NFPA 1971 AMD 2-2013 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting (Effective Date 3 27 2013).pdf
《NFPA 1971 AMD 2-2013 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting (Effective Date 3 27 2013).pdf》由会员分享,可在线阅读,更多相关《NFPA 1971 AMD 2-2013 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting (Effective Date 3 27 2013).pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 Tentative Interim Amendment NFPA1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting 2013 Edition Reference: Various TIA 13-2 (SC 13-3-18/TIA Log #1092) Pursuant to Section 5 of the NFPA Regulations Governing the Development of NFPA Standards, the National
2、Fire Protection Association has issued the following Tentative Interim Amendment to NFPA 1971, Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting, 2013 edition. The TIA was processed by the Technical Committee on Structural and Proximity Fire Fighting Protectiv
3、e Clothing and Equipment and the Correlating Committee on Fire and Emergency Services Protective Clothing and Equipment, and was issued by the Standards Council on March 7, 2013, with an effective date of March 27, 2013. A Tentative Interim Amendment is tentative because it has not been processed th
4、rough the entire standards-making procedures. It is interim because it is effective only between editions of the standard. A TIA automatically becomes a public input of the proponent for the next edition of the standard; as such, it then is subject to all of the procedures of the standards-making pr
5、ocess. 1. Revise 2.3.3 to read as follows: ASTM F2412, Standard Test Method for Foot Protection, 2011. 2. Revise 5.1.7 to read as follows: 5.1.7 The following information shall also be printed legibly on each product label with all letters at least 1.5 mm (116 in.) in height: (1) Manufacturers name,
6、 identification, or designation (2) Manufacturers address (3) Country of manufacture (4) Manufacturers element identification number, lot number, or serial number (5) Month and year of manufacture, not coded (6) Model name, number, or design (7) Size or size range (8) Principal material(s) of constr
7、uction (9) Cleaning precautions 5.1.7.1 For garments only, where the principal material of construction is a component that is listed, the component name under which it is listed shall be identified. 5.1.7.2 For garments only, where the thermal liner, moisture barrier, and outer shell are separable,
8、 each separable layer shall also have a label containing the information required in 5.1.7(4) through 5.1.7(8). 5.1.7.3* For footwear only, principal materials of construction shall include at least the outer shell, moisture barrier, and thermal liner materials. Generic names of materials shall be u
9、sed. Additional materials that are used throughout the majority of the boot shall also be listed on the label. 5.1.7.4* For helmets only, principal materials of construction shall include generic terminology for the shell material provided. 5.1.7.5* For gloves only, principal materials of constructi
10、on shall include at least outer shell, moisture barrier, thermal liner, and wristlet materials. Generic names of materials shall be used. The type of leather shall be listed, such as cow leather, elk leather, and so forth. Additional materials that are used throughout the majority of the glove body
11、shall also be listed on the label. 3. Delete existing 5.1.8 through 5.1.11. 4. Revise Paragraph 7.7.7 to read as follows: 7.7.7 The glove interface component composite, including, but not limited to, trim, external labels, and external tags, but excluding hardware and hook and pile fasteners that do
12、 not directly contact the wearers body, shall be tested for resistance to flame as specified in Section 8.4, Flame Resistance Test 3, and shall not have an average char length of more than 100 mm (4 in.), shall not have an average afterflame of more than 2.0 seconds, shall not melt or drip, and shal
13、l not have the amount of consumed materials exceed 5 percent. 5. Revise Paragraph 7.7.8 to read as follows: 7.7.8 The glove extension composite, including, but not limited to, trim, external labels, and external tags, but excluding hardware and hook and pile fasteners that do not directly contact th
14、e wearers body, shall be tested for resistance to flame as specified in Section 8.4, Flame Resistance Test 3, and shall not have an average char length of more than 100 mm (4 in.), shall not have an average afterflame of more than 2.0 seconds, shall not melt or drip, and shall not have the amount of
15、 consumed materials exceed 5 percent. 6. Revise 7.10.9 to read as follows: 7.10.9 Footwear soles and heels shall be tested for resistance to abrasion as specified in Section 8.23 Abrasion Resistance Test, and the relative volume loss shall not be greater than 250 mm3. 7. Revise 7.13.6 to read as fol
16、lows: 7.13.6 Hoods shall be individually tested for resistance to shrinkage as specified in Section 8.24, Cleaning Shrinkage Resistance Test, and shall not exhibit shrinkage of more than 5 percent. 8. Revise 8.1.11.4 and add a new Table 8.1.11.4(c) to read as follows: 8.1.11.4 The wash cycle procedu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NFPA1971AMD22013STANDARDONPROTECTIVEENSEMBLESFORSTRUCTURALFIREFIGHTINGANDPROXIMITYFIREFIGHTINGEFFECTIVEDATE3272013PDF

链接地址:http://www.mydoc123.com/p-1008410.html