    BS EN 13472-2012 Thermal insulating products for building equipment and industrial installations Determination of short term water absorption by partial immersion of preformed pipe.pdf

    • 资源ID:571524       资源大小:1.02MB        全文页数:18页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    BS EN 13472-2012 Thermal insulating products for building equipment and industrial installations Determination of short term water absorption by partial immersion of preformed pipe.pdf

    1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 13472:2012Thermal insulating productsfor building equipment andindustrial installations Determination of short termwater absorption by partialimmersion of preformed pipeins

    2、ulationCopyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 13472:2012 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 13472:2012. Itsupers

    3、edes BS EN 13472:2001 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee B/540, Energy performance of materials components andbuildings.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does n

    4、ot purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2013. Published by BSI StandardsLimited 2013ISBN 978 0 580 77438 6ICS 91.100.60Compliance with a British Standard cannot confer immunity fromlegal obli

    5、gations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 January 2013.Amendments issued since publicationDate Text affectedCopyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction o

    6、r networking permitted without license from IHS-,-,-BS EN 13472:2012EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13472 October 2012 ICS 91.100.60 Supersedes EN 13472:2001English Version Thermal insulating products for building equipment and industrial installations - Determination of short t

    7、erm water absorption by partial immersion of preformed pipe insulation Produits isolants thermiques pour lquipement du btiment et les installations industrielles - Dtermination de labsorption deau court terme par immersion partielle des coquilles isolantes prformes Wrmedmmstoffe fr die Haustechnik u

    8、nd fr betriebstechnische Anlagen - Bestimmung der Wasseraufnahme bei kurzzeitigem teilweisem Eintauchen von vorgeformten Rohrdmmstoffen This European Standard was approved by CEN on 24 August 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditio

    9、ns for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in

    10、 three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standard

    11、s bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Sloven

    12、ia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for

    13、 CEN national Members. Ref. No. EN 13472:2012: ECopyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 13472:2012EN 13472:2012 (E) 2 Contents Page Foreword 31 Scope 42 Normative r

    14、eferences 43 Terms and definitions .44 Principle 45 Apparatus .46 Test specimens 66.1 Dimensions of test specimens .66.2 Preparation of test specimens .66.3 Number of test specimens 66.4 Conditioning of test specimens .77 Procedure .77.1 Test conditions 77.2 Test procedure .77.2.1 General 77.2.2 Met

    15、hod A (drainage) 77.2.3 Method B (deduction of initial water uptake) 78 Calculation and expression of results .89 Accuracy of measurement 910 Test report 9Annex A (informative) Table with examples of calculation of the length of test specimens . 10Bibliography . 13Tables Table A.1 Examples of calcul

    16、ation of the length of test specimens 10Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 13472:2012EN 13472:2012 (E) 3 Foreword This document (EN 13472:2012) has been prepar

    17、ed by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2013, and conflictin

    18、g national standards shall be withdrawn at the latest by April 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document sup

    19、ersedes EN 13472:2001. The following main technical changes have been done on this new edition of EN 13472: a) Figure 1 has been corrected; b) Subclause 5.3, Tap water has been supplemented. This European Standard has been prepared for products used to insulate building equipment and industrial inst

    20、allations, but it may also be applied to products used in other areas. This European Standard is one of a series of standards which specify test methods for determining dimensions and properties of thermal insulating materials and products. It supports a series of product standards for thermal insul

    21、ating materials and products which derive from the Council Directive of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products (Directive 89/106/EEC) through the consideration of the essential requirements. Acco

    22、rding to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany

    23、, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Copyright European Committee for Standardization Provided by IHS under license with CENNot

    24、for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 13472:2012EN 13472:2012 (E) 4 1 Scope This European Standard specifies the equipment and procedures for determining the short term water absorption of preformed pipe insulation by partial immersion in water. It is a

    25、pplicable to thermal insulating products. NOTE It is intended to simulate the water absorption caused by exposure to rain for 24 h during product installation. If the pipe insulation is cut from a flat product, then the short term water absorption by partial immersion can be obtained from tests carr

    26、ied out on the flat product with similar properties in accordance with EN 1609, providing the test is carried out in the direction giving the highest water uptake. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable f

    27、or its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 13467, Thermal insulating products for building equipment and industrial installations Determination of dimensions, s

    28、quareness and linearity of preformed pipe insulation 3 Terms and definitions This European Standard contains no terms and definitions. 4 Principle The short term water absorption by partial immersion is determined by measuring the change in mass of a test specimen, the lower part of which is in cont

    29、act with water for a period of 24 h. The excess water adhering to the surface and not absorbed by the test specimen is drained off in method A, or calculated in method B, from the initial water uptake. 5 Apparatus 5.1 Balance capable of determining the mass of a test specimen to an accuracy of 0,1 g

    30、 or 0,5 %, whichever is less. 5.2 Water tank with a device for keeping the water level constant to within 2 mm, and a device to keep the test specimen in the required position during the test (see examples in Figures 1a) and 1b). The supporting device shall be such that the test specimen contact are

    31、a with water shall be at least 85 % and such that the original form of the test specimen is maintained. 5.3 Tap water adjusted to a temperature of (23 5) C. In case of dispute, deionised water shall be used. 5.4 Equipment for drainage (see examples in Figures 2a) and 2b). Copyright European Committe

    32、e for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 13472:2012EN 13472:2012 (E) 5 Dimensions in millimetres a) Example for D0 300 mm b) Example for D0 300 mm Key 1 water tank 2 load to keep the test spec

    33、imen in position 3 stainless steel mesh 4 test specimen Figure 1 Examples of partial immersion test devices Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 13472:2012EN 134

    34、72:2012 (E) 6 a) b)Key 1 stainless steel mesh 2 test specimen 3 perforated stainless steel Figure 2 Examples of equipment for drainage 6 Test specimens 6.1 Dimensions of test specimens Test specimens shall be prepared from the product without reducing the original thickness. In the event that the ou

    35、tside diameter of the product is 300 mm, the test specimen shall have one face with an area equal to the full cross sectional area of the product or half the original cross sectional area. For products with outside diameters 300 mm, the face shall be a segment of the cross section with an outside ch

    36、ord length of (300 10) mm. The length of the test specimen shall be adjusted so that the area of the immersed cylindrical surface will be (40 000 400) mm. 6.2 Preparation of test specimens The test specimens shall be cut so that they do not include product ends. The test specimens shall be prepared

    37、by methods that do not change the original structure of the product. Any skins, facings and/or coatings shall be retained. NOTE Special methods of preparation, when needed, are specified in the relevant product standard. For products with a thickness 25 mm, the ends shall be closed to avoid water pi

    38、ckup on the inner main surface of the test specimen (e.g. by use of glued aluminium foil on the ends). 6.3 Number of test specimens The number of test specimens shall be as specified in the relevant product standard. If the number is not specified, then at least three test specimens shall be used. I

    39、n the absence of a product standard or any other European Technical Specification, the number of test specimens may be agreed between parties. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license

    40、from IHS-,-,-BS EN 13472:2012EN 13472:2012 (E) 7 6.4 Conditioning of test specimens The test specimens shall be stored for at least 6 h at (23 5) C. In case of dispute, they shall be stored at (23 2) C and (50 5) % relative humidity for the time specified in the relevant product standard. 7 Procedur

    41、e 7.1 Test conditions The test shall be carried out at (23 5) C. In case of dispute it shall be carried out at (23 2) C and (50 5) % relative humidity. 7.2 Test procedure 7.2.1 General The choice of the method A or B shall be as specified in the relevant product standard. In the absence of a product

    42、 standard or any other European Technical Specification, the method A or B may be agreed between parties. The dimensions of the test specimens shall be measured in accordance with EN 13467. 7.2.2 Method A (drainage) Weigh the test specimen to the nearest 0,1 g or 0,5 %, whichever is less, to determi

    43、ne its initial mass m0. Place the test specimen with the outside surface downwards in the empty water tank and apply a sufficient load to keep the test specimen partially immersed when water is added. Carefully adjust the water added to the tank until the lowest point of the outside face of the test

    44、 specimen is (20 2) mm below the surface of the water (see examples in Figures 1a) and 1b). Ensure that the water level remains constant during the test. Remove the test specimen after 24 h and drain it for (10 0,5) min by placing it supported on the exterior surface on a mesh, inclined at 45, as sh

    45、own in Figure 2a) or 2b). Weigh the test specimen again to determine the mass m24. 7.2.3 Method B (deduction of initial water uptake) Weigh the test specimen to the nearest 0,1 g or 0,5 %, whichever is less, to determine its initial mass m0. Place the test specimen with the outside surface downwards

    46、 in the water tank in such position that it is partially immersed in water with the lowest point of the outside face of the test specimen (20 2) mm below the water level. Remove the test specimen after 10 s holding it horizontally and place it within 5 s in a plastic tray of known mass. Reweigh this

    47、 tray with the test specimen to determine the mass of the test specimen including the initial water uptake m1. Replace the test specimen in the water tank in the same position and apply a sufficient load to keep the test specimen partially immersed in water, with the lowest point of the outside face

    48、 of the test specimen (20 2) mm below the water level (see examples in Figures 1a) and 1b). Ensure that the water level remains constant during the test. Remove the test specimen after 24 h, holding it horizontally and place it within 5 s in the plastic tray of known mass to determine the mass m24. Method B is only applicable if the initial water uptake is: Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-


    注意事项

    本文(BS EN 13472-2012 Thermal insulating products for building equipment and industrial installations Determination of short term water absorption by partial immersion of preformed pipe.pdf)为本站会员(arrownail386)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!