1、December 2015 English price group 15No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 91.060.10; 91.120.20!%Ig“238596
2、8www.din.deDIN EN 16703Acoustics Test code for drywall systems of plasterboard with steel studs Airborne sound insulation;English version EN 16703:2015,English translation of DIN EN 16703:2015-12Akustik Prfvorschrift fr Trockenwandsysteme aus Metallstnderwnden mit Gipsplattenbeplankung Messung der L
3、uftschalldmmung;Englische Fassung EN 16703:2015,Englische bersetzung von DIN EN 16703:2015-12Acoustique Code dessai pour systmes de cloisons sches en plaques de pltre avec montants en acier Mesure de laffaiblissement arien;Version anglaise EN 16703:2015,Traduction anglaise de DIN EN 16703:2015-12www
4、.beuth.deDTranslation by DIN-Sprachendienst.In case of doubt, the German-language original shall be considered authoritative.Document comprises 30 pages 11.15 DIN EN 16703:2015-12 2 A comma is used as the decimal marker. National foreword This document (EN 16703:2015) has been prepared by Technical
5、Committee CEN/TC 126 “Acoustic properties of building elements and of buildings” (Secretariat: AFNOR, France). The responsible German body involved in its preparation was DIN-Normenausschuss Materialprfung (DIN Standards Committee Materials Testing), Working Committee NA 062-02-31 AA Schalldmmung un
6、d Schall-absorption, Messung und Bewertung. The DIN Standard corresponding to the International Standard referred to in this document is as follows: ISO 12999-1 DIN EN ISO 12999-1 National Annex NA (informative) Bibliography DIN EN ISO 12999-1, Acoustics Determination and application of measurement
7、uncertainties in building acoustics Part 1: Sound insulation EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 16703 September 2015 ICS 91.060.10; 91.120.20 English Version Acoustics - Test code for drywall systems of plasterboard with steel studs - Airborne sound insulation Acoustique - Code des
8、sai pour systmes de cloisons sches en plaques de pltre avec montants en acier - Mesure de laffaiblissement arien Akustik - Prfvorschrift fr Trockenwandsysteme aus Metallstnderwnden mit Gipsplattenbeplankung - Messung der Luftschalldmmung This European Standard was approved by CEN on 8 August 2015. C
9、EN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on ap
10、plication to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
11、Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, L
12、atvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue M
13、arnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16703:2015 EEN 16703:2015 (E) 2 Contents European foreword 4 Introduction 5 1 Scope . 6 2 Normative references 6 3 Terms and definitions . 6 4 Test code
14、 for drywall systems of plasterboard with steel studs . 7 4.1 Application 7 4.2 Testing Guidelines 7 4.2.1 Test element . 7 4.2.2 Boundary and mounting conditions 7 4.2.3 Test report 8 4.3 Validation of the laboratory with two reference test partitions . 8 4.3.1 Test elements . 8 4.3.2 Acceptance cr
15、iteria 8 4.3.3 Remedial investigation . 10 4.4 Application of uncertainties . 11 Annex A (normative) Reference test partition location in aperture . 12 A.1 General . 12 A.2 Case A “Aperture without niche and one acoustic break” 12 A.3 Case B “Aperture without niche and two acoustic breaks with Ratio
16、 2:1”. 13 A.4 Case C “Aperture with niche and one acoustic break” . 13 Annex B (normative) Reference test partition Type 1 . 14 B.1 Description of Reference test partition Type 1 14 B.1.1 Single Framework, single board layer partition . 14 B.2 Installation procedure of partition Type 1 15 B.2.1 Inst
17、allation of framework with channels and studs 15 B.2.2 Installation of plasterboards 1st side . 16 B.2.3 Installation of insulation in cavity 16 B.2.4 Installation of plasterboards 2nd side 16 B.2.5 Jointing for both sides of the partition 16 Annex C (normative) Reference test partition Type 2 18 C.
18、1 Twin framework, double board layer partition 18 C.1.1 General . 18 C.1.2 Installation of framework with channels and studs 19 C.2 Installation of plasterboards 20 C.2.1 General . 20 DIN EN 16703:2015-12 EN 16703:2015 (E) 3 C.2.2 Plasterboard inner layer on first side . 20 C.2.3 Plasterboard outer
19、layer on first side . 20 C.3 Installation of insulation in cavity 21 C.4 Installation of plasterboards 2nd side - Plasterboard inner layer on second side 21 C.5 Plasterboard outer layer on second side . 21 C.6 Jointing for both sides of the partition 21 Annex D (informative) Interlaboratory Tests pe
20、rformed for the development of this Test Code standard 22 Annex E (informative) E Modulus - Control Method (static E Modulus with 3 bending points) 24 Annex F (informative) E Modulus - Expertise Method (dynamic E Modulus) 25 Bibliography . 27 DIN EN 16703:2015-12 EN 16703:2015 (E) 4 European forewor
21、d This document (EN 16703:2015) has been prepared by Technical Committee CEN/TC 126 “Acoustic properties of building elements and of buildings”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical t
22、ext or by endorsement, at the latest by March 2016, and conflicting national standards shall be withdrawn at the latest by March 2016. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsibl
23、e for identifying any or all such patent rights. This standard is a complement to the European Standard EN ISO 10140-1 and is not intended to replace it. The complement includes more stringent rules, narrower tolerances and new, additional requirements. According to the CEN-CENELEC Internal Regulati
24、ons, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy
25、, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. DINEN 16703:2015-12EN 16703:2015 (E) 5 Introduction Product standard EN 520:2004+A1:2009 “Gypsum plasterboards Definitions, requireme
26、nts and test methods” specifies requirements and test methods and establishes how to declare characteristics and to affix the CE marking of products accordingly. In EN 520:2004+A1:2009, when a drywall partition with plasterboard and steel studs has an airborne sound insulation performance property,
27、its sound reduction should be determined in accordance with EN ISO 140-3, now replaced by EN ISO 10140-2. The measured sound reductions are calculated into sound reduction index R,in third octave bands and into single number indexes, in accordance with EN ISO 717-1. Those single number ratings are u
28、sed for the CE marking. Measurement of sound reduction according to EN ISO 10140-2 was known through earlier inter laboratory tests (ILT), to generate large spread in results from different laboratories. This was not suitable, either from a competition point of view or from an end-user perspective.
29、Therefore, CEN/TC 126 “Acoustic properties of building elements and of buildings” decided to set up a working group, WG 9 “Test Code for drywall partition with plasterboard and steel studs”, with the scope to improve reproducibility by developing a Test Code complementary to the EN ISO 10140-1. One
30、part of this work was to organize ILT for sound reduction measurements, to assess the uncertainty of acoustic quantities (Annex D). This was used by the working group to prepare this test code for drywall systems, including guidelines of testing installation and validation of laboratory, to decrease
31、 the level of uncertainty. DIN EN 16703:2015-12 EN 16703:2015 (E) 6 1 Scope This European Standard specifies information additional to EN ISO 10140-1 necessary to carry out efficiently and under standardized conditions the determination of the sound reduction index of drywall systems of plasterboard
32、 with steel studs according to EN ISO 10140-2 “Acoustics Laboratory measurement of sound insulation of -building elements Part 2: Measurement of airborne sound insulation”. Observe that all demands in EN ISO 10140-2 should still be fulfilled. In order to decrease the uncertainty, it specifies: addit
33、ional guidelines for testing drywall systems of plasterboard with steel studs; and a method to validate laboratory by using two reference test partitions. The results obtained are used to convert frequency-dependent sound reduction index into single number ratings, according to EN ISO 717-1. These p
34、erformances can be used to compare different products, or, and to express a requirement, or, and as input into estimation methods, such as EN 12354-1. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its applic
35、ation. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 520:2004+A1:2009, Gypsum plasterboards Definitions, requirements and test methods EN 13162, Thermal insulation products for buildi
36、ngs Factory made Mineral wool (MW) products Specification EN 13963, Jointing materials for gypsum boards Definitions, requirements and test methods EN 14195, Metal framing components for gypsum board systems Definitions, requirements and test methods EN 14566, Mechanical fasteners for gypsum plaster
37、board systems Definitions, requirements and test methods EN ISO 10140 (all parts), Acoustics Laboratory measurement of sound insulation of building elements (ISO 10140, all parts) 3 Terms and definitions For the purposes of this document, the following term and definition apply. 3.1 drywall system o
38、f plasterboard with steel studs partition comprising a non load bearing metal frame partition enclosed by plasterboards DIN EN 16703:2015-12 EN 16703:2015(E)7 4 Test code for drywall systems of plasterboard with steel studs 4.1 Application 4.1.1 This standard applies to non-load bearing metal frame
39、partition comprising a metal frame enclosed by plasterboards. In general, the type, size, gauge and spacing of the studs, and the size, type and number of layers of plasterboard and eventual amount and type of cavity filling material in partition constructions are determined by the performance requi
40、rements of the system. 4.1.2 The quantity to be determined is the sound reduction index R as a function of frequency. The definition of R is given in EN ISO 10140-2. 4.2 Testing Guidelines 4.2.1 Test element The partition size shall be between 9 m2 12 m2. For all others information, refer to EN ISO
41、10140-1 and EN ISO 10140-2. 4.2.2 Boundary and mounting conditions 4.2.2.1 General rules The test element shall be mounted directly on the facilities frame; it shall not be a prefabricated full partition. The test element should be installed in a similar manner to the actual construction with carefu
42、l simulation of typical connections and sealing conditions at the perimeter and at all joints. 4.2.2.2 Perimeters mounting A gap of about 5 mm to 10 mm shall remain between the plasterboards and the reveal of the test opening. This gap shall be filled with appropriate material. Drying time has to re
43、spect product instruction according to 4.3.1 because the type of filler will have an influence on the performance of the partition. Cracks in the perimeter may occur, resulting in air leakage. To control risk a procedure shall be set in the laboratory to check this. This shall be at minimum a visual
44、 control but can also be any additional method. 4.2.2.3 Partition positions The sound reduction index of drywall system of plasterboard with steel studs is influenced by the mounting conditions in the test opening of the laboratory. Important installation parameters include the niche depth and the p
45、osition of the partition in relation to the acoustic break in the test aperture. The partition shall be installed into the test opening so that the niches on both sides of the partition have different depths with a ratio of 2:1. To improve the reproducibility between laboratories and facilitate comp
46、arison of sound reduction indices for different drywall system of plasterboard with steel studs, the partition (even double wall) shall not be mounted across the acoustic break between sending and receiving room of the laboratory, but on the same side of the break as indicated in Annex A. Main mount
47、ing conditions are reported in Annex A; others may be used but shall be fully described in the test report. DINEN 16703:2015-12EN 16703:2015 (E) 8 NOTE Mounting the lightweight partition with one leaf on one side and the other leaf on the other side of the acoustic break can result in higher values
48、for the sound reduction index. Other mounting conditions may be suitable for certain types of twin leaf walls, for example, walls for semidetached houses where the leaves are vibrationally uncoupled (for example on separate foundations). In such cases the wall leaves can be mounted on each side of the acoustic break. No absorption material should be located close (less than 1 m) to the perimeter of the partition. The acoustic break has to be covered with soft reflecting materials. 4.2.3 Test report The