1、December 2015 English price group 25No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 91.100.40!%J-d“2391065www.din.d
2、eDIN EN 494Fibre-cement profiled sheets and fittings Product specification and test methods;English version EN 494:2012+A1:2015,English translation of DIN EN 494:2015-12Faserzement-Wellplatten und dazugehrige Formteile Produktspezifikation und Prfverfahren;Englische Fassung EN 494:2012+A1:2015,Engli
3、sche bersetzung von DIN EN 494:2015-12Plaques profiles en fibres-ciment et accessoires Spcifications du produit et mthodes dessai;Version anglaise EN 494:2012+A1:2015,Traduction anglaise de DIN EN 494:2015-12SupersedesDIN EN 494:2013-01See start of applicationwww.beuth.deDocument comprises 73 pagesD
4、Translation by DIN-Sprachendienst.In case of doubt, the German-language original shall be considered authoritative.11.15 DIN EN 494:2015-12 2 A comma is used as the decimal marker. Start of application The start of application of this standard is 2015-12-01. It should be noted that, in Germany, CE c
5、onformity marking of construction products will be permitted once this standard has been listed in the Official Journal of the European Union and/or the Bundesanzeiger (German Federal Gazette) and from the date given therein. For further information, users of this standard should refer to the websit
6、es of the European Commission or of the relevant building authority. The standard which this document replaces, DIN EN 494:2013-01, may be used in parallel with this standard during a specified transition period where such has been laid down in the Official Journal of the European Union and/or the B
7、undesanzeiger (German Federal Gazette). National foreword This document (EN 494:2012+A1:2015) has been prepared by Technical Committee CEN/TC 128 “Roof covering products for discontinuous laying and products for wall cladding” (Secretariat: NBN, Belgium). The responsible German body involved in its
8、preparation was DIN-Normenausschuss Bauwesen (DIN Standards Committee Building and Civil Engineering), Working Committee NA 005-02-04 AA Faserzementplatten (SpA zu CEN/TC 128/SC 4 und ISO/TC 77). Amendments This standard differs from DIN EN 494:2013-01 as follows: a) The standard has been brought in
9、 line with the new EU Construction Products Regulation (CPR) by the addition of a new Annex ZA as well as Clause 6, “Assessment and verification of constancy of performance AVCP”. The standard has also been editorially revised. Previous editions DIN EN 494: 1995-08, 1999-07, 2006-04, 2007-06, 2013-0
10、1 DIN EN Corrigendum 1: 1997-04 DIN EN 494/A2: 2006-12 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 494:2012+A1 September 2015 ICS 91.100.40 Supersedes EN 494:2012English Version Fibre-cement profiled sheets and fittings - Product specification and test methods Plaques profiles en fibres-cim
11、ent et accessoires - Spcifications du produit et mthodes dessai Faserzement-Wellplatten und dazugehrige Formteile - Produktspezifikation und Prfverfahren This European Standard was approved by CEN on 11 August 2012 and includes Amendment 1 approved by CEN on 6 June 2015. CEN members are bound to com
12、ply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELE
13、C Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the s
14、ame status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembour
15、g, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey andUnited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 20
16、15 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 494:2012+A1:2015 EEN 494:2012+A1:2015 (E) 2 Contents Page European foreword . 4 1 Scope 5 2 Normative references 5 3 Terms and definitions . 6 4 Symbols and abbreviations . 7 5 Pro
17、duct requirements . 8 5.1 General 8 5.1.1 Composition 8 5.1.2 Appearance and finish . 8 5.2 Dimensions and tolerances . 9 5.2.1 General 9 5.2.2 Categorisation by height of profile . 9 5.2.3 Thickness . 9 5.2.4 Tolerances on nominal dimensions 10 5.3 Physical requirements and characteristics for fibr
18、e-cement profiled sheets . 11 5.3.1 General . 11 5.3.2 Apparent density 11 5.3.3 Mechanical characteristics . 11 5.3.4 Water impermeability 12 5.4 Durability requirements . 12 5.4.1 General . 12 5.4.2 Freeze-thaw 12 5.4.3 Heat-rain . 13 5.4.4 Warm water . 13 5.4.5 Soak-dry . 13 5.5 Summary of charac
19、teristics and classification 13 5.5.1 Summary of characteristics 13 5.5.2 Classification 13 5.6 Fire and safety . 14 5.6.1 External fire performance 14 5.6.2 Reaction to fire 14 5.6.3 Release of dangerous substances . 14 5.7 Product information . 14 6 Assessment and verification of constancy of perf
20、ormance - AVCP 15 6.1 General . 15 6.2 Type testing 15 6.2.1 General . 15 6.2.2 Test samples, testing and compliance criteria 16 6.2.3 Test reports 16 6.3 Factory production control (FPC) 16 6.3.1 General . 16 6.3.2 Requirements 17 6.3.3 Product specific requirements 19 6.3.4 Initial inspection of f
21、actory and of FPC 19 6.3.5 Continuous surveillance of FPC . 20 DIN EN 494:2015-12 EN 494:2012+A1:2015 (E) 3 6.3.6 Procedure for modifications . 20 6.4 Inspection of a consignment of finished products 20 7 Test methods 21 7.1 General . 21 7.2 Dimensional tests . 21 7.2.1 Dimensional tests for sheets.
22、 21 7.2.2 Dimensional tests for fittings . 24 7.3 Tests for physical performance and characteristics 24 7.3.1 Apparent density 24 7.3.2 Mechanical characteristics 25 7.3.3 Water impermeability 28 7.3.4 Warm water 29 7.3.5 Soak-dry . 30 7.4 Tests for climatic performance 31 7.4.1 Freeze-thaw 31 7.4.2
23、 Heat-rain 33 7.4.3 Freeze-thaw test for fittings 34 7.5 Test for fire performance 34 7.5.1 Test for external fire performance . 34 7.5.2 Test for reaction to fire . 35 8 Marking, labelling and packaging . 40 Annex A (normative) Figures 41 Annex B (normative) Consignment inspection sampling 53 Annex
24、 C (normative) Statistical method for determining the corresponding wet values or revised dry specifications for the breaking load and/or bending moment when carrying out the dry method of test for quality control purposes 54 C.1 Procedure 54 C.2 Determination of the correlation between the results
25、of testing wet and dry specimens 54 C.3 Determination of the regression line 55 C.4 Determination of a value for wet testing from an obtained value for dry testing 55 C.5 Determination of the minimum value specified for dry testing xstdcorresponding to the minimum value specified for wet testing in
26、this document ystd. 56 Annex ZA (informative) !Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation“ . 58 ZA.1 Scope and relevant characteristics 58 ZA.2 Procedure for AVCP of fibre - cement profiled sheets and fittings . 60 ZA.2.1 Systems of AVCP 60
27、 ZA.2.2 Declaration of performance (DoP) . 65 ZA.3 CE marking and labelling . 68 Bibliography . 71 DIN EN 494:2015-12 EN 494:2012+A1:2015 (E) 4 European foreword This document (EN 494:2012+A1:2015) has been prepared by Technical Committee CEN/TC 128 “Roof covering products for discontinuous laying a
28、nd products for wall cladding“, the secretariat of which is held by NBN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by March 2016, and conflicting national standards shall be withdrawn at the la
29、test by June 2017. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document includes Amendment 1 approved by CEN on 6 June 2015.
30、This document supersedes !EN 494:2012“. The start and finish of text introduced or altered by amendment is indicated in the text by tags !“. !This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requir
31、ements of the EU Construction Products Regulation 305/2011. For relationship with the EU Regulation 305/2011, see informative Annex ZA, which is an integral part of this document.“ !When comparing EN 494:2004+A3:2007 and the previous edition EN 494:2012, the following paragraphs had been changed or
32、added: 3.10, 3.11, 5.1.1, Table 2, 5.3.3.1, 5.3.3.4, 5.6.3, Table 6, 6.3.2, 7.4.2.1 and Annex ZA.“ A distinction has been made between product appraisal (type tests) and routine quality control requirements (acceptance tests). The performance of a roof or another building part constructed with these
33、 products depends not only on the properties of the product as required by this document, but also on the design, construction and installation of the components as a whole in relation to the environment and conditions of use. According to the CEN-CENELEC Internal Regulations, the national standards
34、 organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxemb
35、ourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. DIN EN 494:2015-12 EN 494:2012+A1:2015 (E) 5 1 Scope This European Standard specifies the technical requirements and establishes methods of control and test as
36、well as acceptance conditions for fibre-cement profiled sheets and their fibre-cement fittings for one or more of the following uses: roofing; internal wall finishes; external wall and ceiling finishes. For the purpose of this European Standard, fibre-cement profiled sheets are classified according
37、to their height of corrugation and their mechanical characteristics. This European Standard covers fibre-cement profiled sheets reinforced with fibres of different type as specified in 5.1.1, with and without factory applied coating. This European Standard does not include calculations with regard t
38、o works, design requirements, installation techniques, wind uplift or rain proofing of the installed sheets. NOTE Some of these requirements can be applied, after agreement, to curved sheets for specific applications. 2 Normative references The following documents, in whole or in part, are normative
39、ly referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 197-1, Cement Part 1: Composition, specifications and conformit
40、y criteria for common cements CEN/TS 1187 Test methods for external fire exposure to roofs EN 13501-1, Fire classification of construction products and building elements Part 1: Classification using test data from reaction to fire tests EN 13501-5, Fire classification of construction products and bu
41、ilding elements Part 5: Classification using data from external fire exposure to roofs tests EN 13823, Reaction to fire tests for building products Building products excluding floorings exposed to the thermal attack by a single burning item EN 15057, Fibre cement profiled sheets - Impact resistance
42、test method EN ISO 1716, Reaction to fire tests for products Determination of the gross heat of combustion (calorific value) (ISO 1716) ISO 2602, Statistical interpretation of test results Estimation of the mean Confidence interval ISO 2859-1, Sampling procedures for inspection by attributes Part 1:
43、 Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection ISO 3951-1, Sampling procedures for inspection by variables Part 1: Specification for single sampling plans indexed by acceptance quality limit (AQL) for lot-by-lot inspection for a single quality characteristic an
44、d a single AQL DIN EN 494:2015-12 EN 494:2012+A1:2015 (E) 6 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 profiled sheet component the cross section of which consists of corrugations as in the examples shown in !Figure A.1“ Note 1 to entry:
45、 The corrugations are defined by their pitch a and their height h. 3.2 acceptance test test to establish whether a batch of sheets, drawn either from continuous production or from a consignment, conforms to a specification Note 1 to entry: Test methods and specification limit values are specified in
46、 this document. Sampling levels and acceptance criteria are given in !6.2.2“. 3.3 type test test carried out to demonstrate conformity with the requirements of this document or for the approval of a new product and/or when a fundamental change is made in formulation and/or method of manufacture, the
47、 effects of which cannot be predicted on the basis of previous experience Note 1 to entry: The test is performed on the as delivered product, but is not required for each production batch. 3.4 acceptable quality level (AQL) quality level which in a sampling plan corresponds to a specified, relativel
48、y high probability of acceptance Note 1 to entry: It is the maximum percent defective (or maximum number of defects per 100 units) that for purposes of sampling inspection can be considered satisfactory as a process average. Note 2 to entry: A sampling scheme with an AQL of 4 % means that batches co
49、ntaining up to 4 % defective items have a high probability of acceptance. 3.5 as delivered same condition as the producer intends to supply the product after completing all aspects of the process including maturing and, when appropriate, painting 3.6 short sheet sheet having a length less than or equal to 0,9 m 3.7 long sheet sheet having a length greater than 0,9 m DIN EN 494:2015-12 EN 494:2012+A1:2015 (E) 7 3.8 upper face face normally exposed to the weather