欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    BS DD IEC PAS 62633-2009 Industrial communication networks - Profiles - Additional Fieldbus profiles for real-time networks based on ISO IEC 8802-3 SNpTYPE《工业通信网络 配置文件 基于ISO IEC880.pdf

    • 资源ID:548309       资源大小:902.06KB        全文页数:24页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    BS DD IEC PAS 62633-2009 Industrial communication networks - Profiles - Additional Fieldbus profiles for real-time networks based on ISO IEC 8802-3 SNpTYPE《工业通信网络 配置文件 基于ISO IEC880.pdf

    1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsWB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 1Industrial communication networks Profiles AdditionalFieldbus profiles for real-time networks based on ISO/IEC 88

    2、02-3 SNpTYPEDD IEC/PAS 62633:2009National forewordThis Draft for Development is the UK implementation of IEC/PAS 62633:2009.This publication is not to be regarded as a British Standard.It is being issued in the Draft for Development series of publications and is ofa provisional nature. It should be

    3、applied on this provisional basis, so thatinformation and experience of its practical application can be obtained.A PAS is a Technical Specification not fulfilling the requirements for a stan-dard, but made available to the public and established in an organizationoperating under a given procedure.A

    4、 review of this Draft for Development will be carried out not later than threeyears after its publication.Notification of the start of the review period, with a request for the submis-sion of comments from users of this Draft for Development, will be made inan announcement in the appropriate issue o

    5、f Update Standards. Accordingto the replies received, the responsible BSI Committee will judge whether thevalidity of the PAS should be extended for a further three years or what otheraction should be taken and pass their comments on to the relevant interna-tional committee.Observations which it is

    6、felt should receive attention before the official callfor comments will be welcomed. These should be sent to the Secretary of theresponsible BSI Technical Committee at British Standards House, 389 ChiswickHigh Road, London W4 4AL.The UK participation in its preparation was entrusted to Technical Com

    7、mitteeAMT/7, Industrial communications: process measurement and control, includ-ing fieldbus.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible

    8、for its correct application. BSI 2009ISBN 978 0 580 68883 6ICS 25.040.40; 35.100.05Compliance with a British Standard cannot confer immunity fromlegal obligations.This Draft for Development was published under the authority of theStandards Policy and Strategy Committee on 30 September 2009Amendments

    9、 issued since publicationAmd. No. Date Text affectedBRITISH STANDARDDD IEC/PAS 62633:2009IEC/PAS 62633Edition 1.0 2009-08PUBLICLY AVAILABLE SPECIFICATIONPRE-STANDARD Industrial communication networks Profiles Additional Fieldbus profiles for real-time networks based on ISO/IEC 8802-3 SNpTYPE INTERNA

    10、TIONAL ELECTROTECHNICAL COMMISSION RICS 25.040.40; 35.100.05 PRICE CODEISBN 2-8318-1056-2 Registered trademark of the International Electrotechnical Commission DD IEC/PAS 62633:2009 2 PAS 62633 IEC:2009(E) CONTENTS FOREWORD.3 INTRODUCTION.4 1 Scope.5 2 Normative references .5 3 Terms, definitions, a

    11、bbreviated terms, acronyms, and conventions.5 3.1 Terms and definitions 5 3.1.30 5 3.2 Abbreviated terms and acronyms 5 3.3 Symbols 6 3.3.12 CPF SNpFAMILY symbols .6 3.4 Conventions 6 4 Conformance to communication profiles .6 5 RTE performance indicators .6 6 Conformance tests .6 7 Communication Pr

    12、ofile Family SNpFAMILY (SafetyNET p) - RTE communication profiles .7 7.1 General overview 7 7.2 Profile SNpFAMILY/1 7 7.2.1 Physical layer 7 7.2.2 Data link layer .7 7.2.3 Application layer10 7.2.4 Performance indicator selection.11 7.3 Profile SNpFAMILY/2 14 7.3.1 Physical layer 14 7.3.2 Data link

    13、layer .14 7.3.3 Application layer17 7.3.4 Performance indicator selection.19 Table 1 CP SNpFAMILY/1: DLL service selection 7 Table 2 CP SNpFAMILY/1: DLL protocol selection .9 Table 3 CP SNpFAMILY/1: AL service selection.10 Table 4 CP SNpFAMILY/1: AL protocol selection .11 Table 5 CP SNpFAMILY/1: Per

    14、formance indicator overview.12 Table 6 CP SNpFAMILY/1: Performance indicator dependency matrix .12 Table 7 CP SNpFAMILY/2: DLL service selection 15 Table 8 CP SNpFAMILY/2: DLL protocol selection .16 Table 9 CP SNpFAMILY/2: AL service selection.17 Table 10 CP SNpFAMILY/2: AL protocol selection .18 Ta

    15、ble 11 CP SNpFAMILY/2: Performance indicator overview.19 Table 12 CP SNpFAMILY/2: Performance indicator dependency matrix .19 DD IEC/PAS 62633:2009PAS 62633 IEC:2009(E) 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ INDUSTRIAL COMMUNICATION NETWORKS PROFILES ADDITIONAL FIELDBUS PROFILES FOR REAL-TIME

    16、 NETWORKS BASED ON ISO/IEC 8802-3 SNpTYPE FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all q

    17、uestions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publicat

    18、ion(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC c

    19、ollaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opini

    20、on on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to en

    21、sure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently

    22、to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered

    23、 responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its t

    24、echnical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other

    25、IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the su

    26、bject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. A PAS is a technical specification not fulfilling the requirements for a standard, but made available to the public. IEC-PAS 62633 has been processed by subcommittee 65C: Industrial networks, of

    27、IEC technical committee 65: Industrial-process measurement, control and automation. The text of this PAS is based on the following document: This PAS was approved for publication by the P-members of the committee concerned as indicated in the following document Draft PAS Report on voting 65C/530/PAS

    28、 65C/534/RVD Following publication of this PAS, which is a pre-standard publication, the technical committee or subcommittee concerned may transform it into an International Standard. This PAS shall remain valid for an initial maximum period of 3 years starting from the publication date. The validit

    29、y may be extended for a single 3-year period, following which it shall be revised to become another type of normative document, or shall be withdrawn. DD IEC/PAS 62633:2009 4 PAS 62633 IEC:2009(E) INTRODUCTION This PAS contains an additional profile SNpTYPE which may be integrated into a future new

    30、edition of IEC 61784-2. DD IEC/PAS 62633:2009PAS 62633 IEC:2009(E) 5 INDUSTRIAL COMMUNICATION NETWORKS PROFILES ADDITIONAL FIELDBUS PROFILES FOR REAL-TIME NETWORKS BASED ON ISO/IEC 8802-3 SNpTYPE 1 Scope This Clause is identical in form and content for all CPFs to that of IEC 61784-2:2007. 2 Normati

    31、ve references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. This Clause is identical in form an

    32、d content for all CPFs to that of IEC 61784-2:2007. IEC 61784-2:2007, Industrial communication networks Profiles Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 3 Terms, definitions, abbreviated terms, acronyms, and conventions 3.1 Terms and definitions For the pu

    33、rposes of this document, the following terms and definitions apply, in addition to those of IEC 61784-2:2007. 3.1.30 real time frame line (RTFL) communication model for communication with high real time requirements 3.1.31 real time frame network (RTFN) communication model for communication with low

    34、 real time requirements 3.2 Abbreviated terms and acronyms The following additional abbreviated terms and acronyms for CPF SNpFAMILY apply, in addition to those of IEC 61784-2:2007. RTFL Real time frame line RTFN Real time frame network DD IEC/PAS 62633:2009 6 PAS 62633 IEC:2009(E) 3.3 Symbols The f

    35、ollowing additional subclause for the symbols of the new CPF SNpFAMILY applies, in addition to those of IEC 61784-2:2007. 3.3.12 CPF SNpFAMILY symbols Symbol Definition Unit lBDistance along the cable in backward direction m lCCable length m lFDistance along the cable in forward direction m NoDoB Nu

    36、mber of devices in backward direction NoDoF Number of devices in forward direction NoS Number of switching devices tCDCable delay ns/m tcycCycle time of communication system/relation s tDDelivery time s tdataTransmit time of data frame(s) s tpdPropagation delay s tSTsinkSink stack traversal time s t

    37、STsrcSource stack traversal time s tSWDelay time of a switch s 3.4 Conventions This Subclause is identical in form and content for all CPFs to that of IEC 61784-2:2007. 4 Conformance to communication profiles This Clause is identical in form and content for all CPFs to that of IEC 61784-2:2007. 5 RT

    38、E performance indicators This Clause is identical in form and content for all CPFs to that of IEC 61784-2:2007. 6 Conformance tests This Clause is identical in form and content for all CPFs to that of IEC 61784-2:2007. DD IEC/PAS 62633:2009PAS 62633 IEC:2009(E) 7 7 Communication Profile Family SNpFA

    39、MILY (SafetyNET p1) - RTE communication profiles 7.1 General overview Communication Profile Family SNpFAMILY defines profiles based on IEC/PAS 61158-3-22 through IEC/PAS 61158-6-22. In this part of IEC 61784, the following communication profiles are specified for CPF SNpFAMILY. Profile SNpFAMILY/1 T

    40、his profile defines protocol and service selection for devices which utilize the communication model real time frame line (RTFL). Profile SNpFAMILY/2 This profile defines protocol and service selection for devices which utilize the communication model real time frame network (RTFN). 7.2 Profile SNpF

    41、AMILY/1 7.2.1 Physical layer The physical layer shall be based on standard Ethernet hardware according to ISO/IEC 8802-3. CP SNpFAMILY/1 devices shall use a data rate of 100 Mbit/s and full-duplex transmission mode. A combination of full-duplex and 100Base-TX with auto crossover function (wire, 2 tw

    42、isted pairs) should be used. When using cables, they shall be rated Cat5e or better, and shielded in an appropriate way (FTP, STP or SFTP) depending upon EMC constraints. 7.2.2 Data link layer Data link layer is described in IEC/PAS 61158-3-22 and IEC/PAS 61158-4-22. Table 1 specifies the use of the

    43、 services included in this profile. Table 2 specifies the use of the protocol included in this profile. Table 1 CP SNpFAMILY/1: DLL service selection Clause or subclause of IEC/PAS 62633 Header Presence Constraints 4 Data-link layer services and concepts 4.1 Operating principle YES 4.2 Communication

    44、 models 4.2.1 Overview YES 4.2.2 RTFL device reference model YES 4.2.3 RTFN device reference model NO 4.3 Topology 1SafetyNET p is a trade name of the Pilz GmbH tcycis the cycle time of the communication system (tcycle tdata); tSTsrcis the stack traversal time including data-link layer and physical

    45、layer of the source; tdatais the time to transmit all Real-time Ethernet frames for one cycle; tCDis the cable delay (4,5 to 5 ns/m); lFis the distance along the cable in meters which is passed by the packed from source to last device of the logical line; lBis the distance along the cable in meters

    46、which is passed by the packed from last device of the logical line to sink; tpdis the propagation delay of a device in forward or backward direction; tSWis the delay caused by switching procedure; NoDoF is the number of succeeding devices on forward direction from the source to the last device of th

    47、e logical line; NoDoB is the number of succeeding devices on backward direction from the last device of the logical line to the sink; tSTsinkis the stack traversal time including data-link layer and physical layer of the sink. NOTE 1 In the case of a linear topology the time factor tSWhas the value

    48、0. NOTE 2 The distance in each direction is affected by the number of switching devices within the network topology. 7.2.4.4 Basic network topology The basic network topologies supported by this profile are hierarchical star or linear topology. It is highly recommended to use linear topology to reac

    49、h highest performance. For both basic network topologies this profile establishes a logical line topology by appropriate addressing within devices. For detailed information refer to IEC/PAS 61158-4-22. 7.2.4.5 Delivery time dependency on number of end-stations The number of end-stations typically influences the amount of data, thus the time to transmit the data frame as well as the sum of propagation delays. Furthermore the num


    注意事项

    本文(BS DD IEC PAS 62633-2009 Industrial communication networks - Profiles - Additional Fieldbus profiles for real-time networks based on ISO IEC 8802-3 SNpTYPE《工业通信网络 配置文件 基于ISO IEC880.pdf)为本站会员(livefirmly316)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开