1、 The following commercial specification is an original Parachute Industry Association specification. _ PERCENT SOLIDS ADD-ON FOR CORD, NYLON, CLASS F, DETERMINATION OF The Parachute Industry Association makes this document available for use by Industry and Government organizations that wish to apply
2、 this specification to their products. 1. SCOPE 1.1 Scope. This method is intended to determine the percent solid fluorocarbon add-on to Cord, Nylon and Cord, Nylon, Coreless when treated with fluorocarbon. 2. TEST SPECIMEN 2.1 Test Specimen. Two (2) specimens shall be a single length of approximate
3、ly 4 yards (144 inches) each. 3. NUMBER OF DETERMINATIONS 3.1 Number of Determinations. Unless otherwise specified in the procurement document two determinations shall be made from each sample unit. 4. APPARATUS 4.1 Tape or ruler. Tape or ruler graduated in increments of 1/16” capable of measuring n
4、ine (9) feet (108”). 4.2 Weight. 3 oz. weight with the capability of being suspended from end of cord sample. 4.3 Oven. Hot air circulating oven capable of maintaining required temperature within 4F (2C). 4.4 Scale. Scale with accuracy to one-thousandth (.001) of a gram. 4.5 Marking medium. Water-in
5、soluble ink marker. PIA-TEST METHOD-3000A 25 November 2013 Superseding PIA-TEST METHOD-3000 15 January 2009 DISTRIBUTION STATEMENT: All Rights Reserved. No Part of this publication may be reproduced without prior written permission from Parachute Industry Association. Additional copies may be purcha
6、sed on-line from PIA Specifications and Products at: . Copyright Protected: Do Not Copy!PIA-TEST METHOD-3000A 5. PROCEDURE 5.1 Samples of each lot of cord shall be selected during the fluorocarbon process. 5.2 From the same continuous end, cut two (2) four (4) yard (approximate) samples from the unt
7、reated cord. Identify the samples as untreated. From where the samples were cut, knot the two (2) ends back together and send through the coating process. 5.3 After the same continuous end comes out of the process, coated and cured, cut two (2), four (4) yard samples (approximately) of the treated c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- PIATESTMETHOD3000A2013PERCENTSOLIDSADDONFORCORDNYLONCLASSFDETERMINATIONOFPDF

链接地址:http://www.mydoc123.com/p-1016711.html