欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    CLC TR 62453-503-1-2009 Field device tool (FDT) interface specification - Part 503-1 Communication implementation for common object model - IEC 61784 CP 3 1 and CP 3 2《现场装置工具(FDT)接.pdf

    • 资源ID:629557       资源大小:1.88MB        全文页数:50页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    CLC TR 62453-503-1-2009 Field device tool (FDT) interface specification - Part 503-1 Communication implementation for common object model - IEC 61784 CP 3 1 and CP 3 2《现场装置工具(FDT)接.pdf

    1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationField device tool (FDT) interfacespecification Part 503-1: Communication implementation for common object model IEC 61784 CP 3/1 and CP 3/2PD CLC/TR 62453-503-1:2009National fore

    2、wordThis Published Document is the UK implementation of CLC/TR 62453-503-1:2009.The UK participation in its preparation was entrusted to Technical CommitteeAMT/7, Industrial communications: process measurement and control, including fieldbus.A list of organizations represented on this committee can

    3、be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2010ISBN 978 0 580 62570 1ICS 25.040.40; 35.100.05; 35.110Compliance with a British Standard cannot confer immunity fr

    4、omlegal obligations.This Published Document was published under the authority of theStandards Policy and Strategy Committee on 31 January 2010Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDPD CLC/TR 62453-503-1:2009TECHNICAL REPORT CLC/TR 62453-503-1 RAPPORT TECHNIQUE

    5、TECHNISCHER BERICHT November 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any

    6、 form and by any means reserved worldwide for CENELEC members. Ref. No. CLC/TR 62453-503-1:2009 E ICS 25.040.40; 35.100.05; 35.110 English version Field device tool (FDT) interface specification - Part 503-1: Communication implementation for common object model - IEC 61784 CP 3/1 and CP 3/2 (IEC/TR

    7、62453-503-1:2009) Spcification des interfaces des outils des dispositifs de terrain (FDT) - Partie 503-1: Implmentation des communications pour le modle objet commun - CEI 61784 CP 3/1 et CP 3/2 (CEI/TR 62453-503-1:2009) Field Device Tool (FDT)-Schnittstellenspezifikation - Teil 503-1: Kommunikation

    8、simplementierung mit dem allgemeinen Objektmodell (COM) - Kommunikationsprofile (CP) 3/1 und 3/2 nach IEC 61784 (IEC/TR 62453-503-1:2009) This Technical Report was approved by CENELEC on 2009-10-01. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, t

    9、he Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. PD CLC/TR 62453-503-1:2009CLC/TR 6

    10、2453-503-1:2009 - 2 - Foreword The text of document 65E/67/CDV, future edition 1 of IEC/TR 62453-503-1, prepared by SC 65E, Devices and integration in enterprise systems, of IEC TC 65, Industrial-process measurement, control and automation, was submitted to the IEC-CENELEC parallel vote and was appr

    11、oved by CENELEC as CLC/TR 62453-503-1 on 2009-10-01. This standard is to be used in conjunction with EN 62453-3xy series. Annex ZA has been added by CENELEC. _ Endorsement notice The text of the Technical Report IEC/TR 62453-503-1:2009 was approved by CENELEC as a Technical Report without any modifi

    12、cation. In the official version, for Bibliography, the following note has to be added for the standard indicated: IEC 61784-1 NOTE Harmonized as EN 61784-1:2008 (not modified). _ PD CLC/TR 62453-503-1:2009- 3 - CLC/TR 62453-503-1:2009 Annex ZA (normative) Normative references to international public

    13、ations with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) appl

    14、ies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 61158 series Industrial communication networks - Fieldbus specifications EN 61158 series IEC 62453-1 2009 Field device tool (FD

    15、T) interface specification - Part 1: Overview and guidance EN 62453-1 2009 IEC 62453-2 2009 Field device tool (FDT) interface specification - Part 2: Concepts and detailed description EN 62453-2 2009 IEC/TR 62453-41 2009 Field device tool (FDT) interface specification - Part 41: Object model integra

    16、tion profile - Common object model CLC/TR 62453-41 2009 IEC 62453-303-1 2009 Field device tool (FDT) interface specification - Part 303-1: Communication profile integration - IEC 61784 CP 3/1 and CP 3/2 EN 62453-303-1 2009 _ PD CLC/TR 62453-503-1:2009 2 TR 62453-503-1 IEC:2009(E) CONTENTS INTRODUCTI

    17、ON.6 1 Scope.7 2 Normative references .7 3 Terms, definitions, symbols, abbreviated terms and conventions 7 3.1 Terms and definitions 7 3.2 Symbols and abbreviated terms.7 3.3 Conventions 8 3.3.1 Data type names and references to data types 8 3.3.2 Vocabulary for requirements8 4 Bus category 8 5 Acc

    18、ess to instance and device data8 6 Protocol specific behavior.8 6.1 General .8 6.2 Representing modularity9 6.2.1 Monolithic DTMs9 6.2.2 Modular DTMs .10 6.3 Interfaces and Information related to Bus Master Configuration.13 6.4 Configuration changes in a device.13 6.5 Error behavior: DTM refuses new

    19、 BMCP .14 7 Protocol specific usage of general data types.14 8 Network management data types15 8.1 General .15 8.2 PROFIBUS device address15 8.3 Master-bus parameter set15 8.4 Slave bus parameter set15 8.5 Module and channel data 15 9 Communication data types .18 9.1 General .18 9.2 DPV0 communicati

    20、on FDTProfibusDPV0CommunicationSchema .18 9.3 DPV1 communication FDTProfibusDPV1CommunicationSchema .20 10 Channel parameter data types23 11 Device identification .25 11.1 Device type identification data types FDTProfibusIdentSchema25 11.2 Topology scan data types DTMProfibusDeviceSchema.26 11.3 Sca

    21、n identification data types FDTProfibusScanIdentSchema 26 11.4 Device type identification data types FDTProfibusDeviceIdentSchema .29 11.5 XSLT Transformation 30 Annex A (informative) Example documents for a DTM representing a Remote I/O43 Bibliography46 Figure 1 Part 503-1 of the IEC 62453 series 6

    22、 Figure 2 Example: Device DTM9 Figure 3 Example: Gateway DTM.10 Figure 4 Example: Modular DTM11 PD CLC/TR 62453-503-1:2009TR 62453-503-1 IEC:2009(E) 3 Figure 5 Example: Modular Gateway DTM .12 Figure 6 Interfaces and information related to bus master configuration.13 Figure 7 User changes the config

    23、uration of a device in the DTMs user interface 14 Figure 8 Error case: DTM refuses the new BMCP from the frame.14 Table 1 Protocol specific usage of general data types15 PD CLC/TR 62453-503-1:2009 6 TR 62453-503-1 IEC:2009(E) INTRODUCTION This part of IEC 62453 is an interface specification for deve

    24、lopers of FDT (Field Device Tool) components for function control and data access within a client/server architecture. The specification is a result of an analysis and design process to develop standard interfaces to facilitate the development of servers and clients by multiple vendors that need to

    25、interoperate seamlessly. With the integration of fieldbusses into control systems, there are a few other tasks which need to be performed. In addition to fieldbus- and device-specific tools, there is a need to integrate these tools into higher-level system-wide planning- or engineering tools. In par

    26、ticular, for use in extensive and heterogeneous control systems, typically in the area of the process industry, the unambiguous definition of engineering interfaces that are easy to use for all those involved is of great importance. A device-specific software component, called DTM (Device Type Manag

    27、er), is supplied by the field device manufacturer with its device. The DTM is integrated into engineering tools via the FDT interfaces defined in this specification. The approach to integration is in general open for all kind of fieldbusses and thus meets the requirements for integrating different k

    28、inds of devices into heterogeneous control systems. Figure 1 shows how IEC/TR 62453-503-1 is aligned in the structure of IEC 62453 series. Part 503-1Communicationimplementationfor common object model IEC 61784 CP 3/1and CP 3/2Figure 1 Part 503-1 of the IEC 62453 series PD CLC/TR 62453-503-1:2009TR 6

    29、2453-503-1 IEC:2009(E) 7 FIELD DEVICE TOOL (FDT) INTERFACE SPECIFICATION Part 503-1: Communication implementation for common object model IEC 61784 CP 3/1 and CP 3/2 1 Scope IEC 62435-503-1, which is a technical report, provides information for integrating the PROFIBUS protocol into the FDT interfac

    30、e specification (IEC 62453-2). This part of IEC 62453 specifies communication and other services. This specification neither contains the FDT specification nor modifies it. 2 Normative references The following referenced documents are indispensable for the application of this specification. For date

    31、d references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies IEC 61158 (all parts), Industrial communication networks Fieldbus specifications IEC 62453-1:2009, Field Device Tool (FDT) interface specification Pa

    32、rt 1: Overview and guidance IEC 62453-2:2009, Field Device Tool (FDT) interface specification Part 2: Concepts and detailed description IEC/TR 62453-41:2009 Field Device Tool (FDT) interface specification Part 41: Object model integration profile Common object model IEC 62453-303-1:2009 Field Device

    33、 Tool (FDT) interface specification Part 303-1: Communication profile integration - IEC 61784 CP 3/1 and CP 3/2 3 Terms, definitions, symbols, abbreviated terms and conventions 3.1 Terms and definitions For the purpose of this document, the terms and definitions given in IEC 62453-1 and IEC 62453-2

    34、apply. 3.2 Symbols and abbreviated terms For the purpose of this document, the symbols and abbreviations given in IEC 62453-1, IEC 62453-2 and the following apply. UML Unified Modelling Language ISO/IEC 19501 PD CLC/TR 62453-503-1:2009 8 TR 62453-503-1 IEC:2009(E) 3.3 Conventions 3.3.1 Data type nam

    35、es and references to data types The conventions for naming and referencing of data types are explained in IEC 62453-2 Clause A.1 3.3.2 Vocabulary for requirements The following expressions are used when specifying requirements. Usage of “shall” or “Mandatory” No exceptions allowed. Usage of “should”

    36、 or “Recommended” Strong recommendation. It may make sense in special exceptional cases to differ from the described behavior. Usage of “can or “Optional Function or behavior may be provided, depending on defined conditions. 4 Bus category IEC 61784 CP 3/1 and CP3/2 protocols are identified in the a

    37、ttribute busCategory of BusCategory element by the identifiers, as specified in IEC 62453-303-1. IEC 61784 CPF 3 protocols are using the identifiers in physicalLayer members within PhysicalLayer data type as specified in IEC 62453-303-1. 5 Access to instance and device data Used at methods: IDtmPara

    38、meter:GetParameters() IDtmParameter:SetParameters() These methods shall provide access to at least to all parameters defined in IEC 62453-303-1. 6 Protocol specific behavior 6.1 General A DTM shall deliver its GSD information via method IDtmInformation:GetInformation() and IDtmParameter:GetParameter

    39、s(). GSD information is provided in the attribute . Also it is required to provide a GSD file for each supported device type on the hard drive. The attribute in the DTMParameter document specifies the location of the GSD file. It is expected that a Profibus DTM in the attribute deviceTypeInformation

    40、 is exposing exactly the GSD file which is referenced by the attribute deviceTypeInformationPath. If the GSD depends on bus settings, a DTMs configuration or parameterization dialog could be used to change bus settings. Based on these settings, updated GSD information can be inserted in the informat

    41、ion document. Here too the DTM has to call IFdtContainer:SaveRequest() and IDtmEvents:OnParameterChanged(). PD CLC/TR 62453-503-1:2009TR 62453-503-1 IEC:2009(E) 9 Notice that the internal device structure () with its modules and channels has to be updated as well. An example for documents of a DTM r

    42、epresenting a remote I/O can be found in Annex A. 6.2 Representing modularity 6.2.1 Monolithic DTMs Monolithic DTMs should always provide at least one element. A monolithic DTM that represents a modular device shall provide the structure information as part of the element. The IO values of the devic

    43、e are represented by Process Channels, which are referenced by child elements of the elements. If any of the modules provides communication, the respective element shall reference a Communication Channel. Example 1: A monolithic DTM for a PROFIBUS PA device will provide the information about instant

    44、iated modules in the element. Each instantiated module will be represented as a element. (Be aware: it is necessary to define an element for each element.) The IO values of the modules are represented as Process Channels, which are referenced by child elements of the elements. (see Figure 2) DTMProc

    45、essChannelFigure 2 Example: Device DTM This means: The DTM shall provide an internal topology in the parameter document to inform the frame about the internal structure of the device. The internal topology shall also include the module structure (element ). The DTM shall provide all channels in the

    46、channel collection based on the current configuration. When the DTM changes the configuration of the process data or the module configuration the Process Channels shall be updated. This means Process Channels shall be removed/added and the parameter document shall be updated (e.g. by adding/removing

    47、 elements) if necessary. Each channel is represented by a channel reference that is child of a element in the parameter document. Each channel object delivers a document based on the FDTProfibusChannelParameterSchema in IFdtChannel:GetChannelParameters() for the supported protocol. Example 2: A mono

    48、lithic Gateway DTM for a remote I/O system, which requires PROFIBUS communication and has some PD CLC/TR 62453-503-1:2009 10 TR 62453-503-1 IEC:2009(E) modules, which provide HART communication will provide Communication Channels for HART modules that are also Process Channels and “pure” Process Cha

    49、nnels for non-HART modules. (see Figure 3) DTMCombinedProcessandCommunicationChannelProcessChannelFigure 3 Example: Gateway DTM This means: The DTM shall provide all channels in the channel collection based on the current configuration. When the DTM changes the configuration of the process data or the module configuration the Process Channels shall be updated. This means Process Channels shall be removed/added and the p


    注意事项

    本文(CLC TR 62453-503-1-2009 Field device tool (FDT) interface specification - Part 503-1 Communication implementation for common object model - IEC 61784 CP 3 1 and CP 3 2《现场装置工具(FDT)接.pdf)为本站会员(ideacase155)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开