of improvements to the address below. Information on other publications can be obtained by contacting PPI directly or visiting the web site. The Plastics Pipe Institute, Inc. www.plasticpipe.org March 2013 105 Decker Court, Suite 825, Irvi
7、ng, TX 75062 P: 469-499-1044 F: 469-499-1063 www.plasticpipe.org 3 PURPOSE The purpose of this document is to provide a general outline of PPIs recommended minimum guidelines for training an operator in properly and safely making good quality butt- fusion joints in PE pipe systems. This training gui
8、de is intended to recommend a consistent minimum level of fusion operator proficiency; certain installations may require additional operator training and proficiency. SCOPE Butt fusion joining of PE pipe is a relatively simple, forgiving, and dependable process. However, as with any kind of pipe ins
9、tallation, proper procedures and diligence must always be used to consistently make satisfactory joints. Fusion machine operators should demonstrate an aptitude for using mechanical equipment and be generally familiar with laying pipe. They should have a demonstrated ability to follow procedures and
10、 be conscientious in their work. The amount of time it takes to provide the specified training can vary greatly and depends on the number of individuals being trained as well as their aptitude and willingness to follow directions. However, participants shall not be considered “trained” until they ha
11、ve demonstrated proficiency on at least two test joints made under circumstances and field conditions representative or similar to those of the project. PE Pipe Sizes and SDR/DR PE pipe for use in industrial and municipal applications is produced in accordance with applicable industry standards (AST
12、M, AWWA, API). In AWWA, the pipe outside diameters (ODs) conform to the OD dimensions of iron pipe IPS, or to equivalent OD for DI pipe (DIOD). In general, pipes are manufactured and measured based on OD (outside diameter) and wall thickness. The ratio of outside diameter to minimum wall thickness d
13、efines the pipes SDR (Standard Dimension Ratio) or DR (Dimension Ratio) number. These numbers also define the pipes pressure rating at 80oF (27oC) in AWWA standards. And, because of the importance of the information these numbers convey, they are required to be included in the pipe markings specifie
14、d by the applicable industry standard. These standards require that all pipes be clearly marked at specified intervals with the following information: Name or trademark of the manufacturer Production code number to identify location and date of manufacture. Nominal pipe size IPS or DIPS SDR or DR nu
15、mber, or pressure rating, or both 4 The applicable industry standard(s) with which the pipe complies e.g. ASTM, AWWA, API or a combination of those specifications to which the pipe may have been manufactured, (e.g. ASTM F714 / AWWA C-906). Use the Pipe Size and SDR/DR to determine the proper fusion
16、pressures applicable for the fusion machine and product being joined. In the event this information is not immediately available the user is advised to consult with either the fusion equipment or pipe supplier. Links to PPI and the major equipment suppliers are listed as follows: Plastics Pipe Insti
17、tute www.plasticpipe.org Connectra Fusion Equipment http:/ McElroy Manufacturing Fusion Equipment http:/ RITMO America http:/ MACHINE QUALIFICATION The selected fusion equipment shall be capable of meeting all parameters of the job. The equipment shall have jaws or reducing inserts designed to prope
18、rly hold the size of the pipes being fused, and it shall have enough hydraulic force to reach the required fusion pressure during all fusion conditions. The fusion operator shall be thoroughly familiar with and trained on the equipment being used. Such training shall include at least the following:
19、1) Safety 2) Operators manual nonetheless its impact strength is reduced as temperatures drop into these ranges. Therefore, avoid dropping pipe in sub-freezing conditions. Also, keep in mind that butt fusion, when temperatures are below -4oF (-20oC), generally requires special provisions such as por
20、table shelters or trailers or other suitable protective measures with auxiliary heating. Here are some general guidelines to address different weather conditions: Cold Temperatures, Down to 32oF ( 0oC ): When butt fusing PE pipe under these conditions, it is recommended that a temporary wind barrier
21、 be set up around the operator and fusion equipment. It is also recommended that the pipe ends be closed off by use of end caps or other means to prevent the flow of cold air. These measures will help greatly to reduce the heat loss in the heater plate and provide for a more uniform heating cycle an
22、d improved operator efficiency. Cold Ambient Temperatures Below 32oF (0o C ): In addition to the above, the following preparations should be undertaken before fusing pipes. Pipe ends should be pre-heated using a heating blanket or warm air devices to elevate the pipe temperature to improve the heat
23、cycle starting condition. With pipe mounted in the fusion machine, an alternate method of pre-heating is to position the pipe ends within to inch of the heater plate face to allow the pipe ends to warm for 30 seconds to 2 minutes, depending on the pipe size and wall thickness. Before starting pipe f
24、usion, the operator needs to ensure that the ID of the pipe is clear of moisture possibly due to frost that is being melted during the warming operations. Notice: The use of direct application open flame devices, such as torches, for heating PE pipe is prohibited due to the lack of adequate heating
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- PPITN422013RECOMMENDEDMINIMUMTRAININGGUIDELINESFORPEPIPEBUTTFUSIONJOININGOPERATORSFORMUNICIPALANDINDUSTRIALPROJECTSPDF

链接地址:http://www.mydoc123.com/p-1016792.html