1、BRITISH STANDARDBS EN 62244:2011Radiation protection instrumentation Installed radiation monitors for the detection of radioactive and special nuclear materials at national bordersICS 13.280g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g
2、51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58National forewordThis British Standard is the UK implementation of EN 6224:2011. It is identical to IEC 62244:2006. It supersedes BS IEC 62244:2006, which is withdrawn.The CENELEC common modifications have been
3、 implemented at the appropriate places in the text. The start and finish of each common modification is indicated in the text by .The UK participation in its preparation was entrusted to Technical Committee NCE/2, Radiation protection and measurement.A list of organizations represented on this commi
4、ttee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.BS EN 62244:2011This British St
5、andard was published under the authority of the Standards Policy and Strategy Committee on 31 July 2006 BSI 2011Amendments/corrigenda issued since publicationDate Comments 30 Septmeber 2011 This corrigendum renumbers BS IEC 62244:2006 as BS EN 62244:2011ISBN 978 0 580 61121 6EUROPEAN STANDARD EN 622
6、44 NORME EUROPENNE EUROPISCHE NORM July 2011 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC - All rights of exploitati
7、on in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 62244:2011 E ICS 13.280 English version Radiation protection instrumentation - Installed radiation monitors for the detection of radioactive and special nuclear materials at national borders (IEC 62244:2006, modified
8、) Instrumentation pour la radioprotection - Moniteurs de rayonnement installs pour la dtection des matriaux nuclaires radioactifs et spciaux aux frontires nationales (CEI 62244:2006, modifie) Strahlenschutz-Messgerte - Fest installierte Strahlungsmonitore fr den Nachweis von radioaktiven Stoffen und
9、 spaltbarem Nuklearmaterial an Staatsgrenzen (IEC 62244:2006, modifiziert) This European Standard was approved by CENELEC on 2011-06-27. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a nati
10、onal standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version i
11、n any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cypru
12、s, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of the Inter
13、national Standard IEC 62244:2006, prepared by SC 45B, “Radiation protection instrumentation”, of IEC TC 45, “Nuclear instrumentation”, together with the common modifications prepared by the Technical Committee CENELEC TC 45B, Radiation protection instrumentation, was submitted to the CENELEC formal
14、vote and was approved by CENELEC as EN 62244 on 2011-06-27. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixe
15、d: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2012-06-27 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2014-06-27 Annex ZA has been added by CENELEC. Sub
16、clauses which are additional to those in IEC 62244 are prefixed “Z”. _ Endorsement notice The text of the International Standard IEC 62244:2006 was approved by CENELEC as a European Standard with agreed common modifications. BS EN 62244:2011EN 62244:2011 (E) 2 Annex ZA (normative) Normative referenc
17、es to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (incl
18、uding any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60038 - IEC standard voltages EN 600381- IEC 60050-393 - International Electrotechnology Vocabulary -
19、 Part 393: Nuclear instrumentation - Physical phenomena and basic concepts - - IEC 60050-394 + A1 + A2 1995 1996 2000 International Electrotechnical Vocabulary - Chapter 394: Nuclear instrumentation: Instruments - - - - - - IEC 60068-2-18 - Environmental testing - Part 2-18: Tests - Tests R and guid
20、ance: WaterEN 60068-2-18 - IEC 60068-2-27 Environmental testing - Part 2-27: Tests - Test Ea and guidance: ShockEN 60068-2-27 - IEC 60068-2-75 - Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests EN 60068-2-75 - IEC 60359 - Electrical and electronic measurement equipment - Expression o
21、f performance EN 60359 - IEC 61000-4-2 - Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test EN 61000-4-2 - IEC 61000-4-3 - Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-freq
22、uency, electromagnetic field immunity test EN 61000-4-3 - IEC 61000-4-4 - Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test EN 61000-4-4 - IEC 61000-4-5 - Electromagnetic compatibility (EMC) - Part 4-5: Testing and meas
23、urement techniques - Surge immunity test EN 61000-4-5 - IEC 61000-4-6 - Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields EN 61000-4-6 - IEC 61000-4-12 - Electromagnetic compatibility (EMC) - Par
24、t 4-12: Testing and measurement techniques - Ring wave immunity test EN 61000-4-12 - IEC 61187 - Electrical and electronic measuring equipment -Documentation EN 61187 - 1At draft stage. BS EN 62244:2011EN 62244:2011 (E) 3 CONTENTS 1 Scope and object .652 Normative references .6553 Terms and definiti
25、ons .764 General characteristics.984.1 Overview .984.2 Pedestrian.984.3 Road vehicles (includes road transported containers) 1094.4 Rail vehicles (includes rail transported containers) 1094.5 Conveyor. 1094.6 Configuration. 10 104.7 Indication features.11104.8 Speed control11105 General test procedu
26、res .1110105.1 Nature of tests.11105.2 Reference conditions and standard test conditions 12 5.3 Tests performed under standard test conditions 12 5.4 Tests performed with variation of influence quantities12 5.5 Statistical fluctuations .12 5.6 Alarm probability for gamma and neutron radiation12 5.7
27、Reference radiation.12 6 Radiation characteristics 13 6.1 False alarm test 13 6.2 Background effects13 6.3 Gamma radiation detection14 6.4 Neutron radiation detection .146.5 Overload characteristics15 7 Electrical characteristics.15 7.1 Mains operation.157.2 Occupancy sensor.16 8 Electromagnetic com
28、patibility .16 8.1 External magnetic fields 16 8.2 Radiated electromagnetic fields.16 8.3 Conducted disturbances induced by bursts and radio frequencies .17 8.4 Surges and oscillatory waves 17 8.5 Electrostatic discharge 18 9 Mechanical characteristics199.1 Areas of application.19 9.2 Mechanical sho
29、cks 19 9.3 Vibration test.199.4 Microphonics/impact20 BS EN 62244:2011EN 62244:2011 (E) 4 10 Environmental characteristics.20 10.1 Ambient temperature .20 10.2 Relative humidity.21 10.3 Sealing21 11 Documentation .22 11.1 Type test report.22 11.2 Certificate .22 11.3 Operation and maintenance manual
30、 22 Annex A (informative) Standardized special nuclear materials test sources for type testing of installed radiation monitors at national borders26 Figure 1 Example of a two-sided system 25 Table 1 Reference conditions and standard test conditions23 Table 2 Tests performed under standard test condi
31、tions 23 Table 3 Tests performed with variations of influence quantities24 Table A.1 Minimum SNM test sources27 BS EN 62244:2011EN 62244:2011 (E) 5 RADIATION PROTECTION INSTRUMENTATION INSTALLED RADIATION MONITORS FOR THE DETECTION OF RADIOACTIVE AND SPECIAL NUCLEAR MATERIALS AT NATIONAL BORDERS 1 S
32、cope and object The scope of this International Standard is to define the performance of installed monitors used for the detection of gamma and neutron radiation emitters contained in objects/ containers or vehicles, general characteristics, mechanical characteristics, environmental requirements, te
33、st procedures and documentation. This standard is applicable to installed monitors designed to detect special nuclear and other radioactive materials by their emitted gamma and/or neutron radiation. They are used to monitor vehicles, cargo containers, people, or packages and are typically located at
34、 national and international borders, but may be used at any location where there is a need for this type of monitoring. This standard does not apply to hand-held monitors. Information regarding the detection of special nuclear material (SNM) is contained in Annex A. This standard provides the purcha
35、ser with information that may be used to determine the performance of the monitor in detecting the presence of radioactive sources. This standard does not provide the data needed to determine the performance of the monitor in measuring the quantity of the radioactive material. In this standard, the
36、term radioactive material includes both special nuclear and radioactive material unless otherwise specifically noted. The radioactive material may be transported by vehicle, carried by person, or concealed in a cargo container or in a package moved by conveyor belt, such as international mail parcel
37、s. Conformance with the requirements of this standard does not guarantee that a radioactive source will always be discovered. The selection of the location and the configuration of the monitoring system on each site needs to be optimised to achieve the best performance, however, this is outside the
38、scope of this standard. 2 Normative references The following referenced documents are relevant to the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 6003
39、8, IEC standard voltages IEC 60050-393, International Electrotechnical Vocabulary (IEV) Part 393: Nuclear instrumentation Physical phenomena and basic concepts BS EN 62244:2011EN 62244:2011 (E) 6 IEC 60050-394:1995, International Electrotechnical Vocabulary (IEV) Chapter 394: Nuclear instrumentation
40、: Instruments Amendment 1 (1996) Amendment 2 (2000) IEC 60068-2-18, Environmental testing Part 2-18: Tests Test R and guidance: Water IEC 60068-2-27, Environmental testing Part 2: Tests Test Ea and guidance: Shock IEC 60068-2-75, Environmental testing Part 2-75: Tests Test Eh: Hammer tests IEC 60359
41、, Electrical and electronic measurement equipment Expression of performance IEC 61000-4-2, Electromagnetic compatibility (EMC) Part 4-2: Testing and measurement techniques Electrostatic discharge immunity test IEC 61000-4-3, Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement techn
42、iques Radiated, radio-frequency, electromagnetic field immunity test IEC 61000-4-4, Electromagnetic compatibility (EMC) Part 4-4: Testing and measurement techniques Electrical fast transient/burst immunity test IEC 61000-4-5, Electromagnetic compatibility (EMC) Part 4-5: Testing and measurement tech
43、niques Surge immunity test. IEC 61000-4-6, Electromagnetic compatibility (EMC) Part 4-6: Testing and measurement techniques Immunity to conducted disturbances induced by radio-frequency fields IEC 61000-4-12, Electromagnetic compatibility (EMC) Part 4-12: Oscillatory waves immunity test IEC 61187, E
44、lectrical and electronic equipment Documentation 3 Terms and definitions For the purposes of this document, the following terms and definitions, as well as those given in IEC 60050-393, IEC 60050-394 and IEC 60359, apply. 3.1 alarm assembly 3.2 detection assembly component that provides audio or vis
45、ual signals, or both, when an alarm level is exceeded or a malfunction occurs. component of the installed radiation monitor system that contains the detector(s) and associated electronic devices. BS EN 62244:2011EN 62244:2011 (E) 7 3.3 detection zone location where radiation emitted by an object or
46、person being monitored may be detected by the detection assembly(s). For two-sided monitors, the detection zone is located between opposing detection assemblies; for single-sided monitors, the detection zone is adjacent to the detection assembly surface 3.4 radioactive material both special nuclear
47、and radioactive material, unless otherwise specifically noted 3.5 reference point of an assembly physical mark on a piece of equipment or assembly to be used in order to position it at a point where the conventionally true value of the quantity to be measured is known NOTE For this standard, the phy
48、sical mark may be used to identify where a source is positioned. 3.6 reference point of the detection zone 3.7 units units of the International System (SI) 3.8 Test nomenclature 3.8.1 qualification tests tests performed on a representative sample of equipment to verify the adequacy of the design and
49、 that the equipment meets the specifications agreed upon between manufacturer and user under normal, operational conditions and anticipated operation occurrences NOTE Qualification tests are performed in order to verify that the requirements of a specification are fulfilled. 3.8.2 type test conformity test made of one or more items representative of the production IEV 394-20-28, modified 3.8.3 routine test test to which every device is subjected by the manufacturer or by the user