欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    ASTM D6502-2010(2015) 9534 Standard Test Method for Measurement of On-line Integrated Samples of Low Level Suspended Solids and Ionic Solids in Process Water by X-Ray Fluorescence .pdf

    • 资源ID:522702       资源大小:111.96KB        全文页数:6页
    • 资源格式: PDF        下载积分:5000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要5000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    ASTM D6502-2010(2015) 9534 Standard Test Method for Measurement of On-line Integrated Samples of Low Level Suspended Solids and Ionic Solids in Process Water by X-Ray Fluorescence .pdf

    1、Designation: D6502 10 (Reapproved 2015)Standard Test Method forMeasurement of On-line Integrated Samples of Low LevelSuspended Solids and Ionic Solids in Process Water byX-Ray Fluorescence (XRF)1This standard is issued under the fixed designation D6502; the number immediately following the designati

    2、on indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the operati

    3、on, calibration, anddata interpretation for an on-line corrosion product (metals)monitoring system. The monitoring system is based on x-rayfluorescence (XRF) analysis of metals contained on membranefilters (for suspended solids) or resin membranes (for ionicsolids). Since the XRF detector is sensiti

    4、ve to a range ofemission energy, this test method is applicable to simultaneousmonitoring of the concentration levels of several metalsincluding titanium, vanadium, chromium, manganese, iron,cobalt, nickel, copper, zinc, mercury, lead, and others in aflowing sample. A detection limit below 1 ppb can

    5、 be achievedfor most metals.1.2 This test method includes a description of the equipmentcomprising the on-line metals monitoring system, as well as,operational procedures and system specifications.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are incl

    6、uded in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior t

    7、o use.2. Referenced Documents2.1 ASTM Standards:2D1066 Practice for Sampling SteamD1129 Terminology Relating to WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3370 Practices for Sampling Water from Closed ConduitsD3864 Guide for On-Lin

    8、e Monitoring Systems for WaterAnalysisD4453 Practice for Handling of High Purity Water SamplesD5540 Practice for Flow Control and Temperature Controlfor On-Line Water Sampling and AnalysisD6301 Practice for Collection of On-Line CompositeSamples of Suspended Solids and Ionic Solids in ProcessWater3.

    9、 Terminology3.1 Definitions:3.1.1 For definitions of other terms used in this standard,refer to Terminology D1129 and Guide D3864.3.2 Definitions of Terms Specific to This Standard:3.2.1 emission intensity, nthe measure of the amplitude offluorescence emitted by a sample element.3.2.1.1 DiscussionTh

    10、is measurement is correlated with acalibration curve for quantitative analysis. The emission inten-sity generally is given in units of counts per second (c/s).3.2.2 excitation source, nthe component of the XRFspectrometer, providing the high-energy radiation used toexcite the elemental constituents

    11、of a sample, leading to thesubsequent measured fluorescence.3.2.2.1 DiscussionThe excitation source may be an elec-tronic x-ray generating tube or one of a variety of radioisotopesemitting an x-ray line of a suitable energy for the analysis athand.3.2.3 integrated sample, nthe type of sample collect

    12、ed byconcentrating the metal constituents of a water sample using afilter or an ion-exchange resin.3.2.3.1 DiscussionThese samples typically are collectedover long time periods (up to several days). The result ofanalysis of the collection medium yields a single measurement,which, when divided by the

    13、 total sample volume, is interpretedas the average metals concentration during the time of collec-tion.1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.03 on Sampling Water andWater-Formed Deposits, Analysis of Water for P

    14、ower Generation and Process Use,On-Line Water Analysis, and Surveillance of Water.Current edition approved April 1, 2015. Published April 2015. Originallyapproved in 1999. Last previous edition approved in 2010 as D6502 10. DOI:10.1520/D6502-10R15.2For referenced ASTM standards, visit the ASTM websi

    15、te, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States

    16、13.2.4 ionic solids, nmatter that will pass through a 0.45m filter and may be captured on anion or cation ion-exchangemembranes, or both.3.2.5 suspended solids, nmatter that is removed by a 0.45m filter.3.2.6 x-ray fluorescence (XRF) spectroscopy, nan analyti-cal technique in which sample elements a

    17、re irradiated by ahigh-energy source to induce a transition from the ground stateto an excited state.3.2.6.1 DiscussionThe excitation source is in the 5 to 50KeV x-ray range. The resulting transition elevates an inner-shell electron to one of several outer shells. The excited state isunstable and th

    18、ose excited elements will spontaneously dropback to their ground state with a concurrent emission offluorescent radiation. The energy (or wavelength) of thefluorescence is unique for each element, so the position of theemission lines on the energy scale serves to identify theelement(s). Then, the in

    19、tensity of an emission peak may beused, with proper calibration methods, to determine the con-centration of an element in the sample.3.3 Acronyms:3.3.1 EDXRF, nenergy-dispersive x-ray fluorescence3.3.2 WDXRF, nwavelength-dispersive x-ray fluorescence4. Summary of Test Method4.1 The concentrations of

    20、 particulate, or dissolved metals,or both, in water streams are determined through accumulationon appropriate collection media (filters or ion exchange mate-rials) and detection by x-ray fluorescence spectroscopy, pro-viding real time determination of iron and other metals foundin water streams. The

    21、 water sample delivered into the moni-toring system passes through a flow sensor, and then, to a flowcell assembly containing a membrane or resin filter, dependingon the application of interest. For an application where onlydissolved metals are to be analyzed, the sample needs to befiltered upstream

    22、 of the sample chamber to prevent particulatecontamination of the resin membrane surface. Asample bypassvalve is used for flow control through the sample chamber. Twosample chambers in sequence can be used to determine bothparticulate and dissolved components of the metal(s) of inter-est. X-ray fluo

    23、rescence is used to determine the concentrationof the captured material. XRF analysis gives a measure of totalelemental concentration independent of the oxidation state ormolecular configuration of the element. Elements with atomicnumbers 13 through 92 can be detected.4.2 The filter chamber is essen

    24、tially a variation of thetraditional corrosion product sampler used to collect integratedsamples (see Practice D6301). The main difference in thedesign of the flow cell in the on-line monitor is that the sampleenters the filter chamber in a way that allows an x-ray probe tobe positioned in close pro

    25、ximity to the filter or resin membranesurface.4.3 Since even a small quantity of water covering a samplesignificantly attenuates both the excitation and emissionradiation, a computer controlled valve switching system isincorporated into the monitor. In one position, this valve allowssample flow to p

    26、roceed through the monitoring unit and metalsto accumulate on the filter or resin membrane while the flowtotal is monitored. In the other position, the valve introduces airor other gas to purge the filter chamber of liquid while thesample is diverted to drain. It is during the air purge that thex-ra

    27、y measurement takes place. In this way, the monitoroperates by continuously alternating between two modes: asample accumulation mode and an analysis mode. Typical timeassignments for these modes for sample concentrations in thelow ppb range are five minutes each; thus, in one cycle, sampleaccumulate

    28、s for five minutes followed by a five minute x-raymeasurement. With various delays for valve switchingoperations, computer extraction of x-ray data, and datemanipulation, the measurement cycle in this case lasts approxi-mately 14 minutes. Sample accumulation and analysis timesare program variables,

    29、which may be adjusted prior to eachmonitoring session.Amonitoring session typically lasts severaldays for high purity water such as secondary feedwater fornuclear steam generators.5. Significance and Use5.1 Corrosion products, in the form of particulate anddissolved metals, in the steam and water ci

    30、rcuits of electricitygenerating plants are of great concern to power plant operators.Aside from indicating the extent of corrosion occurring in theplant, the presence of corrosion products has deleterious effectson plant integrity and efficiency. Deposited corrosion productsprovide sites at which ch

    31、emicals, which are innocuous at lowlevels, may concentrate to corrosive levels and initiate under-deposit corrosion. Also, corrosion products in feedwater enterthe steam generating components where deposition on heattransfer surfaces reduces the overall efficiency of the plant.5.2 Most plants perfor

    32、m some type of corrosion productmonitoring. The most common method is to sample for longtime periods, up to several days, after which laboratoryanalysis of the collected sample gives the average corrosionproduct level over the collection time period. This methodol-ogy is referred to as integrated sa

    33、mpling. With the morefrequent measurements in the on-line monitor, a time profile ofcorrosion product transport is obtained. Transient high corro-sion product levels can be detected and measured, whichcannot be accomplished with integrated sampling techniques.With this newly available data, plant op

    34、erators may begin tocorrelate periods of high corrosion product levels with control-lable plant operating events. In this way, operators may makemore informed operational decisions with respect to corrosionproduct generation and transport.6. Interferences6.1 Coincidence of Certain Emission LinesIn X

    35、RF, eachelement emits fluorescence at characteristic wavelengths whichmakes element identification unambiguous; however, certainpairs of emission lines from different elements occur suffi-ciently close in energy that the resulting overlap causesdifficulties in quantitative analysis. An example of th

    36、is is theK line of cobalt, which occurs at 6.925 keV (average) and theK line of iron, which occurs at 7.059 keV (average). In thecase of a small amount of cobalt in the presence of a largeamount of iron, which is a typical case among corrosionD6502 10 (2015)2product samples from steam generating pla

    37、nts, the cobaltanalysis is hindered by the iron in the sample. Note that iron isnot similarly affected by the presence of cobalt since the ironK line may be isolated to extract iron emission intensity.6.1.1 There are three strategies which may be used toameliorate the type of interference described

    38、above. First, theratio of K to K emission intensity is constant and known foreach element; thus, from a higher than expected intensity ofiron K emission, relative to the K emission, the presence ofcobalt may be inferred and measured. Second, the use of acryogenically cooled, solid-state detector gre

    39、atly improves theresolution (by reducing the band width of individual emissionpeaks) such that direct measurement of cobalt is possible.Third, the use of wavelength dispersive XRF (WDXRF)instrumentation provides the optimum line separation;however, WDXRF instrumentation is much more expensive,and le

    40、ss robust for on-line use, than energy dispersive XRF(EDXRF) spectrometers.7. Apparatus7.1 The on-line metals analyzer3consists of the followingmain components: x-ray probe and associated electronics, flowcell and filter chamber, flow totalizer, valve switching system,and instrument control and data

    41、 acquisition system.7.2 The volume of sample delivered to the flow cell assem-bly is monitored using a flow totalizer. Several varieties ofthese are available including piston, turbine, and Coriolistypes. The flow totalizer should have capability for computercommunication.7.3 The water sample is pas

    42、sed through a specially designedfilter chamber containing a membrane filter (typically 0.45micron, to remove particulates) or an ion exchange resinmembrane (for dissolved components).Above the filter or resinmembrane surface, an x-ray transparent material, for example,kapton or beryllium, fitted wit

    43、h O-rings, confines the watersample within the filter cavity and provides the windowthrough which x-ray analysis proceeds. In this way, frequentmeasurements (several per hour) are made of the incrementalaccumulation of metals while the filter or resin membraneremains in service.7.4 The x-ray probe c

    44、onsists of both the excitation source toirradiate the sample and the detection device for returningfluorescence. The excitation source may be an electronic x-raytube or a suitably chosen radioisotope. For efficient excitation,the excitation energy should be 1.5 to 2 times the fluorescentenergy of th

    45、e element(s) being monitored. For example, ironwhich fluoresces at 6.4 keV should be irradiated with a sourcein the range of 10 to 13 keV. Many x-ray tubes have variablepower capability so voltage and amperage may be adjusted tooptimize the analysis at hand. Alternatively, for iron analysis,an appro

    46、priate choice of radioisotope as an excitation source iscurium-244 (Cm-244), which emits a line at approximately 12keV.7.5 For each measurement cycle, the following informationis recorded in a continuously updated data file in the control-ling personal computer (PC): date, time, mass measurement for

    47、each metal of interest, volume increment, and raw intensitydata. The on-line control program, as well as several auxiliaryprograms, operate under the Microsoft Windows platform. ThePC controls all aspects of monitor operation and stores allcollected data. Monitoring results appear on the PC screen i

    48、nreal time during a monitoring session, as well as, being storedin continuously updated files in a subdirectory of the userschoice.7.6 The data files generated during an on-line sessionrepresent a record of cumulative metal mass as a function ofcumulative sample volume during the course of the sessi

    49、on.Since the units of these parameters are micrograms and litersrespectively, the slope through the data at any point gives themetal concentration in ppb. A separate program, residing in thesame Windows group as the on-line control program, automati-cally converts the raw data to ppb values as a function of time.7.7 Aschematic diagram of a typical configuration is shownin Fig. 1. This configuration shows only one channel orsampling system. Additional channels can be incorporatedreadily into the monitoring system.7.8 Each channel comprises a separate flow cell


    注意事项

    本文(ASTM D6502-2010(2015) 9534 Standard Test Method for Measurement of On-line Integrated Samples of Low Level Suspended Solids and Ionic Solids in Process Water by X-Ray Fluorescence .pdf)为本站会员(赵齐羽)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开