    EN 15269-7-2009 en Extended application of test results for fire resistance and or smoke control for door shutter and openable window assemblies including their elements of buildin.pdf

    • 资源ID:714921       资源大小:2.50MB        全文页数:82页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    EN 15269-7-2009 en Extended application of test results for fire resistance and or smoke control for door shutter and openable window assemblies including their elements of buildin.pdf

    1、BS EN 15269-7:2009ICS 13.220.50; 91.060.50NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDExtended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardwar

    2、e Part 7: Fire resistance for steel sliding doorsets This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 November 2009 BSI 2009ISBN 978 0 580 56359 1Amendments/corrigenda issued since publicationDate CommentsBS EN 15269-7:2009National foreword

    3、This British Standard is the UK implementation of EN 15269-7:2009.The UK participation in its preparation was entrusted to TechnicalCommittee FSH/22/5, Test procedures for doors.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not

    4、 purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.BS EN 15269-7:2009EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15269-7 November 2009 ICS 13.220.50;

    5、 91.060.50 English Version Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 7: Fire resistance for steel sliding doorsets Application largie des rsultats dessai en mati

    6、re de rsistance au feu et dtanchit la fume des blocs-portes, blocs-fermetures et ouvrants de fentres, y compris les lments intgrs de quincaillerie de btiment - Partie 7: Rsistance au feu des blocs-portes coulissants en acierErweiterter Anwendungsbereich von Prfergebnissen zur Feuerwiderstandsfhigkei

    7、t und/oder Rauchdichtigkeit von Tren, Toren und Fenstern einschlielich ihrer Baubeschlge - Teil 7: Feuerwiderstandsfhigkeit von Schiebetoren aus Stahl This European Standard was approved by CEN on 22 September 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stip

    8、ulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard

    9、 exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standa

    10、rds bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United King

    11、dom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15269-7:2009: EBS E

    12、N 15269-7:2009EN 15269-7:2009 (E) 2 Contents Page Foreword . 3Introduction . 41 Scope 52 Normative references 53 Terms and definitions . 64 Determination of the field of extended application 74.1 General . 74.2 Procedure for evaluation 74.3 Procedure for maximum field of extended application . 84.4

    13、Interpretation of test results . 85 Extended application report . 86 Classification report 9Annex A (normative) Construction parameter variations 10Figures relating to Annex A . 64BS EN 15269-7:2009EN 15269-7:2009 (E) 3 Foreword This document (EN 15269-7:2009) has been prepared by Technical Committe

    14、e CEN/TC 127 “Fire safety in buildings”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2010, and conflicting national standards shall be withdrawn at

    15、 the latest by May 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN

    16、by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgi

    17、um, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 15269-7:2009E

    18、N 15269-7:2009 (E) 4 Introduction This European Standard is one of a series of standards listed below and intended to be used for the purpose of producing an extended application report based on the evaluation of one or more fire resistance and/or smoke control tests. These standards may also be use

    19、d to identify the best selection of test specimens required to cover a wide range of product variations. The EN 15269 series currently consists of: prEN 15269, Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including th

    20、eir elements of building hardware Part 1: General requirements Part 2: Fire resistance of hinged and pivoted steel doorsets Part 3: Fire resistance of hinged and pivoted timber doorsets and openable timber framed windows Part 5: Fire resistance of hinged and pivoted metal framed glazed doorsets and

    21、openable windows Part 6: Fire resistance of sliding timber doorsets Part 10: Fire resistance of steel rolling shutters Part 11: Fire resistance of operable fabric curtains as well as EN 15269, Extended application of test results for fire resistance and/or smoke control for door, shutter and openabl

    22、e window assemblies, including their elements of building hardware Part 7: Fire resistance for steel sliding doorsets Part 20: Smoke control for hinged and pivoted steel, timber and metal framed glazed doorsets Before there can be any consideration for extended application the doorset should have be

    23、en tested in accordance with EN 1634-1 to achieve a test result which could generate a classification in accordance with EN 13501-2 at least equal to the classification subsequently required from extended application considerations. A review of the doorset construction parameters can indicate that o

    24、ne or more characteristics may be improved by a particular parameter variation. All evaluations should be made on the basis of retaining the fire resistance classifications obtainable from testing to EN 1634-1, including those lower than the test duration. However, this should never lead to an incre

    25、ased classification for any specific fire or smoke performance parameter beyond that achieved during any one test unless specifically identified in the relevant Construction Parameter Variation tables within this series of standards. The effect on the durability of self closing of the doorsets follo

    26、wing an extended application process is not addressed in this series of standards. BS EN 15269-7:2009EN 15269-7:2009 (E) 5 1 Scope This European Standard, which should be read in conjunction with prEN 15269-1, covers the following types of steel based doorsets: horizontally sliding doorsets (single

    27、and double), telescopic doorsets (single and double) and single vertically sliding doorsets. This document prescribes the methodology for extending the application of test results obtained from test(s) conducted in accordance with EN 1634-1. Subject to the completion of the appropriate test or tests

    28、 selected from those identified in Clause 4 the extended application may cover all or some of the following non-exhaustive list: integrity only (E), radiation (EW) or insulated (EI1or EI2) classifications; door leaf; wall/ceiling fixed elements (frame/suspension system); glazing for door leaf; items

    29、 of building hardware; decorative finishes; intumescent, smoke, draught or acoustic seals; alternative supporting construction(s). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. F

    30、or undated references, the latest edition of the referenced document (including any amendments) applies. EN 1363-1:1999, Fire resistance tests Part 1: General requirements EN 1634-1:2008, Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of buildin

    31、g hardware Part 1: Fire resistance tests for doors, shutters and openable windows EN 1634-2:2008, Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware Part 2: Fire resistance characterisation test for elements of building hardware

    32、 EN 13501-2:2007, Fire classification of construction products and building elements Part 2: Classification using data from fire resistance tests, excluding ventilation services EN 15254-4:2008, Extended application of results from fire resistance tests Non-loadbearing walls Part 4: Glazed construct

    33、ions prEN 15269-1:2007, Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware Part 1: General requirements BS EN 15269-7:2009EN 15269-7:2009 (E) 6 prEN 15269-2, Extended applicatio

    34、n of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware Part 2: Fire resistance of hinged and pivoted steel doorsets EN ISO 13943:2000, Fire safety Vocabulary (ISO 13943:2000) 3 Terms and definitions F

    35、or the purposes of this document, the terms and definitions given in EN 1363-1:1999, EN ISO 13943:2000, EN 1634-1:2008, EN 1634-2:2008 and prEN 15269-1:2007 together with the following apply. 3.1 full scale test test of a full size doorset in accordance with EN 1634-1 3.2 leaf/element/panel differen

    36、t parts of a doorset as indicated in Figures 1 and 2 below 123Key 1 panel 2 leaf 3 element Figure 1 Double leaf telescopic door BS EN 15269-7:2009EN 15269-7:2009 (E) 7 21Key 1 panel 2 leaf Figure 2 Double leaf sliding door 4 Determination of the field of extended application 4.1 General 4.1.1 Before

    37、 there can be any consideration for extended application the doorset shall have been tested and classified in accordance with EN 1634-1 and EN 13501-2 respectively in order to establish a classification for the doorset. 4.1.2 A review of the doorset construction parameters can indicate that one or m

    38、ore characteristics may be improved by a particular parameter variation. All evaluations shall be made on the basis of retaining the classifications obtainable from testing to EN 1634-1, including those lower than the test duration. However, this shall never lead to an increased classification for a

    39、ny specific parameter beyond that achieved during any one test unless specifically identified in the relevant Construction Parameter Variation tables. 4.1.3 All evaluations shall be made on the basis of retaining the classification obtained from testing to EN 1634-1. 4.1.4 If, by following the ensui

    40、ng procedure, any part of the classification cannot be achieved by extended application rules that part of classification shall be omitted from the subsequent extended application report and classification report. 4.2 Procedure for evaluation 4.2.1 Identify the variations from the original test spec

    41、imen(s) which are required to be covered by an extended application report. 4.2.2 Locate the variations in the appropriate parameter variation by reference to columns (1) and (2) of Table A.1. 4.2.3 Review the type of classification to be retained from column (3) of Table A.1 and establish from the

    42、contents of column (4) of Table A.1 whether any extended application is available without the need for further testing. 4.2.4 Where this is deemed to be possible this can be recorded in the extended application report together with any appropriate restrictions and the stated rules from column (4) in

    43、 Table A.1. 4.2.5 Where the variations required can only be achieved from additional testing according to column (5) in Table A.1, the additional test can be made on a similar specimen type to the original test BS EN 15269-7:2009EN 15269-7:2009 (E) 8 against which the extended application is sought.

    44、 Alternatively, column (5) in Table A.1 identifies an option for alternative testing and relevant test parameters. 4.3 Procedure for maximum field of extended application 4.3.1 It is possible to provide a limited field of extended application from the results of a single test. However, where a manuf

    45、acturer intends to produce a range of doors incorporating single doors and also double doors, with or without glazing, with alternative elements of building hardware, etc., it is recommended that careful consideration is given to the complete range of doorset designs and options in order to minimise

    46、 the testing required before testing commences. 4.3.2 Establish all the parameter variations which are required to be part of the product range. 4.3.3 Select specimen(s) for the first test(s) in the series to ensure that the most important parameter variations for the manufactured products are cover

    47、ed. 4.3.4 Complete the first test or a series of tests and prepare a field of direct application and possibly a classification report from the results of the test(s). 4.3.5 Establish which of the original desired parameter variations have not been covered by the direct application and classification

    48、 report. 4.3.6 Identify these parameter variations in Annex A and establish if any extended application is possible without further testing. 4.3.7 Record this for the extended application report together with any restrictions and rules given in column (5) in Table A.1. 4.3.8 Evaluate which, if any,

    49、of the desired parameter variations have not been covered by the field of direct application or the initial field of extended application derived from 4.3.7 above. 4.3.9 Select the required outstanding parameter variations from column (1) and column (2) of Table A.1 and observe from column (5) of Table A.1 which are the most appropriate weakest specimen options for further testing. 4.3.10 If the complete selection of required parameter variations has not been covered by the t


    注意事项

    本文(EN 15269-7-2009 en Extended application of test results for fire resistance and or smoke control for door shutter and openable window assemblies including their elements of buildin.pdf)为本站会员(rimleave225)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!