欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    BS EN ISO 14937-2009 Sterilization of health care products - General requirements for characterization of a sterilizing agent and the development validation and routine control of .pdf

    • 资源ID:580813       资源大小:1.47MB        全文页数:52页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    BS EN ISO 14937-2009 Sterilization of health care products - General requirements for characterization of a sterilizing agent and the development validation and routine control of .pdf

    1、BS EN ISO14937:2009ICS 11.080.01NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDSterilization of healthcare products General requirementsfor characterizationof a sterilizing agentand the development,validation androutine control of asterilization processfor medi

    2、cal devices(ISO 14937:2009)Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 08/07/2010 03:49, Uncontrolled Copy, (c) BSIThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 31 March2010 BSI 2010ISBN 978 0 580 57850 2Amendments/corrigenda issued

    3、since publicationDate CommentsBS EN ISO 14937:2009National forewordThis British Standard is the UK implementation of EN ISO 14937:2009.It supersedes BS EN ISO 14937:2001 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee CH/198, Sterilization of medical de

    4、vices.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunityfr

    5、om legal obligations.Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 08/07/2010 03:49, Uncontrolled Copy, (c) BSIEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN ISO 14937 October 2009 ICS 11.080.01 Supersedes EN ISO 14937:2000English Version Sterilization of health care products - Genera

    6、l requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices (ISO 14937:2009) Strilisation des produits de sant - Exigences gnrales pour la caractrisation dun agent strilisant et pour la mise au point, l

    7、a validation et la vrification de routine dun processus de strilisation pour dispositifs mdicaux (ISO 14937:2009) Sterilisation von Produkten fr die Gesundheitsfrsorge - Allgemeine Anforderungen an die Charakterisierung eines sterilisierenden Agens und an die Entwicklung, Validierung und Lenkung der

    8、 Anwendung eines Sterilisationsverfahrens fr Medizinprodukte (ISO 14937:2009) This European Standard was approved by CEN on 24 September 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a na

    9、tional standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version i

    10、n any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark

    11、, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATIO

    12、N EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN ISO 14937:2009: ELicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 08/07/2010 03:49, Un

    13、controlled Copy, (c) BSIBS EN ISO 14937:2009EN ISO 14937:2009 (E) 3 Foreword This document (EN ISO 14937:2009) has been prepared by Technical Committee ISO/TC 198 “Sterilization of health care products“ in collaboration with Technical Committee CEN/TC 204 “Sterilization of medical devices” the secre

    14、tariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2010, and conflicting national standards shall be withdrawn at the latest by April 2010. Attention is drawn to

    15、 the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN ISO 14937:2000. This document has been prepared under a mandate given to CEN by

    16、 the European Commission and the European Free Trade Association, and supports essential requirements of EU Directives. For relationship with EU Directives, see informative Annex ZA, B and C, which are integral parts of this document. According to the CEN/CENELEC Internal Regulations, the national s

    17、tandards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland

    18、, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Endorsement notice The text of ISO 14937:2009 has been approved by CEN as a EN ISO 14937:2009 without any modification. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 08/07/2010 03:49, Uncontrolled Co

    19、py, (c) BSIBS EN ISO 14937:2009EN ISO 14937:2009 (E) 4 Annex ZA (informative) Relationship between this European Standard and the Essential Requirements of EU Directive 90/385/EEC on Active Implantable Medical Devices This European Standard has been prepared under a mandate given to CEN by the Europ

    20、ean Commission and the European Free Trade Association to provide a means of conforming to Essential Requirements of the New Approach Directive 90/385/EEC on active implantable medical devices. Once this standard is cited in the Official Journal of the European Union under that Directive and has bee

    21、n implemented as a national standard in at least one Member State, compliance with the clauses of this standard given in Table ZA.1 confers, within the limits of the scope of this standard, a presumption of conformity with the corresponding Essential Requirements of that Directive and associated EFT

    22、A regulations. Table ZA.1 Correspondence between this European Standard and Directive 90/385/EEC Clauses of this EN Essential Requirements (ERs) of Directive 90/385/EEC Qualifying remarks/Notes 4,5,6,7,8,9,10,11,12 7 This relevant Essential Requirement is only partly addressed in this European Stand

    23、ard WARNING Other requirements and other EU Directives may be applicable to the product(s) falling within the scope of this Standard. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 08/07/2010 03:49, Uncontrolled Copy, (c) BSIBS EN ISO 14937:2009EN ISO 14937:2009 (E) 5 Annex ZB (informative)

    24、Relationship between this European Standard and the Essential Requirements of EU Directive 93/42/EEC on Medical Devices This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association to provide a means of conforming to Essenti

    25、al Requirements of the New Approach Directive 93/42/EEC on medical devices. Once this standard is cited in the Official Journal of the European Union under that Directive and has been implemented as a national standard in at least one Member State, compliance with the clauses of this standard given

    26、in Table ZB.1 confers, within the limits of the scope of this standard, a presumption of conformity with the corresponding Essential Requirements of that Directive and associated EFTA regulations. Table ZB.1 Correspondence between this European Standard and Directive 93/42/EEC Clauses of this EN Ess

    27、ential Requirements (ERs) of Directive 93/42/EEC Qualifying remarks/Notes 4,5,6,7,8,9,10,11,12 8.3 This relevant Essential Requirement is only partly addressed in this European Standard 4,5,6,7,8,9,10,11,12 8.4 WARNING Other requirements and other EU Directives may be applicable to the product(s) fa

    28、lling within the scope of this Standard. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 08/07/2010 03:49, Uncontrolled Copy, (c) BSIBS EN ISO 14937:2009EN ISO 14937:2009 (E) 6 Annex ZC (informative) Relationship between this European Standard and the Essential Requirements of EU Directive 98

    29、/79/EC on in vitro diagnostic medical devices This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association to provide a means of conforming to Essential Requirements of the New Approach Directive 98/79/EC on in vitro diagnos

    30、tic medical devices. Once this standard is cited in the Official Journal of the European Union under that Directive and has been implemented as a national standard in at least one Member State, compliance with the clauses of this standard given in Table ZC.1 confers, within the limits of the scope o

    31、f this standard, a presumption of conformity with the corresponding Essential Requirements of that Directive and associated EFTA regulations. Table ZC.1 Correspondence between this European Standard and Directive 98/79/EC Clauses of this EN Essential Requirements (ERs) of Directive 98/79/EC Qualifyi

    32、ng remarks/Notes 4,5,6,7,8,9,10,11,12 2.3 This relevant Essential Requirement is only partly addressed in this European Standard 4,5,6,7,8,9,10,11,12 2.4 WARNING Other requirements and other EU Directives may be applicable to the product(s) falling within the scope of this Standard. Licensed Copy: W

    33、ang Bin, ISO/EXCHANGE CHINA STANDARDS, 08/07/2010 03:49, Uncontrolled Copy, (c) BSIBS EN ISO 14937:2009ISO 14937:2009(E) ISO 2009 All rights reserved iiiContents Page Foreword .v Introductionvi 1 Scope1 1.1 Inclusions.1 1.2 Exclusions1 2 Normative references2 3 Terms and definitions .2 4 Quality man

    34、agement system elements.7 4.1 Documentation 7 4.2 Management responsibility 7 4.3 Product realization 8 4.4 Measurement, analysis and improvement Control of non-conforming product8 5 Sterilizing agent characterization 8 5.1 General .8 5.2 Sterilizing agent.8 5.3 Microbicidal effectiveness8 5.4 Effec

    35、ts on materials 9 5.5 Safety and the environment .9 6 Process and equipment characterization .9 6.1 General .9 6.2 Process characterization9 6.3 Equipment characterization .10 7 Product definition10 8 Process definition .11 9 Validation12 9.1 General .12 9.2 Installation qualification .12 9.3 Operat

    36、ional qualification 13 9.4 Performance qualification 13 9.5 Review and approval of validation 14 10 Routine monitoring and control.14 11 Product release from sterilization .14 12 Maintaining process effectiveness15 12.1 General .15 12.2 Recalibration15 12.3 Maintenance of equipment .15 12.4 Requalif

    37、ication.15 12.5 Assessment of change .15 Annex A (normative) Factors to be considered in selection of microorganisms for demonstrating microbicidal effectiveness16 Annex B (normative) Approach 1 Process definition based on inactivation of the microbial population in its natural state 18 Annex C (nor

    38、mative) Approach 2 Process definition based on inactivation of reference microorganisms and knowledge of bioburden 19 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 08/07/2010 03:49, Uncontrolled Copy, (c) BSIBS EN ISO 14937:2009ISO 14937:2009(E) iv ISO 2009 All rights reservedAnnex D (norma

    39、tive) Approach 3 Conservative process definition based on inactivation of reference microorganisms20 Annex E (informative) Guidance on application of this International Standard .22 Bibliography 36 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 08/07/2010 03:49, Uncontrolled Copy, (c) BSIBS

    40、EN ISO 14937:2009ISO 14937:2009(E) ISO 2009 All rights reserved vForeword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical c

    41、ommittees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with t

    42、he International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft Internat

    43、ional Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be

    44、 the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 14937 was prepared by Technical Committee ISO/TC 198, Sterilization of health care products. This second edition cancels and replaces the first edition (ISO 14937:2000) and ISO 14937:2

    45、000/Cor.1:2003 which have been technically revised. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 08/07/2010 03:49, Uncontrolled Copy, (c) BSIBS EN ISO 14937:2009ISO 14937:2009(E) vi ISO 2009 All rights reservedIntroduction A sterile medical device is one that is free of viable microorganis

    46、ms. International Standards that specify requirements for validation and routine control of sterilization processes require, when it is necessary to supply a sterile medical device, that adventitious microbiological contamination of a medical device prior to sterilization be minimized. Even so, medi

    47、cal devices produced under standard manufacturing conditions in accordance with the requirements for quality management systems (see, for example, ISO 13485) could, prior to sterilization, have microorganisms on them, albeit in low numbers. Such medical devices are non-sterile. The purpose of steril

    48、ization is to inactivate the microbiological contaminants and thereby transform the non-sterile medical devices into sterile ones. The kinetics of inactivation of a pure culture of microorganisms by physical and/or chemical agents used to sterilize medical devices generally can best be described by

    49、an exponential relationship between the number of microorganisms surviving and the extent of treatment with the sterilizing agent; inevitably this means that there is always a finite probability that a microorganism might survive regardless of the extent of treatment applied. For a given treatment, the probability of survival is determined by the number and resistance of microorganisms and by the environment in which the organisms exist during treatment. It follows that the sterility of any one medical device in a population subject


    注意事项

    本文(BS EN ISO 14937-2009 Sterilization of health care products - General requirements for characterization of a sterilizing agent and the development validation and routine control of .pdf)为本站会员(wealthynice100)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!