1、MIL-L-5567F (2) 42 m 777770b 0233286 7 MIL-L-5567F AMENDMENT 2 7 November 1986 SUPERSEDING AMENDMENT 1 5 October 1984 MILITARY SPECIFICATION LIFE RAFTS, INFLATABLE-4 AND 7 MAN-FOR AIRCRAFT USE This amendment forms a part of Mi li tary Specification-MIL-L-5567F, dated 7 Jan 1983 and is approved for u
2、se by all Department and Agencies of the Department of the Defense. PAGE 3 2.1.2, Drawi ngs-Naval Air Systems Command Add: “62A82H601-Carrying Case Assembly, LRU-l3/A Life Raft“ PAGE 10 * 3.9.1.1, delete and substitute: “3.9.1.1 Flange adhesion to the spool and flange strength. The molded rubber fla
3、nge on the topping-off valve shall not strip away from the brass spool of the topping-off valve nor shall the rubber flange fail when tested as specified in 4.7.1.“ PAGE 17 * 4.7.1, delete and substitute: “4.7.1 Flange adhesion to the spool and flange strength. The adhesion of the topping-off valve
4、flange to the spool and the flange strength shall be determined on a suitable testing apparatus operating with the movable jaw separating at a rate of 2 flange shall be slit into six equal segments and two diametrically opposite segments shall be clamped in the jaws of the test apparatus. pounds sha
5、ll be applied and the segments shall be observed for conformance to the requirements of 3.9.1.1. remaining two diametrically opposite segments.“ 1/8 inches per minute under no load. The rubber A load of 75 This inspection shall be repeated for each PAGE 19 4.7.4 , In the eighth line delete 10“ and s
6、ubstitute “15“. AMSC - NIA 1 of 2 FSC 4220 DISTRIBUTION STATEMENT A. Approved for pub1 ic release; di stri but.ion is un1 imi ted. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-L-5567F (2) YE &i 7777706 0233287 O MIL-L-5567F AMENDMENT 2 PAGE 26
7、 * TABLE III - Sample Size, Acceptance Criteria, (See 4.5.1.2) Delete the Sample size information for the Visual Examination Inspection and substi tute: “a. Every life raft for critical defects b. Inspection Level II $1 for minor defects“. Delete the Acceptance Criteria information for the Visual Ex
8、amination Inspection and substitute: “a. Reject all units with any critical defects b. An acceptable quality level of 150.0 defects per hundred units for minor defects“. Under the Sample Size column for the Dimensional Check Inspection delete “S-3“ and substitute “S-3 A/“ Under the Acceptance Criter
9、ia column for Dimensional Check Inspection delete 100“ and substi tue “150.0“ Delete the Sample Size information for the Weight Inspection and substitute: “Inspection Level S-3 4, ,e- Delete the Acceptance Criteria information for the Weight Inspection and substitue: “An acceptable quality level of
10、2.5 percent defective.“ Under the Sample Size column for the Packaging Inspection delete IS-2“ and substi tute “S-2 A/“ * The margins of this amendment are marked with an asterisk to indicate where changes (additions, modifications, corrections, deletions) from the previous amendment were made. This
11、 was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationships to the last previous amendment. Custodians: Navy - AS Air Force - 99 Army - ME Preparing activity: Navy - AS Project No. (4220-0321) Review activities Air Force - 84 2 of 2 / Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-