欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    BS EN ISO 389-9-2009 Acoustics - Reference zero for the calibration of audiometric equipment - Preferred test conditions for the determination of reference hearing threshold levels.pdf

    • 资源ID:579284       资源大小:684.23KB        全文页数:16页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    BS EN ISO 389-9-2009 Acoustics - Reference zero for the calibration of audiometric equipment - Preferred test conditions for the determination of reference hearing threshold levels.pdf

    1、BS EN ISO389-9:2009ICS 13.140NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDAcoustics Referencezero for the calibrationof audiometricequipmentPart 9: Preferred test conditions forthe determination of reference hearingthreshold levels (ISO 389-9:2009)Licensed Co

    2、py: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2010 08:24, Uncontrolled Copy, (c) BSIThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 28 February2010 BSI 2010ISBN 978 0 580 70520 5Amendments/corrigenda issued since publicationDate CommentsBS EN

    3、 ISO 389-9:2009National forewordThis British Standard is the UK implementation of EN ISO 389-9:2009.The UK participation in its preparation was entrusted to TechnicalCommittee EH/1/1, Hearing.A list of organizations represented on this committee can be obtained onrequest to its secretary.This public

    4、ation does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2010 08:24, Uncontrolled Copy, (

    5、c) BSIEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN ISO 389-9May 2009ICS 13.140English VersionAcoustics - Reference zero for the calibration of audiometricequipment - Part 9: Preferred test conditions for thedetermination of reference hearing threshold levels (ISO 389-9:2009)Acoustique - Zro de

    6、rfrence pour ltalonnagedquipements audiomtriques - Partie 9: Conditionsdessai prconises pour la dtermination des niveauxliminaires daudition de rfrence (ISO 389-9:2009)Akustik - Standard-Bezugspegel fr die Kalibrierungaudiometrischer Gerte - Teil 9: Vorzugs-Messbedingungen zur Bestimmung von Bezugs-

    7、Hrschwellenpegeln (ISO 389-9:2009)This European Standard was approved by CEN on 30 April 2009.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date

    8、 lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the re

    9、sponsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Ic

    10、eland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: Avenue Ma

    11、rnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN ISO 389-9:2009: ELicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2010 08:24, Uncontrolled Copy, (c) BSIBS EN ISO 389-9:2009EN ISO 389-9:2009 (

    12、E) 3 Foreword This document (EN ISO 389-9:2009) has been prepared by Technical Committee ISO/TC 43 “Acoustics“ in collaboration with Technical Committee CEN/TC 211 “Acoustics”, the secretariat of which is held by DS. This European Standard shall be given the status of a national standard, either by

    13、publication of an identical text or by endorsement, at the latest by November 2009, and conflicting national standards shall be withdrawn at the latest by November 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or C

    14、ENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, De

    15、nmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Endorsement notice The text of ISO 389-9:2009 has been appr

    16、oved by CEN as a EN ISO 389-9:2009 without any modification. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2010 08:24, Uncontrolled Copy, (c) BSIBS EN ISO 389-9:2009ISO 389-9:2009(E) ISO 2009 All rights reserved iiiForeword ISO (the International Organization for Standardization) is a

    17、 worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represente

    18、d on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are draf

    19、ted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Sta

    20、ndard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 389-9 was prepared

    21、by Technical Committee ISO/TC 43, Acoustics. ISO 389 consists of the following parts, under the general title Acoustics Reference zero for the calibration of audiometric equipment: Part 1: Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones Part 2: Reference

    22、 equivalent threshold sound pressure levels for pure tones and insert earphones Part 3: Reference equivalent threshold force levels for pure tones and bone vibrators Part 4: Reference levels for narrow-band masking noise Part 5: Reference equivalent threshold sound pressure levels for pure tones in

    23、the frequency range 8 kHz to 16 kHz Part 6: Reference threshold of hearing for test signals of short duration Part 7: Reference threshold of hearing under free-field and diffuse-field listening conditions Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural ear

    24、phones Part 9: Preferred test conditions for the determination of reference hearing threshold levels Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2010 08:24, Uncontrolled Copy, (c) BSIBS EN ISO 389-9:2009ISO 389-9:2009(E) iv ISO 2009 All rights reservedIntroduction ISO/TC 43, Acousti

    25、cs, is responsible for the production of International Standards specifying human hearing thresholds for use in the calibration of audiometric equipment. The Committee bases its work on data from independent laboratories throughout the world. Unfortunately, problems have existed in the past in tryin

    26、g to relate the data from experiments carried out by different laboratories in different parts of the world, all of which have had the same objective, but which lacked a common set of criteria for subject selection, methods of test and reporting of data, etc. ISO/TC 43 has developed this part of ISO

    27、 389 in order to collate the data that is being, or will be, produced in the future, and to encourage other laboratories to participate in these activities. The test conditions are aimed at providing guidance to researchers to ensure that the collation of future work is made easier, which in turn ou

    28、ght to lead to a more rapid production of relevant standards. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2010 08:24, Uncontrolled Copy, (c) BSIBS EN ISO 389-9:2009INTERNATIONAL STANDARD ISO 389-9:2009(E) ISO 2009 All rights reserved 1Acoustics Reference zero for the calibration of

    29、audiometric equipment Part 9: Preferred test conditions for the determination of reference hearing threshold levels 1 Scope This part of ISO 389 specifies test conditions for determining the hearing thresholds of subjects for the purpose of establishing standardized values for reference hearing thre

    30、shold levels. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including amendments) applies. ISO 389-1:1998,

    31、Acoustics Reference zero for the calibration of audiometric equipment Part 1: Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones1)ISO 389-2, Acoustics Reference zero for the calibration of audiometric equipment Part 2: Reference equivalent threshold sound p

    32、ressure levels for pure tones and insert earphones1)ISO 389-3, Acoustics Reference zero for the calibration of audiometric equipment Part 3: Reference equivalent threshold force levels for pure tones and bone vibrators ISO 389-6, Acoustics Reference zero for the calibration of audiometric equipment

    33、Part 6: Reference threshold of hearing for test signals of short duration ISO 389-7, Acoustics Reference zero for the calibration of audiometric equipment Part 7: Reference threshold of hearing under free-field and diffuse-field listening conditions ISO 389-8, Acoustics Reference zero for the calibr

    34、ation of audiometric equipment Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural earphones ISO 8253-1:2), Acoustics Audiometric test methods Part 1: Basic pure-tone air and bone conduction threshold audiometry ISO 8253-2:3), Acoustics Audiometric test method

    35、s Part 2: Sound field audiometry with pure tone and narrow-band test signals 1) Under revision. 2) To be published. (Revision of ISO 8253-1:1989) 3) To be published. (Revision of ISO 8253-2:1992) Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2010 08:24, Uncontrolled Copy, (c) BSIBS EN

    36、 ISO 389-9:2009ISO 389-9:2009(E) 2 ISO 2009 All rights reservedISO/IEC Guide 98-3, Uncertainty of measurement Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) IEC 60318-1, Electroacoustics Simulators of human head and ear Part 1: Ear simulator for the calibration of supra-aur

    37、al and circumaural earphones 4)IEC 60318-3, Electroacoustics Simulators of human head and ear Part 3: Acoustic coupler for the calibration of supra-aural earphones used in audiometry IEC 60318-4, Electroacoustics Simulators of human head and ear Part 4: Occluded-ear simulator for the measurement of

    38、earphones coupled to the ear by ear inserts 5)IEC 60318-5, Electroacoustics Simulators of human head and ear Part 5: 2 cm3coupler for the measurement of hearing aids and earphones coupled to the ear by means of ear inserts IEC 60318-6, Electroacoustics Simulators of human head and ear Part 6: Mechan

    39、ical coupler for the measurement of bone vibrators IEC 60645-1:2001, Electroacoustics Audiological equipment Part 1: Pure-tone audiometers IEC 60645-3:2007, Electroacoustics Audiometric equipment Part 3: Test signals of short duration IEC 60645-4, Audiometers Part 4: Equipment for extended high-freq

    40、uency audiometry 3 Terms and definitions For the purposes of this document, the terms and definitions given in ISO 8253-1 and ISO 389-6 apply. 4 Test conditions 4.1 Test subjects 4.1.1 At least 25 subjects shall participate, both males and females, preferably represented in equal numbers. 4.1.2 The

    41、subjects shall be in the age range 18 years to 25 years inclusive. 4.1.3 The subjects shall be otologically normal, i.e. be in a normal state of health, be free from all signs or symptoms of ear disease and from obstructing wax in the ear canals, and have no history of undue exposure to noise, expos

    42、ure to potentially ototoxic drugs or familial hearing loss. Minimum information to be collected is given in Annex A. 4.1.4 Tympanometry shall be performed at the beginning of each test session. Hearing threshold measurements shall be performed only if a middle ear pressure in the range 50 daPa has b

    43、een obtained. 4.2 Maximum ambient noise levels 4.2.1 The acoustic environment in which the test subjects are located during testing shall fulfil the requirements given in ISO 8253-1:, 11.1 and 11.2 for measurement of hearing levels down to 10 dB with a maximum uncertainty of +2 dB due to ambient noi

    44、se. The requirements for 8 kHz shall also be applied to the one-third-octave bands from 10 kHz to 16 kHz. 4) To be published. (Revision of IEC 60318-1:1998 and IEC 60318-2:1998) 5) To be published. (Revision of IEC 60711:1981) Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2010 08:24,

    45、Uncontrolled Copy, (c) BSIBS EN ISO 389-9:2009ISO 389-9:2009(E) ISO 2009 All rights reserved 34.2.2 For typical current supra-aural earphones with sound attenuation as given in ISO 8253-1:, Table 3, conformance with the requirement of 4.2.1 means that noise levels shall be at least 10 dB below the l

    46、evels given in ISO 8253-1:, Table 2. 4.2.3 If the sound attenuation provided by the actual earphone differs from the values given in ISO 8253-1:, Table 3, the maximum permissible level of noise shall be modified accordingly. 4.2.4 For sound field audiometry, the acoustic environment shall fulfil the

    47、 requirement given in ISO 8253-2:, Clause 6. 4.3 Test procedure Monaural pure-tone hearing threshold levels shall be determined according to ISO 8253-1. Binaural hearing threshold levels shall be determined according to ISO 8253-2. Either the bracketing or ascending method shall be used. Each subjec

    48、t shall have at least one training session with two or three selected test signals. 5 Audiometric equipment 5.1 General The audiometric equipment, which is used for control of stimulus gating and stimulus level and for execution of the test procedure, shall fulfill the relevant requirements of IEC 6

    49、0645-1 (for air- and bone-conduction pure-tone signals and masking), IEC 60645-3 (only for signals of short duration) and IEC 60645-4 (only for extended high-frequency signals). Special care shall be taken to avoid detection by the test subjects of any sounds coinciding with the tone and attenuator switching. Calibration of test equipment shall be performed at regular intervals to ensure that levels are within those specified in the prevailing data.


    注意事项

    本文(BS EN ISO 389-9-2009 Acoustics - Reference zero for the calibration of audiometric equipment - Preferred test conditions for the determination of reference hearing threshold levels.pdf)为本站会员(cleanass300)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开