欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    BS EN 61010-2-061-2015 Safety requirements for electrical equipment for measurement control and laboratory use Particular requirements for laboratory atomic spectrometers with ther.pdf

    • 资源ID:576710       资源大小:1.17MB        全文页数:22页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    BS EN 61010-2-061-2015 Safety requirements for electrical equipment for measurement control and laboratory use Particular requirements for laboratory atomic spectrometers with ther.pdf

    1、BSI Standards PublicationSafety requirements for electrical equipment for measurement, control and laboratory usePart 2-061: Particular requirements for laboratory atomic spectrometers with thermal atomization and ionizationBS EN 61010-2-061:2015National forewordThis British Standard is the UK imple

    2、mentation of EN 61010-2-061:2015. It is identical to IEC 61010-2-061:2015. It supersedes BS EN 61010-2-061:2003,which will be withdrawn on 14 April 2018.The UK participation in its preparation was entrusted to TechnicalCommittee EPL/66, Safety of measuring, control and laboratory equipment.A list of

    3、 organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited

    4、 2015ISBN 978 0 580 79880 1ICS 19.080; 71.040.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 May 2015.Amendments/corrigenda issued since publicationDate Text

    5、 affectedBRITISH STANDARDBS EN 61010-2-061:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 61010-2-061 April 2015 ICS 19.080; 71.040.20 Supersedes EN 61010-2-061:2003 English Version Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-061: Parti

    6、cular requirements for laboratory atomic spectrometers with thermal atomization and ionization (IEC 61010-2-061:2015) Rgles de scurit pour appareils lectriques de mesurage, de rgulation et de laboratoire - Partie 2-061: Exigences particulires pour spectromtres atomiques de laboratoire avec vaporisat

    7、ion et ionisation thermiques (IEC 61010-2-061:2015) Sicherheitsbestimmungen fr elektrische Mess-, Steuer-, Regel- und Laborgerte - Teil 2-061: Besondere Anforderungen an Labor-Atomspektrometer mit thermischer Atomisierung und Ionisation (IEC 61010-2-061:2015) This European Standard was approved by C

    8、ENELEC on 2015-04-14. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national stan

    9、dards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own langua

    10、ge and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France

    11、, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Norma

    12、lisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 61010-2-061:2015 E BS EN 61010-2-061:20

    13、15EN 61010-2-061:2015 - 2 - Foreword The text of document 66/553/FDIS, future edition 3 of IEC 61010-2-061, prepared by IEC/TC 66 “Safety of measuring, control and laboratory equipment“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61010-2-061:2015. The following dates

    14、 are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2016-01-14 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2018-04-14 This document supe

    15、rsedes EN 61010-2-061:2003. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. This standard covers the Principle Elements of the Safety

    16、Objectives for Electrical Equipment Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC). Endorsement notice The text of the International Standard IEC 61010-2-061:2015 was approved by CENELEC as a European Standard without any modification. BS EN 61010-2-061:2015- 3 - EN 61010-2-061:20

    17、15 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited

    18、applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions

    19、of the European Standards listed in this annex is available here: www.cenelec.eu. Annex ZA of Part 1 applies. BS EN 61010-2-061:2015 2 IEC 61010-2-061:2015 IEC 2015 CONTENTS FOREWORD . 3 1 Scope and object . 5 2 Normative references 5 3 Terms and Definitions 5 4 Tests . 6 5 Marking and documentation

    20、 . 6 6 Protection against electric shock . 9 7 Protection against mechanical hazards 9 8 Resistance to mechanical stresses . 9 9 Protection against the spread of fire 10 10 Equipment temperature limits and resistance to heat . 10 11 Protection against HAZARDS from fluids 10 12 Protection against rad

    21、iation, including laser sources, and against sonic and ultrasonic pressure 11 13 Protection against liberated gases and substances, explosion and implosion 11 14 Components and subassemblies . 13 15 Protection by interlocks . 13 16 HAZARDS resulting from application 14 17 RISK Assessment . 14 Annexe

    22、s . 15 Annex F (normative) Routine tests . 15 Annex H (informative) Index of defined terms . 15 Bibliography 15 Figure 101 Example of a GAS LOCK . 12 Table 101 Time-temperature conditions . 9 BS EN 61010-2-061:2015IEC 61010-2-061:2015 IEC 2015 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ SAFETY REQ

    23、UIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE Part 2-061: Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardizat

    24、ion comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes Internatio

    25、nal Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in t

    26、his preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the tw

    27、o organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have th

    28、e form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinter

    29、pretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national

    30、or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carri

    31、ed out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Comm

    32、ittees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn t

    33、o the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be

    34、held responsible for identifying any or all such patent rights. International Standard IEC 61010-2-061 has been prepared by IEC technical committee 66: Safety of measuring, control and laboratory equipment. It has the status of a group safety publication in accordance with IEC Guide 104. This third

    35、edition cancels and replaces the second edition published in 2003. It constitutes a technical revision and includes the following change from the second edition: exclusion of equipment, whose size and weight make unintentional movement unlikely, from the drop test in Clause 8. notes have been re-phr

    36、ased according to ISO/IEC Directives. BS EN 61010-2-061:2015 4 IEC 61010-2-061:2015 IEC 2015 The text of this standard is based on the following documents: FDIS Report on voting 66/553/FDIS 66/568/RVD Full information on the voting for the approval of this standard can be found in the report on voti

    37、ng indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. A list of all parts of the IEC 61010 series, under the general title: Safety requirements for electrical equipment for measurement, control, and laboratory use, may be found on the I

    38、EC website. This Part 2-061 is intended to be used in conjunction with IEC 61010-1. It was established on the basis of the third edition (2010). This Part 2-061 supplements or modifies the corresponding clauses in IEC 61010-1 so as to convert that publication into the IEC standard: Safety requiremen

    39、ts for laboratory atomic spectrometers with thermal atomization and ionization. Where a particular subclause of Part 1 is not mentioned in this part 2, that subclause applies as far as is reasonable. Where this part states “addition”, “modification” or “replacement”, or “deletion”, the relevant requ

    40、irement, test specification or note in Part 1 should be adapted accordingly. In this standard: 1) the following print types are used: requirements: in roman type; NOTES: in small roman type; conformity and test: in italic type; terms used throughout this standard which have been defined in clause 3:

    41、 SMALL ROMAN CAPITALS; 2) subclauses, figures, tables and notes which are additional to those in Part 1 are numbered starting from 101. The additional annexes are lettered starting from AA. The committee has decided that the contents of this publication will remain unchanged until the stability date

    42、 indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. BS EN 61010-2-061:2015IEC 61010-2-061:2015 IEC 2015 5 SAFETY REQUIREMENTS FOR ELECTRI

    43、CAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE Part 2-061: Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization 1 Scope and object This clause of Part 1 is applicable except as follows: 1.1 Scope 1.1.1 Equipment included in scope Replacement

    44、: Replace the text by the following: This part of IEC 61010 applies to electrically powered laboratory atomic spectrometers with thermal atomization. NOTE 1 Examples include atomic absorption spectrometers, emission flame photometers, atomic fluorescence spectrophotometers, inductively coupled plasm

    45、a spectrometers, microwave coupled plasma spectrometers and mass spectrometers, all with thermal atomization and ionization (including tubing and connectors which are provided by the manufacturer for connection to external supplies). NOTE 2 If all or part of the equipment falls within the scope of o

    46、ne or more other part 2 standards of IEC 61010 as well as within the scope of this standard, consideration is to be given to those other part 2 standards. 1.1.2 Equipment excluded from scope Addition: Add as the first paragraph: This standard does not apply to thermal atomization detectors (flame io

    47、nization detectors) used in gas chromatography. 2 Normative references This clause of Part 1 is applicable. 3 Terms and Definitions This clause of Part 1 is applicable except as follows: Additions: Add the following definitions: 3.2.101 SPRAY CHAMBER chamber in which droplets of sample in aerosol ar

    48、e allowed to separate so that the droplets of necessary size can be passed onward to the burner, with the remainder draining to waste BS EN 61010-2-061:2015 6 IEC 61010-2-061:2015 IEC 2015 3.2.102 GAS LOCK device to allow drainage of waste sample liquid, and to prevent unintentional escape of gas fr

    49、om the SPRAY CHAMBER through its drain outlet Note 1 to entry: See for example Figure 101. 3.5.101 FLASH-BACK event during which the flame travels back through the burner with the result that the gas in the mixing chamber is caused to ignite. 4 Tests This clause of Part 1 is applicable except as follows: Addition: Add the following subclauses: 4.4.2.101 Sampling probe tip Any system designed to withdraw a sampling probe tip after sampling has been completed shall be overridden, so as to l


    注意事项

    本文(BS EN 61010-2-061-2015 Safety requirements for electrical equipment for measurement control and laboratory use Particular requirements for laboratory atomic spectrometers with ther.pdf)为本站会员(brainfellow396)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开