    DIN EN 12200-1-2016 Plastics rainwater piping systems for above ground external use - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1 Specifications for pipes fittings and the .pdf

    • 资源ID:664413       资源大小:2MB        全文页数:36页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    DIN EN 12200-1-2016 Plastics rainwater piping systems for above ground external use - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1 Specifications for pipes fittings and the .pdf

    1、October 2016 English price group 15No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 23.040.05; 23.040.20!%.“2579911w

    2、ww.din.deDIN EN 12200-1Plastics rainwater piping systems for above ground external use Unplasticized poly(vinyl chloride) (PVCU) Part 1: Specifications for pipes, fittings and the system;English version EN 122001:2016,English translation of DIN EN 12200-1:2016-10KunststoffRohrleitungssysteme fr auen

    3、liegende Regenfallleitungen Weichmacherfreies Polyvinylchlorid (PVCU) Teil 1: Anforderungen an Rohre, Formstcke und das Rohrleitungssystem;Englische Fassung EN 122001:2016,Englische bersetzung von DIN EN 12200-1:2016-10Systmes de canalisations de descentes deaux pluviales en plastique usage externe

    4、en arien Poly(chlorure de vinyle) non plastifi (PVCU) Partie 1: Spcifications pour tubes, raccords et le systme;Version anglaise EN 122001:2016,Traduction anglaise de DIN EN 12200-1:2016-10SupersedesDIN EN 122001:200101www.beuth.deDTranslation by DIN-Sprachendienst.In case of doubt, the German-langu

    5、age original shall be considered authoritative.Document comprises 36 pages 09.16 2A comma is used as the decimal marker. National foreword This document (EN 12200-1:2016) has been prepared by Technical Committee CEN/TC 155 “Plastics piping systems and ducting systems” (Secretariat: NEN, Netherlands)

    6、. The responsible German body involved in its preparation was DIN-Normenausschuss Wasserwesen (DIN Standards Committee Water Practice), Working Committee NA 119-05-28-07 GUA Hausabflussleitungen of Joint Working Committee NA 119-05-28 AA Kunststoffrohre in der Abwassertechnik. Amendments This standa

    7、rd differs from DIN EN 12200-1:2001-01 as follows: a) standards for test methods have been updated; b) in Clause 3, terms for multilayer pipes according to CEN ISO/TR 27165 and material terms have been included; c) information on acrylic polymers has been added; d) Annex B “Survey of possible use of

    8、 reprocessed and recycled material” has been added. Previous editions DIN EN 12200-1: 2001-01 DIN EN 12200-1:2016-10EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12200-1 April 2016 ICS 23.040.20 Supersedes EN 12200-1:2000English Version Plastics rainwater piping systems for above ground exter

    9、nal use - Unplasticized poly(vinyl chloride) (PVC-U) -Part 1: Specifications for pipes, fittings and the system Systmes de canalisations de descentes deaux pluviales en plastique usage externe en arien - Poly(chlorure de vinyle) non plastifi (PVC-U) - Partie 1: Spcifications pour tubes, raccords et

    10、le systme Kunststoff-Rohrleitungssysteme fr auenliegende Regenfallleitungen - Weichmacherfreies Polyvinylchlorid (PVC-U) - Teil 1: Anforderungen an Rohre, Formstcke und das Rohrleitungssystem This European Standard was approved by CEN on 9 January 2016. CEN members are bound to comply with the CEN/C

    11、ENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centr

    12、e or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the

    13、official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherla

    14、nds, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey andUnited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CEN All rights

    15、of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12200-1:2016 EEN 12200-1:2016 (E) 2 Contents Page European foreword . 4 1 Scope 6 2 Normative references 6 3 Terms, definitions, symbols and abbreviations . 7 3.1 Terms and definitions 7 3.2 Definit

    16、ions of multilayer pipes . 8 3.3 Material terms and definitions . 9 3.4 Definitions for brackets 9 3.5 Symbols 10 3.6 Abbreviations 10 4 Material 10 4.1 PVC-U material 10 4.2 Other materials . 11 4.3 Utilization of non-virgin material . 11 4.4 Sealing ring retaining means 11 4.5 Metallic brackets 11

    17、 5 General characteristics - appearance 11 6 Geometrical characteristics 11 6.1 General . 11 6.2 Dimensions of pipes 11 6.2.1 Diameters of circular pipes . 11 6.2.2 Outside dimensions and tolerances of non-circular pipes 12 6.2.3 Effective length of pipes . 13 6.2.4 Wall thicknesses of pipes and the

    18、ir sockets . 13 6.2.5 Dimensions of sockets 15 6.3 Dimensions of fittings . 15 6.3.1 Nominal size(s) 15 6.3.2 Wall thicknesses of fittings . 15 6.3.3 Angles 15 6.3.4 Design lengths (Zd) 15 6.4 Diameters and lengths of sockets and spigots . 15 6.4.1 Ring seal sockets and spigots . 15 6.4.2 Solvent ce

    19、ment and unsealed sockets and spigots . 17 6.4.3 Non-circular sockets and spigots 19 6.4.4 Spigot sleeves . 19 6.5 Types of fittings . 19 6.6 Brackets . 22 7 Mechanical characteristics 22 7.1 Pipes 22 7.2 Mechanical characteristics of anchor brackets . 24 8 Physical characteristics 25 8.1 Physical c

    20、haracteristics of pipes . 25 8.2 Physical characteristics of fittings . 26 DIN EN 12200-1:2016-10EN 12200-1:2016 (E) 39 Fitness for purpose of joint and system . 26 10 Sealing rings . 27 11 Adhesives . 27 12 Marking 27 12.1 General . 27 12.2 Minimum required marking of pipes 28 12.3 Minimum required

    21、 marking of fittings . 28 12.4 Minimum required marking of brackets . 29 Annex A (informative) Utilization of non-virgin material 30 A.1 Own reprocessed material 30 A.2 External reprocessed and recycled material with agreed specification 30 A.3 External reprocessed and recycled material not covered

    22、by an agreed specification 31 Annex B (informative) Survey of possible use of reprocessed and recycled material . 33 Bibliography . 34 DIN EN 12200-1:2016-10 EN 12200-1:2016 (E) 4 European foreword This document (EN 12200-1:2016) has been prepared by Technical Committee CEN/TC 155 “Plastics piping s

    23、ystems and ducting systems”, the secretariat of which is held by NEN. This document supersedes EN 12200-1:2000. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2016, and conflicting nation

    24、al standards shall be withdrawn at the latest by October 2016. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This European Standard

    25、has been prepared in liaison with CEN/TC 128 “Roof covering products for discontinuous laying and products for wall cladding” taking into account EN 607 1 and EN 1462 and CEN/TC 165 “Waste water engineering” taking into account the design guidance in EN 12056-3 4. This standard is a Part of a System

    26、 Standard for plastics piping systems of a particular material for a specified application. There are a number of such System Standards. System Standards are based on the results of the work undertaken in ISO/TC 138 “Plastics pipes, fittings and valves for the transport of fluids”, which is a Techni

    27、cal Committee of the International Organization for Standardization (ISO). They are supported by separate standards on test methods to which references are made throughout the System Standard. The System Standards are consistent with general standards on functional requirements and on recommended pr

    28、actice for installation. EN 12200 consists of the following Parts, under the general title “Plastics rainwater piping systems for above ground external use Unplasticized poly(vinyl chloride) (PVC-U)”: Part 1: Requirements for pipes fittings and the system (the present standard); Part 2: Guide for th

    29、e assessment of conformity 3. For Rainwater discharge systems used internally within buildings the following standards apply: EN 1329, Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure Unplasticized poly(vinyl chloride) (PVC-U) EN 1451, Pla

    30、stics piping systems for soil and waste discharge (low and high temperature) within the building structure Polypropylene (PP) EN 1453, Plastics piping systems with structured-wall pipes for soil and waste discharge (low and high temperature) inside buildings Unplasticized poly(vinyl chloride) (PVC-U

    31、) DIN EN 12200-1:2016-10EN 12200-1:2016 (E) 5 EN 1455, Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure Acrylonitrile-butadiene-styrene (ABS) EN 1519, Plastics piping systems for soil and waste discharge (low and high temperature) within t

    32、he building structure Polyethylene (PE) EN 1565, Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure Styrene copolymer blends (SAN+PVC) EN 1566, Plastics piping systems for soil and waste discharge (low and high temperature) within the buildi

    33、ng structure Chlorinated poly(vinyl chloride) (PVC-C) According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finla

    34、nd, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. DIN EN 12200-1:2016-10 EN 12200-1

    35、:2016 (E) 6 1 Scope This European Standard specifies the requirements for pipes, fittings, brackets and the system of unplasticized poly(vinyl chloride) (PVC-U) intended for use as above-ground external rainwater piping systems. It also specifies: a) The requirements for metallic brackets. b) Both s

    36、olid wall pipes and fittings, (i.e. product manufactured from a single layer), as well as solid wall multi-layer pipes. c) The test parameters for the test methods referred to in this standard. Pipes can be used in conjunction with fittings and brackets of acrylic materials provided these polymers m

    37、eet the performance requirements of this standard. The products are usually used in conjunction with gutters conforming to EN 607 1. They are not intended for use with products conforming to EN 612 2. This standard is applicable to PVC-U rainwater systems of circular, square, rectangular or any othe

    38、r shape with sealed (rubber ring or solvent cement) or unsealed joints. This standard covers a range of pipes and fittings sizes. NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from the size range to take into account their particular requirements an

    39、d any relevant national regulations and installation practices or codes. NOTE 2 The term “rainwater” in this standard is used also to encompass “surface water” (as defined in EN 752 6) run-off from buildings. 2 Normative references The following documents, in whole or in part, are normatively refere

    40、nced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 513:1999, Unplasticized polyvinylchloride (PVC-U) profiles for the fabri

    41、cation of windows and doors - Determination of the resistance to artificial weathering EN 681-1, Elastomeric seals - Materials requirements for pipe joint seals used in water and drainage applications - Part 1: Vulcanized rubber EN 681-2, Elastomeric Seals - Materials requirements for pipe joint sea

    42、ls used in water and drainage applications - Part 2: Thermoplastic elastomers EN 1462, Brackets for eaves gutters - Requirements and testing EN 12095, Plastics piping systems - Brackets for rainwater piping systems - Test method for bracket strength CEN/TS 14541:2013, Plastics pipes and fittings - C

    43、haracteristics for utilisation of non-virgin PVC-U, PP and PE materials EN 14680, Adhesives for non-pressure thermoplastics piping systems - Specifications DIN EN 12200-1:2016-10EN 12200-1:2016 (E) 7EN 14814, Adhesives for thermoplastic piping systems for fluids under pressure - Specifications EN 20

    44、105-AO2, Textiles Tests for colour fastness Part A02: Grey scale for assessing change in colour (ISO 105-A02) EN ISO 306, Plastics - Thermoplastic materials - Determination of Vicat softening temperature (VST) (ISO 306) EN ISO 472, Plastics - Vocabulary (ISO 472) EN ISO 580, Plastics piping and duct

    45、ing systems - Injection-moulded thermoplastics fittings - Methods for visually assessing the effects of heating (ISO 580) EN ISO 1043-1, Plastics - Symbols and abbreviated terms - Part 1: Basic polymers and their special characteristics (ISO 1043-1) EN ISO 2505, Thermoplastics pipes - Longitudinal r

    46、eversion - Test method and parameters (ISO 2505) EN ISO 3126, Plastics piping systems - Plastics components - Determination of dimensions (ISO 3126) EN ISO 4892-2, Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps (ISO 4892-2) EN ISO 4892-3, Plastics - Methods of e

    47、xposure to laboratory light sources - Part 3: Fluorescent UV lamps (ISO 4892-3) EN ISO 8256, Plastics - Determination of tensile-impact strength (ISO 8256) ISO 3127, Thermoplastics pipes Determination of resistance to external blows Round-the-clock method ISO 6259-2, Thermoplastics pipes Determinati

    48、on of tensile properties Part 2: Pipes made of unplasticized poly(vinyl chloride) (PVC-U), chlorinated poly (vinyl chloride) (PVC-C) and high-impact poly (vinyl chloride) (PVC-HI) ISO 13254, Thermoplastics piping systems for non-pressure applications Test method for water tightness 3 Terms, definiti

    49、ons, symbols and abbreviations For the purposes of this document, the following terms, definitions, symbols and abbreviations apply. 3.1 Terms and definitions In addition to the terms and definitions given below, the terms and definitions given in EN ISO 472 and EN ISO 1043-1 apply. 3.1.1 nominal size DN numerical designation of the size of a component, other than a component designated by thread size, which is approxi


    注意事项

    本文(DIN EN 12200-1-2016 Plastics rainwater piping systems for above ground external use - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1 Specifications for pipes fittings and the .pdf)为本站会员(proposalcash356)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!