欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    BS EN 1279-1-2004 Glass in building - Insulating glass units - Generalities dimensional tolerances and rules for the system description《建筑物用玻璃 绝缘玻璃部件 系统描述的概要、尺寸公差和规则》.pdf

    • 资源ID:548814       资源大小:445.38KB        全文页数:28页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    BS EN 1279-1-2004 Glass in building - Insulating glass units - Generalities dimensional tolerances and rules for the system description《建筑物用玻璃 绝缘玻璃部件 系统描述的概要、尺寸公差和规则》.pdf

    1、BRITISH STANDARD BS EN 1279-1:2004 Glass in building Insulating glass units Part 1: Generalities, dimensional tolerances and rules for the system description The European Standard EN 1279-1:2004 has the status of a British Standard ICS 81.040.20 BS EN 1279-1:2004 This British Standard was published

    2、under the authority of the Standards Policy and Strategy Committee on 16 June 2004 BSI 16 June 2004 ISBN 0 580 43944 5 National foreword This British Standard is the official English language version of EN 1279-1:2004. The UK participation in its preparation was entrusted by Technical Committee B/52

    3、0, Glass and glazing in building, to Subcommittee B/520/2, Insulating glass products, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or Europea

    4、n publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all

    5、the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on

    6、the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 24, an inside back cove

    7、r and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEANSTANDARD NORMEEUROPENNE EUROPISCHENORM EN12791 June2004 ICS81.040.20 Englishversion GlassinBuildingInsulatingglassuni

    8、tsPart1:Generalities, dimensionaltolerancesandrulesforthesystemdescription VerredanslaconstructionVitrageisolantprfabriquet scellPartie1:Gnralits,tolrancesdimensionnelles etrglesdedescriptiondusystme GlasimBauwesenMehrscheibenIsolierglasTeil1: Allgemeines,MatoleranzenundVorschriftenfrdie Systembesch

    9、reibung ThisEuropeanStandardwasapprovedbyCENon2January2003. CENmembersareboundtocomplywiththeCEN/CENELECInternalRegulationswhichstipulatetheconditionsforgivingthisEurope an Standardthestatusofanationalstandardwithoutanyalteration.Uptodatelistsandbibliographicalreferencesconcernings uchnational stand

    10、ardsmaybeobtainedonapplicationtotheCentralSecretariatortoanyCENmember. ThisEuropeanStandardexistsinthreeofficialversions(English,French,German).Aversioninanyotherlanguagemadebytra nslation undertheresponsibilityofaCENmemberintoitsownlanguageandnotifiedtotheCentralSecretariathasthesamestatusast heoff

    11、icial versions. CENmembersarethenationalstandardsbodiesofAustria,Belgium,Cyprus,CzechRepublic,Denmark,Estonia,Finland,France, Germany,Greece,Hungary,Iceland,Ireland,Italy,Latvia,Lithuania,Luxembourg,Malta,Netherlands,Norway,Poland,Portugal, Slovakia, Slovenia,Spain,Sweden,SwitzerlandandUnitedKingdom

    12、. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050Brussels 2004CEN Allrightsofexploitationinanyformandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.EN12791:2004:EEN 1279-1:2004 (E) 2 Contents Foreword3 1 Sc

    13、ope4 2 Normative references4 3 Definitions5 4 Insulating glass unit systems.8 4.1 General8 4.2 The glass panes/components 8 4.3 Cavity fillings9 4.4 Cavity inserts.9 4.5 Shapes9 4.6 Curved insulating glass units.9 5 Requirements.9 5.1 Conformity with the definition of insulating glass units .9 5.2 O

    14、ptical and visual quality of the glazed unit.11 5.3 Dimensions and dimensional tolerances12 5.3.1 General12 5.3.2 Height and width of the unit .12 5.3.3 Thickness tolerances along the periphery of the unit .13 Annex A (normative) System description of insulating glass units 15 A.1 General content of

    15、 the system description.15 A.2 The normative part of the system description15 A.2.1 Normative sub parts of the system description.15 A.2.2 The component descriptions .15 A.2.3 The processed edge seal description.16 A.3 The informative part of the system description .16 A.4 Test samples representativ

    16、e of the system description16 Annex B (normative) Tables of possibilities to substitute materials and components, and of possible changes within components 17 Annex C (informative) Optical and visual quality of the glazed unit23 C.1 Interference colouration (Brewsters fringes, Newton rings)23 C.1.1

    17、Brewsters fringes.23 C.1.2 Newton rings23 C.1.3 Others.23 C.2 Glass deflection due to variations in temperature and barometric pressure23 C.3 External condensation23 C.4 Natural colour of clear glass 23 EN 1279-1:2004 (E) 3 Foreword This document (EN 1279-1: 2004) has been prepared by Technical Comm

    18、ittee CEN /TC 129, “Glass in building“, the secretariat of which is held by IBN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2004, and conflicting national standards shall be withdraw

    19、n at the latest by December 2004. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative annex Z, which is an integ

    20、ral part of this document. This European Standard “Glass in Building - Insulating glass units” consists of the following Parts Part 1: Generalities, dimensional tolerances and rules for the system description. Part 2: Long term test method and requirements for moisture penetration. Part 3: Long term

    21、 test method and requirements for gas leakage rate and for gas concentration tolerances. Part 4: Methods of test for the physical attributes of edge seals. Part 5: Evaluation of Conformity. Part 6: Factory production control and periodic tests. The annexes A and B are normative, and annex C is infor

    22、mative. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, La

    23、tvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 1279-1:2004 (E) 4 1 Scope This European Standard is the product standard for insulating glass units, which defines insulating glass units, and ensures by m

    24、eans of the evaluation of conformity to this standard that over time: energy savings are made because the U-value and solar factor do not change significantly; health is preserved because sound reduction and vision do not change significantly; safety is provided because mechanical resistance does no

    25、t change significantly. It covers characteristics that are of importance for trade. Marking conditions are included. NOTE 1: For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply. The main intended uses o

    26、f the insulating glass units are installations in windows, doors, curtain walling, roofs and partitions where there exists protection against direct ultraviolet radiation at the edges. NOTE 2: In cases where there is no protection against direct ultraviolet radiation at the edges, such as structural

    27、 sealant glazing systems, additional European technical specifications should be followed. Units that are intended for artistic purposes are excluded from this standard. This Part of this European standard, which is inextricably bound up with the other Parts of the standard, covers the materials, th

    28、e rules for the system description, the optical and visual quality and the dimensional tolerances for insulating glass units. 2 Normative references This European Standard incorporates, by dated or undated reference, provisions from other publications. These normative references are cited at the app

    29、ropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated by amendment or revision. For undated references, the latest edition of the publicati

    30、on referred to applies. EN 572 Glass in Building - Basic soda lime silicate glass products - Parts 1: Definitions and general physical and mechanical properties Part 2: Float glass Part 3: Polished wired glass Part 4: Drawn sheet glass Part 5: Patterned glass Part 6: Wired patterned glass l Part 8:

    31、Supplied and final cut sizes EN 1096-1 Glass in Building - Coated glass - Part 1: Definitions and classification EN 1279-1:2004 (E) 5 EN 1279-2 Glass in Building - Insulating glass units - Part 2: Long term test method and requirements for moisture penetration EN 1279-3 Glass in Building - Insulatin

    32、g glass units - Part 3: Long term test method and requirements for gas leakage rate and for gas concentration tolerances EN 1279-4 Glass in Building - Insulating glass units - Part 4: Methods of test for the physical attributes of edge seals EN 1279-6 Glass in Building - Insulating glass units - Par

    33、t 6 Factory production control and periodic tests EN 1748-1-1 Glass in Building - Special Basic products - Part 1-1: Borosilicate glasses EN 1748-2-1 Glass in Building - Special Basic products - Part 2-1: Glass ceramics - Definition and description EN 1863-1 Glass in Building - Heat strengthened sod

    34、a lime silicate glass - Part 1: Definition and description EN 12150-1 Glass in Building - Thermally toughened soda lime silicate safety glass - Part 1: Definition and description EN 12337-1 Glass in Building - Chemically strengthened soda lime silicate glass - Part 1: Definition and description EN I

    35、SO 12543 Glass in Building - Laminated glass and laminated safety glass Part 1: Definition and description of component parts (ISO 12543-1:1998) Part 2: Laminated safety glass (ISO 12543-2:1998) Part 3: Laminated glass (ISO 12543-3:1998) Part 6: Appearance (ISO 12543-6:1998) EN 13024-1 Glass in Buil

    36、ding - Thermally toughened borosilicate safety glass - Part 1: Definition and description prEN 14178-1 Glass in Building - Basic alkaline earth silicate glass products - Part 1: Float glass prEN 14179-1 Glass in Building - Heat soaked thermally toughened soda lime silicate safety glass - Part 1: Def

    37、inition and description prEN 14321-1 Glass in Building - Thermally toughened alkaline earth silicate safety glass - Part 1: Definition and description 3 Definitions For the purpose of this standard, the following definitions apply. 3.1 insulating glass unit (IGU) an assembly consisting of at least t

    38、wo panes of glass, separated by one or more spacers, hermetically sealed along the periphery, mechanically stable and durable (see 5.1). NOTE: systems are available where the spacer and hermetic seal are included within a single edge sealing system. EN 1279-1:2004 (E) 6 3.2 system a range of insulat

    39、ing glass units with a common edge seal profile, edge seal materials and edge seal components as described in the system description. The range having a similar edge seal performance, e.g. moisture penetration index, gas loss rate. 3.3 system description description of components and the edge seal o

    40、f the insulating glass unit in terms relevant to identification, and in terms relevant to edge seal performance, e.g. moisture penetration index, gas loss rate. 3.4 permeation geometry the geometry of that part of the edge seal of the insulating glass unit through which the vapour and gas transmissi

    41、on takes place. For an example, see figure 1. NOTE: For TPS-type systems the permeation is through the body of the system rather than around the spacer and through the sealant. M o i s t u r e p e n e t r a t i o n G a s l o s s Figure 1 Example of a permeation geometry 3.5 cavity (cavities) the gap

    42、(s) between the panes of an insulating glass unit. 3.6 channel a profile covering and protecting the edges and/or making it possible to install the unit in frames originally designed for single glass. 3.7 corner piece a joint piece that acts as a corner of the spacer frame. EN 1279-1:2004 (E) 7 3.8

    43、dehydrated air or gas air or other gas with a low water vapour partial pressure which, when introduced into the cavity, eliminates the risk of condensation. 3.9 desiccant a product designed to lower the water vapour partial pressure inside the insulating glass unit. 3.10 desiccant cartridge a metal

    44、or plastic section, containing a desiccant, placed somewhere in the cavity. 3.11 edge seal the processed edge of an insulating glass unit, designed to ensure that moisture and gas transmissions between the inside and outside of the unit are limited, designed with a certain mechanical strength, and d

    45、esigned with a certain physical and chemical stability. 3.12 glass pane (also referred to as glass component) one sheet of glass. 3.13 inner sealant a sealant which, when applied, is in contact with the cavity of the insulating glass units. 13.14 joint piece a piece that connects parts of a spacer.

    46、3.15 outer sealant a sealant which, when applied, is in contact with the environment outside the insulating glass units 2 . 3.16 sealant organic material that, after application, has sufficient mechanical properties of cohesion and of adhesion to glass and/or spacer for use in edge seals. For the pu

    47、rpose of this standard, silicone sealant is considered to be organic. 3.17 spacer a component used to separate the panes and control the width of the gap at the edge of the unit. 3.18 external condensation condensation appearing on the glass panes of an insulating glass unit either on the room side

    48、surface or on the external surface. 3.19 internal condensation condensation appearing on the glass panes within the cavity of an insulating glass unit. 1In the case of single seal insulating glass units, the inner sealant is the same as the outer sealant. 2In the case of single seal insulating glass units, the outer sealant is the same as the inner sealant EN 1279-1:2004 (E) 8 3.20 absolute limit a value of a parameter, defined in the system description (annex A), which when exceeded requires: remedial action in manuf


    注意事项

    本文(BS EN 1279-1-2004 Glass in building - Insulating glass units - Generalities dimensional tolerances and rules for the system description《建筑物用玻璃 绝缘玻璃部件 系统描述的概要、尺寸公差和规则》.pdf)为本站会员(visitstep340)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开