PIA-TEST METHOD-6015-2015 STRENGTH AND ELONGATION TESTING SPECTRA CORD SPLICED SPECIMEN METHOD.pdf
《PIA-TEST METHOD-6015-2015 STRENGTH AND ELONGATION TESTING SPECTRA CORD SPLICED SPECIMEN METHOD.pdf》由会员分享,可在线阅读,更多相关《PIA-TEST METHOD-6015-2015 STRENGTH AND ELONGATION TESTING SPECTRA CORD SPLICED SPECIMEN METHOD.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 The following commercial specification is originally adopted from the military document. Revision A includes all known accepted revisions, amendments, notices, and Department of Defense (DoD) engineering changes previously developed for this item. Revision B and forward include changes adopted by D
2、oD and Industry to reflect technology and design evaluation. STRENGTH AND ELONGATION TESTING SPECTRA CORD; SPLICED SPECIMEN METHOD The Parachute Industry Association makes this document available for use by the Industry and Government organizations that wish to apply this specification to their prod
3、ucts. 1. SCOPE 1.1 Scope. This method is intended for determining the breaking strength and elongation of cordage that requires an eye splice to be tested. 2. TEST SPECIMEN 2.1 The test specimen shall be a single length of cordage. 2.2 The specimen shall be eye spliced at both ends with a loop big e
4、nough to go over the holding apparatus. Eye splice shall be accomplished with either a tapered buried eye splice, as per FED-STD-191 TM 6015, or a blunt end cut at a 45 degree angle. The taper shall consist of cutting out every fifth pick in right and left strands for 16, 24 and 32 strand round brai
5、ds and alternately fourth and fifth picks for 20 strand braid. For some types of cord a bartack may be used to secure the finger trap, but is not always necessary. 2.3 The specimen shall have a minimum of 6 inches of free cord (see FIGURE 2) between the ends of the finger traps. 3. NUMBER OF DETERMI
6、NATIONS 3.1 Number of determinations. Unless otherwise specified in the procurement document, five specimens shall be tested for every sample unit required per sampling method identified in PIA-C-7515. 4. APPARATUS 4.1 Apparatus. The apparatus for determining the breaking strength and elongation sha
7、ll conform to requirements identified in Section 4 of FED-STD-191 TM 6015 with the following exception; the straining mechanism shall be such, that during the test, the movement of the pulling clamp shall be at a uniform rate of 2-1/2 1/2 inches per minute. 4.2 An ink marker with a very fine tip sho
8、uld be used to mark the specimen. PIA-TEST METHOD-6015 22 January 2015 DISTRIBUTION STATEMENT: All Rights Reserved. No Part of this publication may be reproduced without prior written permission from Parachute Industry Association. Additional copies may be purchased on-line from PIA Specifications a
9、nd Products at: . Copyright Protected: Do Not Copy!PIA-TEST METHOD-6015 4.3 A pair of dividers or other suitable measuring device should be used to calculate the distance between marks on the specimen; the device should be graduated in divisions of 1/16 of an inch. 5. PROCEDURE 5.1 The specimen shal
10、l be placed within the holding devices with the long dimension parallel to the application of the load (see FIGURE 3). If elongation measurements are required, a tension of 1 percent of the minimum breaking strength shall be applied while under this tension. Two fine gage marks shall be spaced a min
11、imum of 5 inches apart on the specimen in such a manner that neither mark will be closer than 1/2 inch to the end of the finger trap. If the resultant marks are not exactly 5 inches apart, the precise measurements shall be recorded to 1/16 of an inch. This original distance is identified as “0” in t
12、he calculation. No marks shall be on the eye splice itself. 5.2 Elongation. If elongation is required, elongation shall be determined on the same specimen being tested for breaking strength. The machine shall be stopped and the distance between marks shall be measured and recorded at 75 percent of t
13、he minimum breaking strength. The use of an optical extensometer is allowed as long as all other requirements of this test method are met. This is the final distance identified as E in the calculation. The distance between the marks shall be measured to the nearest 1/16 of an inch. 5.3 Breaking stre
14、ngth. To measure breaking strength, the load is applied until the sample ruptures and the maximum break strength shall be read from the dial, scale or chart and recorded. 5.4 The test result shall only be considered valid and reportable if the break occurs in the free cord at or between the ends of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- PIATESTMETHOD60152015STRENGTHANDELONGATIONTESTINGSPECTRACORDSPLICEDSPECIMENMETHODPDF

链接地址:http://www.mydoc123.com/p-1016719.html