欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    ISA 71 03-1995 Environmental Conditions for Process Measurement and Control Systems Mechanical Influences《过程测量和控制体系的环境条件 机械影响 原标准号ANSI ISA S71 03-1995》.pdf

    • 资源ID:789761       资源大小:116.97KB        全文页数:18页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    ISA 71 03-1995 Environmental Conditions for Process Measurement and Control Systems Mechanical Influences《过程测量和控制体系的环境条件 机械影响 原标准号ANSI ISA S71 03-1995》.pdf

    1、Environmental Conditionsfor Process Measurementand Control Systems:Mechanical InfluencesApproved 12 January 1995ANSI/ISAS71.031995AMERICAN NATIONAL STANDARDCopyright 1995 by the Instrument Society of America. All rights reserved. Printed in the UnitedStates of America. No part of this publication ma

    2、y be reproduced, stored in a retrieval system, ortransmitted in any form or by any means (electronic, mechanical, photocopying, recording, orotherwise), without the prior written permission of the publisher.ISA67 Alexander DriveP.O. Box 12277Research Triangle Park, North Carolina 27709ANSI/ISA-S71.0

    3、3, Environmental Conditions for Process Measurement and Control Systems: Mechanical InfluencesISBN: 1-55617-576-0ANSI/ISA-S71.03-1995 3PrefaceThis preface, as well as all footnotes and annexes, is included for informational purposes only and is not part of ANSI/ISA-S71.03.This standard has been prep

    4、ared as part of the service of ISA, the international society for measurement and control, toward a goal of uniformity in the field of instrumentation. To be of real value, this document should not be static but should be subject to periodic review. Toward this end, the Society welcomes all comments

    5、 and criticisms and asks that they be addressed to the Secretary, Standards and Practices Board; ISA; 67 Alexander Drive; P. O. Box 12277; Research Triangle Park, NC 27709; Telephone (919) 990-9227; Fax (919) 549-8288; e-mail: standardsisa.org.The ISA Standards and Practices Department is aware of t

    6、he growing need for attention to the metric system of units in general, and the International System of Units (SI) in particular, in the preparation of instrumentation standards, recommended practices, and technical reports. The Department is further aware of the benefits to USA users of ISA standar

    7、ds of incorporating suitable references to the SI (and the metric system) in their business and professional dealings with other countries. Toward this end, this Department will endeavor to introduce SI-acceptable metric units in all new and revised standards to the greatest extent possible. The Met

    8、ric Practice Guide, which has been published by the Institute of Electrical and Electronics Engineers as ANSI/IEEE Std. 268-1992, and future revisions, will be the reference guide for definitions, symbols, abbreviations, and conversion factors.It is the policy of ISA to encourage and welcome the par

    9、ticipation of all concerned individuals and interests in the development of ISA standards. Participation in the ISA standards-making process by an individual in no way constitutes endorsement by the employer of that individual, of ISA, or of any of the standards, recommended practices, and technical

    10、 reports that ISA develops.This document is one of several standards that address various environmental conditions affecting process measurement and control systems. In developing this standard, the committee goals included the following:1) To provide a practical standard that can be applied with a

    11、minimum of research and technical effort by the user.2) To provide a concise method of stating environmental classifications for convenient communications between all users of the standard.3) To cover real-world ranges of each classified parameter.The following people served as members of ISA Commit

    12、tee SP71:NAME COMPANYK. Gulick, Chairman Digital Equipment Corporation*M. Zielinski, Managing Director FisherRosemountD. Boyle Consultant*One vote per company4 ANSI/ISA-S71.03-1995NAME COMPANY*D. Brown FisherRosemountR. Calcavecchio ConsultantR. Cowles Union Camp CorporationE. Demers Foxboro Company

    13、L. Falat Westvaco Technical CenterR. Funwela U.S. SteelM. Hopkins KeyTek Instrument CorporationM. Huza Flanders/FCP MicroenvironmentalE. Lee U.S. Nuclear Regulatory AgencyL. Leonard ConsultantT. Mallory Power Safety InternationalC. Muller Purafil, Inc.A. Perkins Rhorback Cosasco SystemsJ. Saine Weye

    14、rhaeuser Company*T. Schey Allen-Bradley CompanyT. Shelton Westvaco CorporationK. Stickrod ABB*R. Turk Allen-Bradley CompanyJ. Vajda Modicon, Inc.*C. Yi FisherRosemountThis standard was approved for publication by the ISA Standards and Practices Board on January 2, 1995.NAME COMPANYM. Widmeyer, Vice

    15、President Washington Public Power Supply SystemH. Baumann H. D. Baumann, Inc.D. Bishop Chevron USA Production CompanyP. Brett Honeywell, Inc.W. Calder III Calder EnterprisesH. Dammeyer Phoenix Industries, Inc.R. Dieck Pratt shock class C1 would represent a class C location and a level 1 severity.4 D

    16、efinitions4.1 operating conditions, normal: The range of operating conditions within which an instrument is designed to operate and for which operating influences are stated.4.2 storage conditions: The conditions to which an instrument may be subjected prior to installation. Also included are the co

    17、nditions that may exist during shutdown. No permanent physical damage or impairment of operating characteristics shall take place under these conditions.5 Location classification5.1 Explanation of instrument locations and mechanical influence classesA broad distribution of shock and vibration levels

    18、 exists within industries that use process measurement and control equipment. Each of these levels may produce an effect that ranges between insignificant and catastrophic. The effects of shock and vibration depend on the type of equipment, method of application, and frequency of occurrence. They ar

    19、e also influenced by external factors such as temperature and corrosion. See ANSI/ISA-S71.01 and ANSI/ISA-S71.04 standards for Environmental Conditions for Process Measurement and Control Systems.ANSI/ISA-S71.03-1995 11Table 1 is set up in such a way as to classify exposures by environment type and

    20、frequency-acceleration response, as described in Annex A.5.2 Instrument locations5.2.1 Environment “A“ locations, defined as controlled mechanical influence environments, are those areas usually provided for sensitive process measurement and control systems that require a controlled environment.5.2.

    21、2 Environment “B“ locations, defined as uncontrolled mechanical influence environments, are process measurement and control system areas outside the controlled environment but not affected directly by the process.5.2.3 Environment “C“ locations, defined as uncontrolled mechanical influence environme

    22、nts, are process measurement and control system areas outside of the controlled area that are directly affected by the process.5.3 Class of mechanical influence5.3.1 Class 1, low severity This designation applies to an environment that is within the 90th percentile of the data recorded, as described

    23、 in Annex A.5.3.2 Class 2, moderate severityThis designation applies to an environment that is within the 95th percentile of the data recorded, as described in Annex A.5.3.3 Class 3, harsh severityThis designation applies to an environment that is within the 99th percentile of the data recorded, as

    24、described in Annex A.5.3.4 Class X, severeThis designation applies to an environment in which the mechanical influence causes total and unrecoverable loss of the use of an essential function. In this environment, the limit exceeds the 99th percentile of the data recorded and described in Annex A or

    25、is subject to negotiation between user and supplier.12 ANSI/ISA-S71.03-1995Table 1 Vibration1Refer to Annex A.2See 5.2 for definition of operating environment.3See 5.3 for definition of mechanical influence.4See 5.3 for percentile occurrence classification.5Constant acceleration measured in meters m

    26、/sec2. Divide by 9.81 to get acceleration in gs (based on value of gat sea level: g=9.81 m/sec2.)6Peak displacement measured in millimeters (mm).7Use peak displacement (s) below 8 Hz to 9 Hz. Use constant acceleration (a) above 8 Hz to 9 Hz.8TBS = To Be Specified.Table 2 Shock1TBS = To Be Specified2

    27、Not to exceed values listedOperation vibration classes, percentiles, and environment(1, 3, 7)Environment2Class3/Percentile41/90th 2/95th 3/99th X/SpecialConstant acceleration5/Peak displacement6VA 1.0/0.35 2.0/0.75 5.0/1.6 TBS8VB 2.0/0.75 5.0/1.6 10.0/3.5 TBSVC 10.0/3.5 20.0/7.5 50.0/16.0 TBSWeight

    28、(kg) Environment ClassFree fall Height(cm)1/2 sine acceleration2(m/sec2)200 SC1x30TBS20TBSANSI/ISA-S71.03-1995 136 Example of intended usage6.1 The manufacturer and/or user should specify the system performance in a stated environ-mental class. The following example shows how a manufacturer or user

    29、might specify several sets of environmental classes for operating or maintaining the same system.Example 1Conditions Shock and vibration classNormal operating conditions, vibrations VA2Normal operating conditions, shock SB1Storage and handling VC3 SC1 This example might be used by an instrument manu

    30、facturer to indicate the following:a) The system is designed to operate within a control room type of environment with a maximum indicated vibration mechanical influence class 2.b) The system is designed to operate at shock levels normally experienced by equipment located on the shop floor with a ma

    31、ximum indicated limit mechanical influence class 1.c) The system can be stored and handled with a vibration maximum indicated limit listed as class 3 and a shock maximum indicated limit listed as class 1.ANSI/ISA-S71.03-1995 15Annex A Vibration test programA.1 IntroductionIn the preparation of this

    32、series of standards that deal with environmental conditions for process measurement and control systems, it was determined that insufficient data were available to describe the vibration levels of operating instrumentation. Therefore, in conjunction with the preparation of this standard, a study was

    33、 conducted to gather vibration information through the process industry in the United States and Canada. The data gathered were used to establish the vibration tables of this standard.NOTE All raw test data used in the preparation of this standard are the property of ISA.The vibration analyzer that

    34、was purchased for this study is normally used on rotating machinery. After each series of tests, the analyzer was recalibrated to assure repeatability. A.2 Testing procedureA.2.1 Test equipmentThe accelerometer of the vibration analyzer was mounted to a magnet and was sensitive in the direction perp

    35、endicular to the force of the magnet. Measurements were taken on three planes for each location where equipment would normally be mounted. Peak acceleration was recorded for frequency ranges of 0-100 Hz and 0-2000 Hz.The field data were then processed to generate frequency-acceleration graphs and sh

    36、ow the 99th, 95th, and 90th percentiles for all the data collected in this program.A.2.2 Surfaces to be testedA device measurement requires that the vibration levels be recorded in three different directions.The accelerometer was mounted:a) perpendicular to the mounting surface;b) parallel to the mo

    37、unting surface; andc) perpendicular to the first two positions.A.2.3 Testing procedureAfter mounting the accelerometer, the test chart was placed in the platen, the battery level was checked, the range switch was set to 2000 Hz, and the test was started. The test was completed in about one minute. I

    38、f any information existed in the 0-200 Hz range, the pen color was changed, the range switched to 200 Hz, and the test run again.The test was repeated with the accelerometer placed in each of the positions listed in 2.2 above.16 ANSI/ISA-S71.03-1995A.2.4 Documentation of dataIn addition to specific

    39、test technician, date, and other relevant information, the following data were collected for each test.A.2.4.1 Process description: Identify industry and process as petroleum, pulp and paper, steel, mining, etc.A.2.4.2 Type: Identify application and instrument as temperature, pressure, flow, level,

    40、computer, etc.A.2.4.3 Type of mounting: State type and description such as pipe, floor, panel, rack, etc.A.2.4.4 Location Environmental: Specify exposed, sheltered, control room.A.2.4.5 Remarks: Describe anything that may have significantly influenced the test or the analysis of its results (e.g., t

    41、ruck passing during test).Developing and promulgating technically sound consensus standards, recommended practices, and technical reports is one of ISAs primary goals. To achieve this goal the Standards and Practices Department relies on the technical expertise and efforts of volunteer committee mem

    42、bers, chairmen, and reviewers.ISA is an American National Standards Institute (ANSI) accredited organization. ISA administers United States Technical Advisory Groups (USTAGs) and provides secretariat support for International Electrotechnical Commission (IEC) and International Organization for Standardization (ISO) committees that develop process measurement and control standards. To obtain additional information on the Societys standards program, please write:ISAAttn: Standards Department67 Alexander DriveP.O. Box 12277Research Triangle Park, NC 27709ISBN: 1-55617-576-0


    注意事项

    本文(ISA 71 03-1995 Environmental Conditions for Process Measurement and Control Systems Mechanical Influences《过程测量和控制体系的环境条件 机械影响 原标准号ANSI ISA S71 03-1995》.pdf)为本站会员(王申宇)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开