欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    EN 16475-3-2016 en Chimneys - Accessories - Part 3 Draught regulators standstill opening devices and combined secondary air devices - Requirements and test methods《烟囱-附件-第3部分 排烟调节器.pdf

    • 资源ID:715867       资源大小:2.07MB        全文页数:44页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    EN 16475-3-2016 en Chimneys - Accessories - Part 3 Draught regulators standstill opening devices and combined secondary air devices - Requirements and test methods《烟囱-附件-第3部分 排烟调节器.pdf

    1、BS EN 16475-3:2016Chimneys AccessoriesPart 3: Draught regulators, standstillopening devices and combined secondaryair devices Requirements and testmethodsBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 16475-3:2016 BRITISH STANDARDNational forewordThis British

    2、Standard is the UK implementation of EN 16475-3:2016.The UK participation in its preparation was entrusted to TechnicalCommittee B/506/1, Chimneys general requirements.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport t

    3、o include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2016 .Published by BSI Standards Limited 2016ISBN 978 0 580 80846 3ICS 91.060.40Compliance with a British Standard cannot confer immunity fromlegal obligations.Thi

    4、s British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 July 2016.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS EN 16475-3:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 16475-3 April 2016 ICS 91.060.40 English

    5、 Version Chimneys - Accessories - Part 3: Draught regulators, standstill opening devices and combined secondary air devices - Requirements and test methods Conduits de fume - Accessoires - Partie 3: Rgulateurs de tirage, dispositifs douverture pour priode darrt et dispositifs combins dair secondaire

    6、 - Exigences et mthodes dessai Abgasanlagen - Zubehrteile - Teil 3: Selbstttig arbeitende, zwangsgesteuerte und kombinierte Nebenluftvorrichtungen - Anforderungen und Prfmethoden This European Standard was approved by CEN on 27 November 2015. CEN members are bound to comply with the CEN/CENELEC Inte

    7、rnal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any

    8、 CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official ve

    9、rsions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway

    10、, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey andUnited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CEN All rights of exploita

    11、tion in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16475-3:2016 EBS EN 16475-3:2016EN 16475-3:2016 (E) 2 Contents Page European foreword . 5 Introduction 6 1 Scope 7 2 Normative references 7 3 Terms and definitions . 7 4 Product characteristics . 8 4.1 General

    12、 8 4.2 Dimensions and tolerances . 8 4.3 Mechanical resistance and stability . 8 4.4 Thermal performance . 8 4.4.1 Reaction to fire . 8 4.4.2 Fire resistance (internal to external) 8 4.5 Hygiene, health and environment . 9 4.5.1 Gas tightness . 9 4.5.2 Condensate resistance . 9 4.5.3 Corrosion resis

    13、tance 9 4.5.4 Dangerous substances . 9 4.6 Additional criteria for chimney operation. 9 4.6.1 Determination of the draught regulator group 9 4.6.2 Adjustability and function of the draught regulator . 10 4.6.3 Durability of the standstill opening device . 11 4.7 Electrical requirements . 11 4.7.1 Mo

    14、tor 11 4.7.2 Limit switches 11 5 Testing, assessment and sampling methods 11 5.1 Thermal performance 11 5.1.1 General . 11 5.1.2 Test Assembly 12 5.1.3 Test procedure 13 5.1.4 Standstill opening device durability test . 14 5.2 Gas tightness 14 5.2.1 Test assembly 14 5.2.2 Test Procedure 15 5.2.3 Tes

    15、t results . 15 5.3 Additional criteria for chimney operation 15 5.3.1 Adjustability of the draught regulator . 15 5.3.2 Draught regulator group test . 16 6 Assessment and verification of constancy of performance (AVCP) . 16 6.1 General . 16 6.2 Type testing 16 6.2.1 General . 16 6.2.2 Test samples,

    16、testing and compliance criteria 17 6.2.3 Test reports 18 6.2.4 Shared other party results 18 BS EN 16475-3:2016EN 16475-3:2016 (E) 3 6.2.5 Cascading determination of the product type results . 19 6.3 Factory production control (FPC) . 20 6.3.1 General . 20 6.3.2 Requirements . 20 6.3.3 Product speci

    17、fic requirements 23 6.3.4 Initial inspection of factory and of FPC . 23 6.3.5 Continuous surveillance of FPC . 24 6.3.6 Procedure for modifications . 24 7 Manufacturers declaration for type test . 24 8 Product information 25 8.1 Manufacturers instructions . 25 8.2 Minimum information to be included

    18、in the manufacturers instructions . 25 9 Classification and designation . 25 9.1 General . 25 9.2 Temperature classes and test temperature 26 9.3 Corrosion resistance 26 9.4 Soot fire resistance and distance to combustible material . 26 9.5 Draught regulator groups and whether it is a standstill ope

    19、ning device . 26 10 Marking, labelling and packaging . 26 10.1 Draught regulator and standstill opening device . 26 10.2 Packaging . 27 Annex A (normative) Choice of sizes for type test and sampling . 28 A.1 Thermal testing . 28 A.2 Gas tightness . 28 A.3 Condensate resistance 28 A.4 Determination o

    20、f the group 28 A.5 Adjustability . 28 A.6 Durability of standstill opening device . 28 A.7 Samples 28 A.8 Factory production control system 28 A.9 Further type testing . 28 Annex B (informative) Sampling for factory productions control . 29 B.1 Sampling plans . 29 B.1.1 General . 29 B.1.2 Acceptable

    21、 quality level (AQL) . 29 B.1.3 The inspection level . 29 B.1.4 Normal, tightened or reduce inspection 29 B.1.5 Single, double, multiple or sequential sampling . 29 B.1.6 Batch quantity 29 B.2 Inspection levels and procedures . 29 B.2.1 Incoming material 29 BS EN 16475-3:2016EN 16475-3:2016 (E) 4 B.

    22、2.2 In-process inspection . 30 B.2.3 Finished goods checks 30 Annex C (normative) Factory production control . 31 C.1 Introduction . 31 C.2 Materials, including coatings . 31 C.3 Seals and sealants 31 C.4 Manufacturing checks 31 C.4.1 Dimensions . 31 C.4.2 Other checks 31 Annex D (informative) Recom

    23、mended range of application . 32 D.1 Tables for the selection of the draught regulator group Height against diameter 32 Annex E (informative) Examples of products . 34 E.1 Without standstill opening device . 34 Annex ZA (informative) Relationship of this European Standard with Regulation (EU) No.305

    24、/2011 36 ZA.1 Scope and relevant characteristics 36 ZA.2 System of Assessment and Verification of Constancy of Performance (AVCP) 37 ZA.3 Assignment of AVCP tasks . 37 Bibliography . 40 BS EN 16475-3:2016EN 16475-3:2016 (E) 5 European foreword This document (EN 16475-3:2016) has been prepared by Tec

    25、hnical Committee CEN/TC 166 “Chimneys”, the secretariat of which is held by ASI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2016, and conflicting national standards shall be withdrawn

    26、 at the latest by January 2018. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given

    27、to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Regulation, see informative Annex ZA, which is an integral part of this document. According to the CEN/CENELEC Internal Regulations, the nationa

    28、l standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithua

    29、nia, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 16475-3:2016EN 16475-3:2016 (E) 6 Introduction This standard forms a part of the series of standards for chimney accessories: Part 1: Silencers

    30、 Part 2: Chimney fans Part 3: Draught regulators, standstill opening devices and combined secondary air devices (this part) Part 4: Flue dampers Part 5: Explosion/implosion relief devices Part 6: Access components Part 7: Rain caps Independent draught regulators are for the purpose of reducing negat

    31、ive pressure that is too large in the chimney, which can result through the use of commercially available cross-section dimensions, despite being designed e.g. according to EN 13384-1:2015, Calculation method for chimneys serving single appliance. They serve to increase the flue gas speed and the ve

    32、ntilation of the chimney, for the purpose of drying out (see explanations). Standstill opening devices interlocked with the combustion system are exclusively for the purpose of ventilating the chimney during standby. BS EN 16475-3:2016EN 16475-3:2016 (E) 7 1 Scope This European Standard specifies th

    33、e requirements and test methods for draught regulators, standstill opening devices and combined secondary air devices that are used as components, carrying flue gases, in order to limit the draught in chimneys and provide secondary air to the chimney. Draught regulators, standstill opening devices a

    34、nd combined secondary air devices for positive pressure chimneys are not covered by this standard. It also specifies the requirements for marking, manufacturers instruction, product information and attestation and verification of constancy of performance (AVCP). 2 Normative references The following

    35、documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1443, Chimneys Gen

    36、eral requirements EN 10088-1, Stainless steels Part 1: List of stainless steels EN 10346, Continuously hot-dip coated steel flat products for cold forming Technical delivery conditions EN 13216-1, Chimneys Test methods for system chimneys Part 1: General test methods EN 60730-2-14, Automatic electri

    37、cal controls for household and similar use Part 2-14: Particular requirements for electric actuators (IEC 60730-2-14) EN 61058-1, Switches for appliances Part 1: General requirements (IEC 61058-1) 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 1443,

    38、and the following apply. 3.1 draught regulator device with a hinged flap in a flue opening to allow entry of secondary air into the flue to regulate the draught 3.2 standstill opening device device which is opened motorised to allow air to enter the flue during the standstill period of the heating a

    39、ppliance 3.3 combined secondary air device combination of a draught regulator and standstill opening device BS EN 16475-3:2016EN 16475-3:2016 (E) 8 3.4 sootfire safe accessory (As) accessory that may not perform its intended function during and after a sootfire but does not prevent the safe operatio

    40、n or change the designation “G” of the chimney or connecting flue pipe Note 1 to entry: “As” can only be used for accessories and not for chimneys, flue liners and connecting flue pipes. Note 2 to entry: Measures to be taken after the event of a sootfire are to be found in the relevant product stand

    41、ard. 4 Product characteristics 4.1 General The draught regulator, and if appropriate the standstill opening device, housing and flap in contact with combustion products shall have a material with 0,6 mm minimum thickness, and a specification for steel according to EN 10088-1 of 1.4301, and 1.4404, a

    42、nd 1.0306 according to EN 10346 for any corrosion class for dry applications, and for wet applications, only for corrosion class 1 and 2, a steel according to EN 10088-1 of 1.4404 or higher. The draught regulator and standstill opening devices shall fulfil the following requirements, if appropriate.

    43、 The combined secondary air devices shall fulfil the requirements of both, if appropriate. 4.2 Dimensions and tolerances The manufacturer is free to choose dimensions and tolerances for the manufacture of draught regulators and if appropriate standstill opening devices. 4.3 Mechanical resistance and

    44、 stability The draught regulator, and standstill opening device, shall be able to move freely before and after the thermal tests except for a product designated As after a soot fire test. 4.4 Thermal performance 4.4.1 Reaction to fire As the fire reaction is not relevant for draught regulators and/o

    45、r standstill opening devices, no declaration is necessary. 4.4.2 Fire resistance (internal to external) 4.4.2.1 General The manufacturer shall declare the minimum distance of the draught regulator, and if appropriate standstill opening device, to combustible material and the requirement of 4.4.2.2 a

    46、nd if appropriate 4.4.2.3 shall be met at the distance declared by the manufacturer. For a temperature designation up to T450, a declaration of at least 400 mm for the distance to combustible material is deemed to satisfy this requirement without testing. 4.4.2.2 Heat stress The draught regulator, a

    47、nd if appropriate standstill opening device, shall be tested in accordance with 5.1.3.2 and the requirements of 4.3 and 4.5.1 shall be met, and one of the flow rates of the group determination of 4.6.1, at the lowest declared setting, is within 10 % of the original value determined before thermal ex

    48、posure. BS EN 16475-3:2016EN 16475-3:2016 (E) 9 4.4.2.3 Sootfire The draught regulator, and if appropriate the standstill opening device, designated sootfire resistant shall be tested in accordance with 5.1.3.3 and the requirements of 4.3 and 4.5.1 shall be met, and one of the flow rates of the grou

    49、p determination of 4.6.1, at the lowest declared setting, is within 10 % of the original value determined before thermal exposure. If the product satisfies all criteria it may be designated G. If it only satisfies the criteria of 4.5.1 it may be designated As. Otherwise it may only be designated O. 4.5 Hygiene, health and environment 4.5.1 Gas tightness When a draught regulator, and if appropriate standstill opening device, is tested according to the test methods described in 5.1, the individual values of leakage rate shall not be v


    注意事项

    本文(EN 16475-3-2016 en Chimneys - Accessories - Part 3 Draught regulators standstill opening devices and combined secondary air devices - Requirements and test methods《烟囱-附件-第3部分 排烟调节器.pdf)为本站会员(explodesoak291)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开