    BS IEC 61010-3-061-1999 Safety requirements for electrical equipment for measurement control and laboratory use - Conformity verification report for IEC 61010-2-061 particular requh.pdf

    • 资源ID:582974       资源大小:2.16MB        全文页数:65页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    BS IEC 61010-3-061-1999 Safety requirements for electrical equipment for measurement control and laboratory use - Conformity verification report for IEC 61010-2-061 particular requh.pdf

    1、BRITISH STANDARD Safety requirements for BS IEC 6 10 10-3-061 : electrical equipment for measurement, control, and laboratory use - Part 3-061: Conformity verification report for IEC 61010-2-061, Particular requirements for Iaboratory atomic spectrometers with thermal atomization and ionzation ICs 0

    2、3.120.20; 19.080; 71.040.10 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BS IEC 61010-3-061:1999 direction of the Electrotechnical Amd. No. Date Sector Committee, was published under the authority of the Standards Committee and comes into effect on 15 October 1999 National

    3、foreword Comments This British Standard reproduces verbatim IEC 610103061:1999 and implements it as the UK national standard- The UK participation in its preparation was entrusted to Technical Committee EPUM, Safety requirements for electrical equipment for measurement, control, and laboratory use,

    4、which has the responsibility to: - aid enquirers to understand the text; - present to the responsible internationaUEuropean committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; - monitor related international and European developments and promul

    5、gate them in the UK A list of organizations represented on this committee can be obtained on request to its secretary. From 1 January 1997, all IEC publications have the number 60000 added to the old number. For instance, IEC 27-1 has been renumbered as IEC 60027-1. For a period of time during the c

    6、hange over from one numbering system to the other, publications may contain identifiers from both systems. Cross-references The British Standarch which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled

    7、 “International Standards Correspondence Index“, or by using the “Find“ facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance

    8、with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the IEC title page, pages 2 to 62, an inside back cover and a back cover. The BSI was lasi . ued. %:yright notice displayed in this docume

    9、nt indicates when the document O BSI 10-1999 ISBN O 580 32958 5 I I TECHNICAL REPORT IEC 61 O1 0=3=06l First edition 1999-02 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-061 : Conformity verification report for IEC 61010-2-061 , Particular requir

    10、ements for laboratory atomic spectrometers with thermal atomization and ionization Rgles de scurit pour appareils lectriques de mesurage, de rgulation et de laboratoire - Partie 3-061: Rapport de vrification de la conformit de la CE1 61010-2-061, Specifications particulires pour les spectromtres ato

    11、misation et ionisation thermales Reference number IEC 61010-3-061 11 999(E) 1 CONTENTS Page FOREWORD . 3 5 Conformity verification report IEC 61 O1 0-2-61 Clause 5 6 7 8 9 10 11 i2 13 14 15 16 Marking and documentation Protection against electric shock . Protection against mechanical hazards . Mecha

    12、nical resistance to shock. vibration and impact (AM 1 only) Mechanical resistance to shock and impact (AM 2) . Equipment temperature limits and protection against the spread of fire Resistance to heat Resistance to moisture and liquids (AM 1 only) Protection against hazards from fluids (AM 2) . Prot

    13、ection against radiation, including laser sources, and against sonic and ultrasonic pressure . Protection against liberated gases, explosion and implosion Components . Protection by interlocks . Measuring circuits . 10 16 24 25 26 27 27 29 30 32 33 33 Annex K Routine tests . 33 Tables 1 Documents at

    14、tached to this report . 7 2 Test equipment list . 8 3 List of components relied on for safety 9 Form A.1 to Form A.29 34 to 62 2 INTERNATIONAL ELECTROTECHNICAL COMMISSION Enquiry draft 6611 82lCDV SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - Report on v

    15、oting 66t2091RVC Part 3-061 : Conformity verification report for IEC 61 O1 0-2-061, Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization FOREWORD 1) lhe IEC (International Electrotechnical Commission) is a worldwide organization for standardization comp

    16、rising all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, the IEC publishes Internatio

    17、nal Standards. Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation.

    18、The IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an international conse

    19、nsus of opinion on the relevant subjects since each technical committee has representation from all interested National Committees. 3) lhe documents produced have the form of recommendations for international use and are published in the form of standards, technical reports or guides and they are ac

    20、cepted by the National Committees in that sense. 4) In order to promote international unification, IEC National Committees undertake to apply IEC International Standards transparently to the maximum extent possible in their national and regional standards. Any divergence between the IEC Standard and

    21、 the corresponding national or regional standard shall be clearly indicated in the latter. 5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with one of its standards. 6) Attention is drawn to the possi

    22、bility that some of the elements of this International Standard may be the subject of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights. The main task of IEC technical committees is to prepare International Standards. However, a technical committee ma

    23、y propose the publication of a technical report when it has collected data of a different kind from that which is normally published as an International Standard, for example “state of the art“. Technical reports do not necessarily have to be reviewed until the data they provide are considered to be

    24、 no longer valid or useful. IEC 61010-3-061, which is a technical report, has been prepared by IEC technical committee 66: Safety of measuring, control, and laboratory equipment. Full information on the voting for the approval of this technical report can be found in the report on voting indicated i

    25、n the above table. 3 STD=BSI BS IEC bLOLO-3-ObL-ENGL 1777 M lb211bb9 77bb5b Li50 BS IEC 61010-3-061:1999 This report is a Technical Report and is of a purely informative nature and is therefore by itself not to be regarded as an international Standard. It is for use by testhouses and other users to

    26、assist them with determining and recording verification of conformity of the equipment under test with the requirements of: IEC 61010-2-061:1995 and or IEC 61010-1:1990 + amendment 1:1992, IEC 61010-1:1990 + amendment 1:1992 + amendment 2:1995 The protocol for completion of this report is contained

    27、in publication IEC 61 O1 0-3: 1997. Requirements which apply only to amendment 2 to IEC 61010-1 are indicated by “(AM 2)“ in the first column. Requirements deleted by amendment 2 to IEC 61010-1 are indicated by “(AM 1 only)“ in the second column. The IEC sells read-only PDF files as a general rule.

    28、In the present instance, and quite exceptionally, to enable the user to fill in the forms, a revisable file is included in a pocket affixed to the back cover of this publication. This publication can be down-loaded from the Web as a PDF file. There is, however, at the end of the document, a revisabl

    29、e file containing the forms. Please use the ziphnzip function. 4 STD=BSI BS IEC bLULO-3-ObL-ENGL 1797 Lb24bb7 079bb57 377 W BS IEC 61010-3-061:1999 Conformity Verification Report Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-061 :1995, Particular

    30、requirements for laboratory atomic spectrometers with thermal atomization and ionization IEC 61 O1 0-2-061 : Report reference No . : Compiled by (+ signature) . : Approved by (+ signature) : Date of issue .: Testing organization .: Address .: Testing location . : Applicant .: Address . : I Standard

    31、. : IEC 61010-2-061:1995 and IEC 61010-1:1990 + A1:1992 orlEC 61010-1:1990 t A1:1992 + A2:1995 I Copyright blank test report . : This report has been prepared by IEC TC 66, which retains responsibility for any changes or corrections required. Test procedure .: Procedure deviation . : Non-standard te

    32、st method : Type of item tested .: Trade mark : Modetype reference . .: Manufacturer : Rating . : Copy of rating plate: Laboratory STDoBSI BS IEC bLULU-3-ObL-ENGL 31779 M lb29bb7 077bb58 223 I BS IEC 61010-3-061:1999 Description of equipment function . . : INSTALLATlON/OVERVOLTAGE CATEGORY . : POLLU

    33、TION DEGREE: Environmental rating: Standard Other (specify): Equipment mobility: Portable Hand-held Connection to mains supply: Permanent Detachable 3perating conditions: Continuous Short-time 3verall size of the equipment (length x width x height): Mass of the equipment (kg): Harked degree of prote

    34、ction to IEC 60529: IP- - Built in Benchmounted Floorstanding Other (specify): Non detachable Intermittent Fixed None kcessories and detachable parts included in the evaluation: lptions: JOTE - “(see Form A.X)“ refers to a Form appended to the report. 6 BS IEC 61010-3-061:1999 - Document No. Documen

    35、t description Number of pager Table 1 - Documents attached to this report 7 STD-BSI BS IEC bLOZO-3-ObL-ENGL 1979 E lb2qbb9 079bbb0 981 BS IEC 61010-3-061:1999 8 9 BS IEC 61010-3-061:1999 Requirement Clause Subclause 5 Result Comments 5.1.1 5.1.2 i.1.3 AM 2) F General Required equipment markings are:

    36、 a) visible: 3r ir ir - from the exterior - after removing a cover - opening a door - after removal from a rack or panel 3) not put on parts which can be removed :) Letter symbols (IEC 60027) used j) Graphic symbols (IEC 61010-1: table 1) used dentifkation Iquipment is identified by: - manufacturers

    37、 name or registered by an OPERATOR trade mark - model number, name or other means - the degree of protection, if any, according to IEC 60529 Mains supply Equipment is marked as follows: i) nature of supply: - a.c. RATED mains frequency or range of frequencies - d.c. with symbol 1 b) RATED supply vol

    38、tage(s) or range :) - maximum RA: -I aower (W or VA) or input current If more than one voltage range: - separate values marked - values differ by less than 20 % (see Form A.3) Ir Result: P = Pass F = Fail NA = Not Applicable 10 _ BS IEC 61010-3-061:1999 Requirement Result Clau- Subclauae Comments i.

    39、l.4 5.1.5 F (AM 2: - indicates the equipment set voltage - PORTABLE EQUIPMENT indication is visible from the exterior - changing the setting changes the indication F) Accessory mains socket-outlets accepting standard mains plugs are marked: - with the voltage if it is different from the mains supply

    40、 voltage - for use only with specific equipment f not marked for specific equipment it is narked with: - the maximum RATED current or power, and maximum permitted leakage current - symbol 14 with full details in the documentation The measured value not more than 1 1 O % :see Fom A.3) Fuses Ir PER AT

    41、 OR replaceable fuse marking I I (see also 5.4.5) Measuring circuit TERMINALS WTED maximurn working voltage or current I I marked Unless clear indication that below limits: - maximum RATED voltage to earth is marked Dr - for specific connection only, and means I I for identwing provided - iS adjacen

    42、t to TERMINALS or - if insufficient space: - on the RATING plate or scale plate or - if the TERMINAL is marked with symbol 14 Result: P = Pass F = Fail NA = Not Applicable 11 - STD.BS1 BS IEC b1010-3-0bl-ENGL 1999 lb2Llbb 079bbbq 527 W BS IEC 61010-3-061:1999 Requirement Clause Subclause (AM 2 Resul

    43、t Comments 5.1.6 5.1.7 5.1.8 TERMINALS permanently connected and I I not ACCESSIBLE TERMINALS and operating devices II Where necessary for safety, indication of purpose of TERMINALS, connectors, controls and indicators Mains supply TERMINALS identified Power supply switch on or off position marked I

    44、 I if used as disconnecting device TERMINAL marking: a) FUNCTIONAL EARTH TERMINALS b) PROTECTIVE CONDUCTOR TERMINALS: - symbol 6 is placed close to or on I I the TERMINAL or - part of appliance inlet c) TERMINALS of measuring and control circuits d) TERMINALS supplied from the intenor e) ACCESSIBLE

    45、NNCTIONAL EARTH TERMINALS f) Position on or off of Dower supply switch - (AM 1 only) Equipment protected by WUSLE iNsuunm or REINFORCED INSULATION Protected throughout (symbol 11 used) nly partially protected (symbol 11 not used) Battery charging Equipment with means to charge rechargeable batteries

    46、 is marked: - to warn against the charging of non- rechargeable batteries - to indicate the type of rechargeable battery used Result: P = Pass F = Fail NA = Not Applicable 12 BS IEC 61010-3-061:1999 Requirement Result Clause Subclause ,1.1 o1 Comments .2 I .3 i.4 i.4.1 :onnectors unambigiously marke

    47、d with: . identity of gas or liquid ind - maximum pressure Yarning markings visible when ready for NORMAL USE if necessary marked with symbol 1 are near or on applicable parts statement to isolate or disconnect advice how to avoid contact with ACCESSIBLE HAZARMXIS LIVE parts TERMINAL voltage exceedi

    48、ng 1 kV (symbol 12) easily touched high temperature parts I I (symbol 3) warning for more than 2 s (AM 1 only) Protective means against hot gases or plasma I I marked with symbol 13 Durability of markings The required markings remain clear and legible In NORMAL USE (See FOmi A.4) Documentation Gener

    49、al Equipment is accompanied by documentation which includes: - technical specification - instructions for use - name and address of manufacturer or supplier Definition Of INSTALLATION CATEGORY Warning statements and a clear explanation of warning symbols: - provided in the documentation or - information is marked on the equipment 1-1 Result: P = Pass F = Fail NA = Not Applicable 13 Clause Subclause 5.4.2 5.4.3 Comments Documentation includes: - supply voltage or voltage range - frequency or frequency range - power or current RATING - a de


    注意事项

    本文(BS IEC 61010-3-061-1999 Safety requirements for electrical equipment for measurement control and laboratory use - Conformity verification report for IEC 61010-2-061 particular requh.pdf)为本站会员(unhappyhay135)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!