欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    NASA-TN-D-7185-1973 Theoretical and experimental internal flow characteristics of a 13 97-centimeter-diameter inlet at STOL takeoff and approach conditions《在短距起飞和接近条件下13 97 cm直径的理论.pdf

    • 资源ID:836905       资源大小:1,006.96KB        全文页数:24页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    NASA-TN-D-7185-1973 Theoretical and experimental internal flow characteristics of a 13 97-centimeter-diameter inlet at STOL takeoff and approach conditions《在短距起飞和接近条件下13 97 cm直径的理论.pdf

    1、NASA TECHNICAL NOTE IMfZfiK Sonic inlet; Induction system;Pressure distribution; Potential flow; Bound-ary layer flow; Compressibility correction;STOL aircraft18. Distribution StatementUnclassified - unlimited19. Security Classif. (of this report)Unclassified20. Security Classif. (of this page)Uncla

    2、ssified21. No. of Pages2222. Price*$3.00 For sale by the National Technical Information Service, Springfield, Virginia 22151Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-THEORETICAL AND EXPERIMENTAL INTERNAL FLOW CHARACTERISTICSOF A 13.97-CENTIMETE

    3、R-DIAMETER INLET AT STOLTAKEOFF AND APPROACH CONDITIONSby James A. AlbersLewis Research CenterSUMMARYThe theoretical and experimental internal flow characteristics of a 13. 97-centimeter-diameter inlet with centerbody refracted and extended are presented at STOLtakeoff and approach operating conditi

    4、ons. The theoretical results are obtained fromincompressible potential flow corrected for compressibility and boundary layer. Com-parisons between theoretical internal surface pressure distributions and experimentaldata are presented for free-stream velocities of 0, 24, 32, and 45 meters per secondf

    5、or a range of inlet incidence angles from 0 to 50. Surface static-pressure distribu-tions are illustrated at circumferential locations of 0, 60, 120, and 180. SurfaceMach number distributions from stagnation point to diffuser exit are presented alongwith turbulent boundary layer shape factors.The re

    6、sults indicate a large circumferential variation in surface static pressuresat the inlet highlight and throat at large incidence angles. Only small circumferentialvariations in surface static pressure occurred in the last 50 percent of the diffuser.The largest diffuser adverse pressure gradients occ

    7、urred on the windward side of theinlet and at the highest incidence angle. A 45-per cent increase in local surface Machnumber (52-percent decrease in surface static pressure) was obtained as incidence anglewas increased from 0 to 40. Local theoretical surface Mach numbers as high as 1. 45were found

    8、on the windward side of the inlet. Extending the centerbody of the inlet for-ward resulted in large regions of local sonic velocities in the throat of the inlet. Ingeneral, the theoretical and experimental surface static pressure distributions agreed.However, at the inlet highlight the theoretical s

    9、tatic pressures were generally lower !than the experimental data.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-INTRODUCTIONCurrently, there is much interest in the design and understanding of inlets for sub-sonic aircraft. The inlet must be designe

    10、d to supply high pressure recovery and uni-form flow to the engine compressor during low-speed and cruise operation. Engineoperation can be adversely affected by circumferential distortions, occurring mainlywhen the airplane is operating at high angles of attack or yaw (ref. 1). Because of thehigh l

    11、ift coefficients and low speed necessary for takeoff and landing operation of STOLaircraft, the engine inlet will be exposed to larger upwash angles than conventional air-craft (ref. 2). In addition, the engine inlet may be exposed to crosswinds as large as13 to 18 meters per second (ref. 3). These

    12、large incidence angles result in large ad-verse pressure gradients over a large portion of the internal diffuser surface. Theselarge adverse pressure gradients may cause either laminar or turbulent separation. Ingeneral, the designer tries to avoid flow separation on the inlet surface in order toach

    13、ieve high pressure recovery and uniform flow at the compressor face. Little exper-imental information on nacelle inlets at incidence angles other than zero is currentlyavailable. Also, accurate methods for estimating surface pressure distributions andboundary layer characteristics are needed to do d

    14、etailed design studies of inlets forSTOL aircraft.1 This report presents theoretical and experimental internal flow characteristics ofa 13. 97-centimeter-diameter inlet at STOL takeoff and approach conditions. The theo-retical methods used in this investigation include both potential flow and bounda

    15、ry-layerflow for axisymmetric inlets. The experimental data were obtained from wind tunneltests of the translating centerbody inlet reported in reference 4. The inlet configuration(fig. 1) is a representative geometry for STOL applications. Details of the inlet geom-etry are given in reference 4. Co

    16、mparisons between internal surface pressure distri-butions and experimental data are presented for free stream velocities of 0, 24, 32,and 45 meters per second for a range of incidence angles from 0 to 50. Mass flowrates through the inlet ranged from 90 to 103 percent of design. The design corrected

    17、flow rate was 2. 49 kilograms per second. Location of stagnation points on the inlet lipand surface Mach number distributions are presented along with turbulent boundary-layer shape factors. The effect of centerbody location on surface static pressures is. also illustrated.METHOD OF ANALYSISThe inco

    18、mpressible potential flow solution for axisymmetric inlets is the basis ofan analytical tool to design inlets for STOL applications. The incompressible potentialProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-flow solution was obtained by the method

    19、of reference 5. This solution yields velocityand static pressures on the surface of the inlet for any combination of free-streamvelocity, inlet incidence angle, and mass flow rate through the inlet. The method ofreference 5 is based on the Douglas potential flow method (ref. 6). The incompressiblepo

    20、tential flow solution can be refined by including the effects of compressibility andboundary layer.Compressibility CorrectionHigh subsonic or supersonic flows exist on STOL engine inlets at takeoff and ap-proach operating conditions. Thus, a compressibility correction should be made to theincompress

    21、ible velocity. A compressibility correction applicable to nacelle inlets isdiscussed in reference 7, which proposed an empirical relation between the local incompressible velocity V- and the local compressible velocity V_. It is expressed as1 txwherep. incompressible density, which is equal to stagn

    22、ation densityp average compressible density across flow passageV- average incompressible velocity across flow passage at given stationThis relation was used in this investigation.Boundary-Layer FlowThe surface Mach number distributions obtained from the potential flow solutionwere used as an input t

    23、o the boundary-layer analysis to determine its growth and sepa-ration (if any) on the inlet surface. The method of Herring and Mellor (ref. 8) was cho- sen to calculate both laminar and turbulent boundary-layer growth because of its accu-racy, physical soundness, and adaptability to the present prob

    24、lem. The effective-viscosity hypothesis of Mellor and Herring should be applicable for high adverse gradientflows encountered for inlets during low-speed operation. A more detailed discussion ofthis hypothesis is given in reference 9.Provided by IHSNot for ResaleNo reproduction or networking permitt

    25、ed without license from IHS-,-,- In order to compute a boundary-layer solution, it was necessary to prescribe thevelocity profile at the start of the calculation, namely, the stagnation point on the inlet.Because the flow in the immediate neighborhood of the forward stagnation point is bothlaminar a

    26、nd incompressible, laminar similarity solutions were applicable. TheFalkner-Skan laminar wedge flow solution (ref. 10) for stagnation point flow was usedfor a starting profile. This initial profile was calculated in the computer program ofreference 8.In addition, the transition point from laminar to

    27、 turbulent flow must be located.The location of the transition point was based on theoretical considerations because ofthe lack of empirical methods that were applicable to the present problem. According cto Schlichting (ref. 10) the point of transition in the range of Reynolds numbers from 107to 10

    28、 almost coincides with the point of minimum pressure of the potential flow. Inthis report the transition was assumed to take place at the point of minimum pressure.Once the laminar and turbulent boundary-layer characteristics on the inlet lip anddiffuser are calculated, the location of the turbulent

    29、 separation point (if any) can be de-termined. The criteria used for turbulent separation are as follows: (1) adverse pres-sure gradient; (2) skin friction coefficient of approximately zero; (3) increase in shapefactor H as the separation point is approached; (4) a value of H of 2. 6 or greater im-m

    30、ediately ahead of the separation point.RESULTS AND DISCUSSIONSurface Static-Pressure DistributionsTheoretical surface static-pressure distributions are first compared with experi-mental data for conditions where the flow is generally well behaved (i.e., attached alongthe inlet surface). The two inle

    31、t geometries considered are shown in figure 1. All datacomparisons are made for the inlet with centerbody retracted (fig. l(a) unless statedotherwise. The effects of compressibility and boundary-layer displacement thicknesscorrection on the incompressible potential flow solution are first discussed.

    32、Effect of compressibility correction. - A comparison of the theoretical internalsurface static-pressure distributions with experimental data is shown in figure 2 forstatic conditions (V = 0). (Symbols are defined in the appendix.) The pressure distri-butions are presented from the inlet highlight (X

    33、/L = 0) to the diffuser exit (X/L = 1- )-The incompressible potential flow solution (the dashed line) yields static pressures ap-proximately 12 percent higher than experimental data near the inlet highlight and approx-imately 5 percent higher in the aft portion of the diffuser. The incompressible po

    34、tentialflow solution overestimates the static pressure because of the high surface Mach num-bers (up to 0. 9). The incompressible potential flow solution with the compressibilityProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-correction is shown in f

    35、igure 2 (solid line). The theory with the compressibility correc-tion generally compares well with the experimental data in the first half of the inlet.However, in the aft portion of the diffuser the theoretical static pressures are up to3 percent higher than experimental data.Effect of boundary-lay

    36、er displacement thickness correction. - A combined potentialflow and boundary-layer analysis improves the agreement between the experimental andtheoretical surface static-pressure distributions in the aft portion of the diffuser. Thisis illustrated for a static condition (V = 0) in figure 3(a) and f

    37、or a free-stream velocityof 24 meters per second at an incidence angle of 40 in figure 3(b). Adding the theoreti-cal boundary-layer displacement thickness to the inlet surface results in a decreasedflow passage cross-sectional area and hence an increase in the local surface Mach num-ber. The boundar

    38、y layer is thickest near the diffuser exit and hence affects the staticpressure most in this region. The increase in local surface Mach number yields a re-duced theoretical surface static pressure for the potential flow solution with a boundary-layer correction.With both the compressibility correcti

    39、on and boundary-layer correction, the theo-retical and experimental static pressures are in good agreement over the entire lengthof the diffuser. The boundary-layer correction is also effective in improving the solu-tion at incidence angle (fig. 3(b) in spite of the fact the boundary layer is not un

    40、iformlydistributed circumferentially in the aft portion of the diffuser.The boundary-layer correction is not included in the remaining theoretical staticpressures because of the large computation time required to make this correction.Hence, there are small discrepancies between the theory and experi

    41、ment in the aft por-tion of the diffuser in the subsequent figures.Circumferential variation. - The variation of the theoretical internal surface staticpressure along the diffuser surface for several circumferential angles j/ and for inci-dence angles of 20 and 40 is presented in figure 4. The circu

    42、mferential variation instatic pressure is greatest at the inlet highlight (X/L = 0) and decreases with increasingX/L. The circumferential variation in p/P, is small for X/L locations greater than0.5. The degree of the circumferential variation in static pressure increases as inci-dence angle is incr

    43、eased. At the inlet throat a 9 percent circumferential variation inP/POO occurs at an incidence angle of 20 (fig. 4(a), and a 16-percent variation occursat an incidence angle of 40 (fig. 4(b).Both the theoretical and the experimental circumferential variation of static pres-sure at several stations

    44、is shown in figure 5. The experimental static pressures gen-erally compare well with the theoretical pressures for all circumferential angles. Thelowest inlet lip static pressures and largest diffuser adverse pressure gradients occuron the windward side of the inlet (i/ =0). Thus, all remaining comp

    45、arisons will bemade at circumferential angle of / = 0.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Effect of flow variables. - To illustrate the applicability of the prediction methodover a wide range of conditions, a. comparison with experimental

    46、 data is made for vari-ous incidence angles, free-stream velocities, and mass flow rates. The effect of thethree flow variables on the theoretical static pressures is first discussed. This is fol-lowed by a discussion of the comparison between theory and experiment.The effect of incidence angle is i

    47、llustrated in figure 6 by the theoretical static-pressure distributions (with experimental data) at a free-stream velocity of 32 metersper second and for incidence angles of 0, 20, and 40. The value of the static-pressure ratio on the inlet lip decreases considerably as the incidence angle increases

    48、from 0 to 40. For example, the theoretical static-pressure ratio at the inlet highlightdecreases from 0. 57 at an incidence angle of 0 to 0. 30 at an incidence agle of 40.There is little change in the static-pressure prediction in the aft portion of the diffuser(X/L 0.4) as incidence angle is increa

    49、sed from 0 to 40. The large decrease in static -pressure ratio as incidence angle increases is related to the shift in the stagnation pointon the outer cowl surface on the windward side of the inlet. As the incidence angle in-creases from 0 (fig. 7(a) to 40 (fig. 7(c), the stagnation point moves further under thelower cowl external surface. This results in higher velocities and correspond


    注意事项

    本文(NASA-TN-D-7185-1973 Theoretical and experimental internal flow characteristics of a 13 97-centimeter-diameter inlet at STOL takeoff and approach conditions《在短距起飞和接近条件下13 97 cm直径的理论.pdf)为本站会员(twoload295)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开