欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    EN ISO 16014-5-2012 en Plastics - Determination of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography - Part 5 Method using ligh.pdf

    • 资源ID:725814       资源大小:1.43MB        全文页数:36页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    EN ISO 16014-5-2012 en Plastics - Determination of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography - Part 5 Method using ligh.pdf

    1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN ISO 16014-5:2012Plastics Determination ofaverage molecular mass andmolecular mass distribution ofpolymers using size-exclusionchromatographyPart 5: Method using light-scatt

    2、eringdetection (ISO 16014-5:2012)BS EN ISO 16014-5:2012 BRITISH STANDARDNational forewordThis British Standard is the UK implementation ofEN ISO 16014-5:2012.The UK participation in its preparation was entrusted to Technical Committee PRI/21, Testing of plastics.A list of organizations represented o

    3、n this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2012. Published by BSI Standards Limited 2012ISBN 978 0 580 65053

    4、 6 ICS 83.080.01 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 July 2012.Amendments issued since publicationDate T e x t a f f e c t e dEUROPEAN STANDARD NO

    5、RME EUROPENNE EUROPISCHE NORM EN ISO 16014-5 July 2012 ICS 83.080.01 English Version Plastics - Determination of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography - Part 5: Method using light-scattering detection (ISO 16014-5:2012) Plastiques - Dt

    6、ermination de la masse molculaire moyenne et de la distribution des masses molculaires de polymres par chromatographie dexclusion strique - Partie 5: Mthode utilisant la dtection par diffusion lumineuse (ISO 16014-5:2012) Kunststoffe - Bestimmung der durchschnittlichen Molmasse und der Molmassenvert

    7、eilung von Polymeren mittels Gelpermeationschromatographie - Teil 5: Lichtstreudetektionsverfahren (ISO 16014-5:2012) This European Standard was approved by CEN on 30 June 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this E

    8、uropean Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official vers

    9、ions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria,

    10、 Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, S

    11、witzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Member

    12、s. Ref. No. EN ISO 16014-5:2012: EBS EN ISO 16014-5:2012EN ISO 16014-5:2012 (E) 3 Foreword This document (EN ISO 16014-5:2012) has been prepared by Technical Committee ISO/TC 61 “Plastics“ in collaboration with Technical Committee CEN/TC 139 “Paints and varnishes” the secretariat of which is held by

    13、 DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2013, and conflicting national standards shall be withdrawn at the latest by January 2013. Attention is drawn to the possibility that

    14、some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to i

    15、mplement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Roma

    16、nia, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Endorsement notice The text of ISO 16014-5:2012 has been approved by CEN as a EN ISO 16014-5:2012 without any modification. BS EN ISO 16014-5:2012ISO 16014-5:2012(E) ISO 2012 All rights reserved iiiContents PageForeword . v1

    17、 Scope 12 Normative references . 13 Terms and definitions . 14 Symbols . 25 Principle . 25.1 SEC 25.2 Light-scattering SEC 26 Reagents 26.1 Eluent 26.2 Reagent for column evaluation . 36.3 Calibration standards . 36.4 Reagent for flow rate marker 36.5 Additives 37 Apparatus 37.1 General . 37.2 Eluen

    18、t reservoir . 47.3 Pumping system 47.4 Injector . 47.5 Columns . 47.6 Detector 57.7 Tubing . 57.8 Temperature control . 57.9 Recorder and plotter . 57.10 Data-processing system 57.11 Other components 58 Procedure 58.1 Preparation of calibration solutions . 58.2 Preparation of a solution for determin

    19、ing the L-point . 58.3 Preparation of sample solutions . 58.4 Preparation of solutions for column performance evaluation 68.5 Setting up the apparatus . 68.6 Operating parameters 68.7 Number of determinations 69 Calibration . 69.1 Calibration of concentration-sensitive detector and light-scattering

    20、detector 69.2 Determination of delay volume 89.3 Normalization of detector sensitivity . 89.4 Determination of refractive index increment . 810 Data acquisition and processing 810.1 Data acquisition . 810.2 Evaluation of data and correction of chromatograms 810.3 Data processing . 911 Expression of

    21、results .1011.1 Calibration curve .1011.2 Calculation of average molecular mass 1211.3 Differential molecular mass distribution curve .1211.4 Cumulative molecular mass distribution curve 1212 Precision 1313 Test report .13BS EN ISO 16014-5:2012ISO 16014-5:2012(E)iv ISO 2012 All rights reserved13.1 G

    22、eneral .1313.2 Apparatus and measurement parameters 1313.3 Calibration of the system 1313.4 Calibration curve .1413.5 Results .14Annex A (informative) Round-robin test .15Annex B (informative) Information on light scattering .17Annex C (informative) Calibration curve in low molecular mass range 21Bi

    23、bliography .23BS EN ISO 16014-5:2012ISO 16014-5:2012(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees.

    24、Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the Internat

    25、ional Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.The main task of technical committees is to prepare International Standards. Draft International Standar

    26、ds adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.Attention is drawn to the possibility that some of the elements of this document may be the subject o

    27、f patent rights. ISO shall not be held responsible for identifying any or all such patent rights.ISO 16014-5 was prepared by Technical Committee ISO/TC 61, Plastics, Subcommittee SC 5, Physical-chemical properties.ISO 16014 consists of the following parts, under the general title Plastics Determinat

    28、ion of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography: Part 1: General principles Part 2: Universal calibration method Part 3: Low-temperature method Part 4: High-temperature method Part 5: Method using light-scattering detection ISO 2012 All r

    29、ights reserved vBS EN ISO 16014-5:2012BS EN ISO 16014-5:2012Plastics Determination of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography Part 5: Method using light-scattering detection1 ScopeThis part of ISO 16014 specifies a general method for det

    30、ermining the average molecular mass and the molecular mass distribution of polymers using SEC-LS, i.e. size-exclusion chromatography coupled with light-scattering detection. The average molecular mass and the molecular mass distribution are calculated from molecular mass data and mass concentrations

    31、 determined continuously with elution time. The molecular mass at each elution time is determined absolutely by combining a light-scattering detector with a concentration-sensitive detector. Therefore, SEC-LS is classified as an absolute method.For the applicability of the method, see ISO 16014-1:20

    32、12, Clause A.1.2 Normative referencesThe following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.ISO 472, Plas

    33、tics VocabularyISO 16014-1:2012, Plastics Determination of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography Part 1: General principlesISO 16014-2, Plastics Determination of average molecular mass and molecular mass distribution of polymers using

    34、size-exclusion chromatography Part 2: Universal calibration methodISO 16014-3:2012, Plastics Determination of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography Part 3: Low-temperature methodISO 16014-4:2012, Plastics Determination of average molec

    35、ular mass and molecular mass distribution of polymers using size-exclusion chromatography Part 4: High-temperature method3 Terms and definitionsFor the purposes of this document, the terms and definitions given in ISO 472 and ISO 16014-1 and the following apply.3.1light-scattering detectionLS detect

    36、iona technique for determining the mass or size of polymer molecules in solution by measuring the light scattered by the polymer moleculesINTERNATIONAL STANDARD ISO 16014-5:2012(E) ISO 2012 All rights reserved 1BS EN ISO 16014-5:2012ISO 16014-5:2012(E)3.2refractive index incrementdn/dcrate of change

    37、 of the refractive index n of a polymer solution as a function of the mass concentration cNOTE 1 It is also called the “specific refractive index increment” in the literature.NOTE 2 The limiting value of dn/dc at zero concentration is commonly used in light scattering.3.3L-pointmeasured data point o

    38、f a low molecular mass compound on the graph of molecular mass vs. elution time used for justification of the polynominal fit of the calibration curve and/or construction of the calibration curve.NOTE In the lower molecular mass region, the LS signal is too low to calculate molecular mass. Therefore

    39、 the measurement of the L-point is needed for justification or construction of the molecular mass calibration curve for the whole range of molecular mass. The L-point is determined by measuring an oligomer of the polymer or an organic compound with a similar chemical structure to the oligomer.4 Symb

    40、olsRgradius of gyration of a polymer molecule in solution nmA2second virial coefficient for a polymer molecule in solution cm3molg2c mass concentration of polymer in solution gcm3dn/dc refractive index increment cmg1Hiexcess signal intensity of a concentration detector at the ith elution time ILS,ie

    41、xcess signal intensity of scattered light at the ith elution time Vevolume eluted during data acquisition time (interval) cm35 Principle5.1 SECFor a discussion of size-exclusion chromatography in general, see ISO 16014-1:2012, Clause 4.5.2 Light-scattering SECIn SEC-LS, polymer molecules eluted from

    42、 the SEC columns are irradiated by a beam of monochromatic visible light. The light scattered by the molecules is continuously detected by a light-scattering detector. Since the eluate is a dilute polymer solution, the intensity of the scattered light is approximately proportional to the product of

    43、the molecular mass and the mass concentration of the polymer molecules. The scattered-light intensity divided by the concentration therefore gives the molecular mass at a particular elution time. The values of the molecular mass and the mass concentration or mass fraction at each elution time are us

    44、ed to calculate the molecular mass distribution and the average molecular mass of the polymer.6 Reagents6.1 EluentFor a general discussion of eluents, see ISO 16014-1:2012, 5.1.For examples of eluents used for SEC measurements at temperatures below and above 60 C, see Annex B of ISO 16014-3:2012 and

    45、 Annex B of ISO 16014-4:2012, respectively.2 ISO 2012 All rights reservedBS EN ISO 16014-5:2012ISO 16014-5:2012(E)6.2 Reagent for column evaluationFor examples of low molecular mass compounds used for column evaluation, see ISO 16014-3:2012, 5.2, for measurements at temperatures below 60 C and ISO 1

    46、6014-4:2012, 5.2, for those above 60 C.6.3 Calibration standardsSince the Rayleigh ratios of toluene and benzene are well-known, these solvents are recommended for determining the calibration constant of the light-scattering detector (see Annex B, Clause B.2).Aqueous solutions of potassium chloride

    47、(KCl) or sodium chloride (NaCl) are used for determining the calibration constant of a refractive index detector. The concentration dependence of the differential refractive index of the solutions is used to calculate the constant.A low molecular mass, monodisperse polymer is used to determine the d

    48、elay volume between the light-scattering and concentration-sensitive detectors. This polymer may also be used to calibrate the angular dependence of the detector sensitivity of a multiple-angle light-scattering detector. The radius of gyration Rgof the polymer molecule used to calibrate the detector

    49、 sensitivity, should preferably be less than 10 nm. A radius of gyration less than 5 nm is desirable. Other compounds with a well-known Rgvalue may also be used.Polymer reference materials are used for molecular mass calibration ranges from 20 000 to 50 000.Low molecular mass organic compounds or oligomers of the polymer in the sample under investigation are used for determining the “L-point”.6.4 Reagent for flow rate markerSee ISO 16014-1:2012, 5.4.For examples of compounds suitable for use as a flow rate marker, see


    注意事项

    本文(EN ISO 16014-5-2012 en Plastics - Determination of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography - Part 5 Method using ligh.pdf)为本站会员(cleanass300)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开