欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    ASTM F1523-1994(2013) Standard Guide for Selection of Booms in Accordance With Water Body Classifications《按照水体特性选择水栅的标准指南》.pdf

    • 资源ID:535078       资源大小:57.96KB        全文页数:2页
    • 资源格式: PDF        下载积分:5000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要5000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    ASTM F1523-1994(2013) Standard Guide for Selection of Booms in Accordance With Water Body Classifications《按照水体特性选择水栅的标准指南》.pdf

    1、Designation: F1523 94 (Reapproved 2013)Standard Guide forSelection of Booms in Accordance With Water BodyClassifications1This standard is issued under the fixed designation F1523; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the

    2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers the selection of containment boomthat may be used to control spills of oil and other substa

    3、ncesthat float on a body of water.1.2 This guide does not address the compatibility of spillcontrol equipment with spill products. It is the users respon-sibility to ensure than any equipment selected is compatiblewith anticipated products.1.3 The values stated in SI units are to be regarded as thes

    4、tandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the appl

    5、ica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D751 Test Methods for Coated FabricsF625 Practice for Classifying Water Bodies for Spill ControlSystemsF715 Test Methods for Coated Fabrics Used for Oil SpillControl and StorageF1093 Test Methods for Tensile

    6、 Strength Characteristics ofOil Spill Response Boom3. Summary of Guide3.1 Recommendations for the selection of spill containmentbooms are given for five key boom characteristics that affectperformance for each of four water body types (see Table 1).Notes accompanying Table 1 discuss the qualifying f

    7、actorsassociated with the minimum values listed, as well as thesignificance of the values as minimums. Classification criteriafor the four water body types are given in Practice F625.4. Significance and Use4.1 This guide is to be used to assist in the selection ofcontainment boom in accordance with

    8、water body classifica-tions.4.2 A small number of key parameters that generally affectboom performance have been used in Table 1, in order toenable the user to readily identify general criteria for boomselection.4.3 Many factors, other than those listed in Table 1, may beimportant in selecting conta

    9、inment boom for a particularapplication. Such factors include: flotation element length,wave length, the effect of stronger than minimum requiredstrength members, shock loads, abrasion resistance, stability inroll, resistance to bridging, interval between anchor points andhand holds, use of reflecto

    10、rs or lighting, compatibility withfresh or salt water, and resistance to sunlight exposure.4.4 The values given in Table 1 are the recommendedminimums for general purpose booms. As identified in 2.3,operational considerations may require trade-offs in boomproperties. Special purpose booms, and gener

    11、al purpose boomsused in special circumstances, may perform effectively withboom property values above or below those recommended inTable 1.4.5 Effective operation of oil spill control equipment de-pends on many factors, of which the prevailing environmentalconditions are just a few. Factors such as,

    12、 but not limited to,deployment techniques, level of training, personnelperformance, and mechanical reliability can also affect equip-ment performance.5. Keywords5.1 boom; oil spill; oil spill control equipment1This guide is under the jurisdiction of ASTM Committee F20 on HazardousSubstances and Oil

    13、Spill Responseand is the direct responsibility of SubcommitteeF20.11 on Control.Current edition approved April 1, 2013. Published July 2013. Originallyapproved in 1994. Last previous edition approved in 2007 as F1523 94 (2007).DOI: 10.1520/F1523-94R13.2For referenced ASTM standards, visit the ASTM w

    14、ebsite, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United St

    15、ates1ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights

    16、, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional st

    17、andardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Co

    18、mmittee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveadd

    19、ress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).TABLE 1 Recommendations for Selection of Spill Containment Boom

    20、sBoom PropertyACalm Water Calm Water-Current Protected Water Open Waterheight (range)B, mm (in.) 150 to 600 200 to 600 450 to 1100 900 to 2300+(6 to 24) (8 to 24) (18 to 42) (36 TO 90+ )minimum gross buoyancy to weight ratioC3:1 4:1 4:1 8:1minimum total tensile strengthD, N (lbs) 6800 23 000 23 000

    21、45 000(1500) (5000) (5000) (10 000)minimum fabric tensile strengthE, N/50 mm (lbs/in.) (2 TM): 2600 (300) 2600 (300) 2600 (300) 3500 (400)(1 TM): 2600 (300) 2600 (300) 3500 (400) 3500 (400)minimum fabric tear strengthF, N (lbs) 450 450 450 450(100) (100) (100) (100)AThe values given in parentheses a

    22、re provided for information purposes only.BThe boom dimensions are given as total height, with an assumed freeboard of 33 % (minimum) of boom height for calm, protected, and open water, and a freeboardof up to 50 % of height for calm water-current. Within the range of boom heights cited, values shou

    23、ld be selected in accordance with the specific conditions of the applicationconsidering such factors as: predominant wave conditions, volume of containment, length of boom required, tension on boom, etc.CValues shown for all water body classifications are the minimums for general purpose booms inten

    24、ded for spill response use. Special purpose booms designed forpermanent installations, booms employing balanced upper and lower tension members, and external tension member booms may employ hydrodynamic properties tomaintain adequate freeboard and therefore require lower buoyancy to weight ratios, b

    25、ut in no case should the buoyancy to weight ratio be less than 2:1. Buoyancy to weightratios greater than those listed may result in improved boom performance under certain conditions, however, further research is required before minimum values greaterthan those shown can be established.DThe dominan

    26、t variables in calculations of forces on deployed boom are current/tow speeds and boom draft. The specified values represent the developed tension on300 m (1000 ft) lengths of boom, deployed in a typical catenary configuration with a gap ratio of 1:3, with environmental data selected per water body

    27、classification, witha current/tow speed of 1 to 2 knots (4 kts for calm water-current), and, most significantly, the minimum boom draft per category. Booms with greater drafts should havehigher tensile strengths as follows: calm water 57 N/mm of draft (320 lbs/in.), calm water-current 140 N/mm (800

    28、lbs/in.), protected water 64 N/mm (360 lbs/in.), and openwater 72 N/mm (400 lbs/in.). It is recommended that greater tensile strengths be used for applications where booms may be subjected to greater current/tow speeds thanthose noted above, or where additional safety factors are warranted. The boom

    29、 tensile strength is tested in accordance with Test Methods F1093.EThe fabric tensile strength requirement is shown for two basic boom designs: two tension members (2 TM) and one tension member (1 TM). Membrane material is testedin accordance with Test Methods F715 and D751 (Breaking Strength, Proce

    30、dure A: Grab Test Method). Boom that employs load carrying fabric, that is, zero tensionmembers, must meet the total tensile strength requirement previously identified.FThe membrane material is tested in accordance with Test Methods F715 and D751 (Tearing Strength, Procedure B: Tongue Tear Test Meth

    31、od). Certain special-use fabricshave fabric tear strengths less than the values listed, such fabrics may be preferable for certain applications such as, resistance to particular spill products, sunlight, andabrasion, and would be acceptable as long as minimum fabric tensile strength requirements are met.F1523 94 (2013)2


    注意事项

    本文(ASTM F1523-1994(2013) Standard Guide for Selection of Booms in Accordance With Water Body Classifications《按照水体特性选择水栅的标准指南》.pdf)为本站会员(sofeeling205)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开