欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    BS 89-5-1990 Direct acting indicating analogue electrical measuring instruments and their accessories - Specification for special requirements for phase meters power factor meters .pdf

    • 资源ID:547573       资源大小:439.58KB        全文页数:16页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    BS 89-5-1990 Direct acting indicating analogue electrical measuring instruments and their accessories - Specification for special requirements for phase meters power factor meters .pdf

    1、BRITISH STANDARD BS89-5:1990 EN60051-5: 1989 IEC51-5:1985 Direct acting indicating analogue electrical measuring instruments and their accessories Part 5: Specification for special requirements for phase meters, power factor meters and synchroscopes This European Standard EN60051-5 has the status of

    2、 a British Standard UDC: 621.317.77.037.33BS89-5:1990 This British Standard was published under the authority ofthe Board of BSI and comes intoeffect on 31 August1990 BSI07-1999 First published as BS89 October1919 Second edition August1926 Third edition September1937 Fourth edition February1954 Fift

    3、h edition March1977 Published as BS89-5 August1990 The following BSI references relate to the work on this standard: Committee referencePEL/13 Draft for comment88/33510DC ISBN 0 580 18445 5 Cooperating organizations The European Committee for Electrotechnical Standardization (CENELEC), under whose s

    4、upervision this European Standard was prepared, comprises the National Committees of the following countries. Austria Italy Belgium Luxemburg Denmark Netherlands Finland Norway France Portugal Germany Spain Greece Sweden Iceland Switzerland Ireland UnitedKingdom Amendments issued since publication A

    5、md. No. Date of issue CommentsBS89-5:1990 BSI 07-1999 i Contents Page Cooperating organizations Inside front cover National foreword ii Brief history 2 Text of EN60051-5 3 National appendix W Inside back coverBS89-5:1990 ii BSI 07-1999 National foreword This British Standard has been prepared under

    6、the direction of the Power Electrical Engineering Standards Policy Committee and is the English language version of EN60051-5 “Direct acting indicating analogue electrical measuring instruments and their accessories Part 5: Special requirements for phase meters, power factor meters and synchroscopes

    7、”, published by the European Committee for Electrotechnical Standardization (CENELEC). It is identical with the English language version of IEC Publication51-5 published by the International Electrotechnical Commission (IEC). This Part of BS89 together with Parts1,2,3,4,6,7,8 and9 of this standard s

    8、upersedes BS89:1977, which is withdrawn. BS89 comprises the following Parts which will be the English language version of the listed European Standards. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their cor

    9、rect application. Compliance with a British Standard does not of itself confer immunity from legal obligations. European Standard Corresponding Part of BS89 EN60051-1 Part1 Specification for definitions and general requirements common to all Parts EN60051-2 Part2 Specification for special requiremen

    10、ts for ammeters and voltmeters EN60051-3 Part3 Specification for special requirements for wattmeters and varmeters EN60051-4 Part4 Specification for special requirements for frequency meters EN60051-5 Part5 Specification for special requirements for phase meters, power factor meters and synchroscope

    11、s EN60051-6 Part6 Specification for special requirements for ohmeters (impedance meters) and conductance meters EN60051-7 Part7 Specification for special requirements for multi-function instruments EN60051-8 Part8 Specification for special requirements for accessories EN60051-9 Part9 Recommended tes

    12、t methods Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, theEN title page, pages2 to10, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the ame

    13、ndment table on the inside front cover.EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN60051-5 November 1989 UDC: 621.317.77.037.33 Key words: Electrical measuring instruments; analogue indicating instruments; direct acting measuring instruments; accessories for electrical measuring instruments;

    14、 phase meters; power factor meters; synchronoscopes English version Direct acting indicating analogue electrical measuring instruments and their accessories Part5:Specialrequirements for phase meters, power factor meters and synchroscopes (IEC51-5 (1985) edition4) Appareils mesureurs lectriques indi

    15、cateurs analogiques action directe et leurs accessoires Cinquime partie: Prescriptions particulires pour les phasemtres, les indicateurs de facteur de puissance et les synchronoscopes (CEI51-5 (1985) dition4) Direkt wirkende anzeigende elektrische Megerte und ihr Zubehr Megerte mit skalenanzeige Tei

    16、l 5: Spezielle Anforderungen fr Phasenverschiebungswinkel-Megerte, Leistungsfaktor-MeBgerte und Synchronoskope (IEC51-5 (1985) Ausgabe4) This European Standard was ratified by CENELEC on11 September1989. CENELEC members are bond to comply with the requirements of the CENELEC Internal Regulations whi

    17、ch stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CENELEC Central Secretariat or to any CENELEC member. This

    18、European Standard exists in three official versions (English, French and German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to CENELEC Central Secretariat has the same status as the official versions. CENELEC m

    19、embers are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxemburg, Netherland, Norway, Portugal, Spain, Sweden, Switzerland and UnitedKingdom. CENELEC European Committee for Electrotechnical Standardization Comit Eu

    20、ropen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels CENELEC1989 Copyright reserved to all CENELEC members Ref. No. EN60051-5:1989 EEN60051-5:1989 BSI 07-1999 2 Brief history The text of IEC-Publication51-5

    21、(4th edition 1985) was submitted to the CENELEC members for unique acceptance. Technical text The text of the International Standard IEC51-5 (4th edition 1985) was approved by CENELEC on11 September1989 as a European Standard with the following editorial corrections: Page6, Table II-5, column4, for

    22、“distortion of voltage and/or current components of the measured quantity”: replace3.7.3 by3.7.4. Page7, note2 c): replace “S.I.” by “SI”. The following dates are applicable: Contents Page Brief history 2 Foreword 3 1 Scope 3 2 Definitions 3 3 Description, classification and compliance 4 4 Reference

    23、 conditions and intrinsic errors 4 5 Nominal range of use and variations 5 6 Further electrical and mechanical requirements 5 7 Constructional requirements 9 8 Information, general markings and symbols 9 9 Markings and symbols for terminals 9 10 Tests to prove compliance with this standard 9 Table I

    24、-5 Reference conditions and tolerances, additional to those given in Table I-1, for testing purposes 4 Table II-5 Limits of the nominal range of use and permissible variations additional to those given in Table II-1 6 Table IV-5 Overloads of short duration 8 latest date of announcement of the EN at

    25、national level (doa): 1990-03-01 date of latest publication of a new harmonized standard(dop): 1990-09-01 date of withdrawal of conflicting national standards (dow): 1990-09-01EN60051-5:1989 BSI 07-1999 3 Foreword 1) The formal decisions or agreements of the IEC on technical matters, prepared by Tec

    26、hnical Committees on which all the National Committees having a special interest therein are represented, express, as nearly as possible, an international consensus of opinion on the subjects dealt with. 2) They have the form of recommendations for international use and they are accepted by the Nati

    27、onal Committees in that sense. 3) In order to promote international unification, the IEC expresses the wish that all National Committees should adopt the text of the IEC recommendation for their national rules in so far as national conditions will permit. Any divergence between the IEC recommendatio

    28、n and the corresponding national rules should, as far as possible, be clearly indicated in the latter. Preface This standard has been prepared by IEC Technical Committee No.85: Measuring Equipment for Basic Electrical Quantities (former Sub-Committee13B: Electrical Measuring Instruments). This fourt

    29、h edition replaces the third edition of IEC Publication51. This standard constitutes Part5. The general layout for the revised Publication51 is as follows: Part1: Definitions and General Requirements Common to all Parts; Part2: Special Requirements for Ammeters and Voltmeters; Part3: Special Require

    30、ments for Wattmeters and Varmeters; Part4: Special Requirements for Frequency Meters; Part5: Special Requirements for Phase Meters, Power Factor Meters and Synchroscopes; Part6: Special Requirements for Ohmmeters (Impedance Meters) and Conductance Meters; Part7: Special Requirements for Multi-functi

    31、on Instruments; Part8: Special Requirements for Accessories; Part9: Recommended Test Methods. Parts2 to9 are not complete in themselves and shall be read in conjunction with Part1. All of these parts are arranged in the same format and a standard relationship between subject and clause number is mai

    32、ntained throughout. In addition, tables, figures and appendices add a suffix to the part number in order to differentiate the parts. This re-arrangement will assist the reader of IEC Publication51 to distinguish information relating to the different types of instruments. The text of this standard is

    33、 based upon the following documents: Further information can be found in the relevant Reports on Voting indicated in the table above. 1 Scope 1.1 Part5 of this standard applies to direct acting indicating analogue phase meters, power factor meters and synchroscopes. 1.2 This part also applies to non

    34、-interchangeable accessories (as defined in Sub-clause2.1.15.3 of Part1) used with phase meters, power factor meters and synchroscopes. 1.3 This part also applies to a phase meter or power factor meter whose scale marks do not correspond directly to its electrical input quantity, provided that the r

    35、elationship between them is known. 1.4 to1.8 See Part1. 2 Definitions See Part1. Six Months Rule Report on Voting Two Months Procedure Report on Voting 13B(CO)88 13B(CO)97 13B(CO)103 85(CO)1EN60051-5:1989 4 BSI 07-1999 3 Description, classification and compliance 3.1 Description Phase meters, power

    36、factor meters and synchroscopes shall be described according to their method of operation as given in Sub-clause2.2 of Part1. 3.2 Classification Phase meters, power factor meters and synchroscopes shall be classified in one of the accuracy classes denoted by the following class indices: 0.1, 0.2, 0.

    37、3, 0.5, 1, 1.5, 2, 2.5, 3, 5. 3.3 Compliance with the requirements of this standard See Part 1. 4 Reference conditions and intrinsic errors 4.1 Reference conditions 4.1.1 The reference values of the influence quantities shall be as given in Table I-1 and Table I-5. Table I-5 Reference conditions and

    38、 tolerances, additional to those given in Table I-1,fortesting purposes 4.1.2 See Part1. 4.1.3 Reference conditions different from those given in Table I-1 and Table I-5 may be specified, but they shall then be marked in accordance with Clause8 of Part1. 4.2 Limits of intrinsic error, fiducial value

    39、 See Part1. For a synchroscope, the accuracy requirements apply only at the synchronizing mark. 4.2.1 Correspondence between intrinsic error and accuracy class See Part1. 4.2.2 Fiducial value The fiducial value corresponds to90 electrical degrees. The class index is marked using Symbol E-1 given in

    40、Table III-1 of Part1 (see Part1, Clause8). Influence quantity Reference conditions unless otherwise marked Tolerance permitted for testing purposes, applicable for a single reference value a Voltage component of the measured quantity Rated voltage or any voltage within the reference range, if any 2%

    41、 of the rated value Current component of the measured quantity 40% .100% of rated current Phase balance (for polyphase instruments) Symmetrical voltages and currents b Frequency of current and voltage components of the measured quantity Instruments using phase shifting devices Reference frequency 0.

    42、1% of the reference frequency Other instruments 45Hz to65Hz 2% of the reference frequency a This tolerance applies when a single reference value is specified in this table or is marked by the manufacturer. For a reference range, no tolerance is allowed. b Each of the voltages (between any two lines

    43、or between line and neutral) should not differ by more than1% from the average of the voltages (line-to-line or line-to-neutral) of the system. Each of the currents in the phases should not differ by more than1% from the average of the currents. The angles between each of the currents and the corres

    44、ponding phase-to-neutral voltages should not differ by more than2 from the average of the angles.EN60051-5:1989 BSI 07-1999 5 5 Nominal range of use and variations 5.1 Nominal range of use See Part1 and Table II-5. 5.2 Limits of variations See Part1 and Table II-5. 5.3 Conditions for the determinati

    45、on of variations See Part1. 6 Further electrical and mechanical requirements 6.1 Voltage tests, insulation tests and other safety requirements See Part1. 6.2 Damping The requirements of Part1 do not apply to phase meters, power factor meters and synchroscopes. 6.3 Self-heating See Part1. However, th

    46、e requirements of Part1 do not apply to synchroscopes. 6.4 Permissible overloads 6.4.1 Continuous overload For the recommended test, see Part9, Sub-clause4.6. All phase meters and power factor meters, together with their non-interchangeable accessory(ies), if any, except for instruments fitted with

    47、a non-locking switch, shall be subjected to a continuous overload of120% of the rated value for all current circuits simultaneously for a period of2h. After having cooled to the reference temperature, the instrument together with its non-inter-changeable accessory(ies), if any, shall comply with its

    48、 accuracy requirements but without repeating the overload. The continuous overload test shall be carried out under reference conditions except for current. The requirement for continuous overload does not apply to synchroscopes. 6.4.2 Overloads of short duration For the recommended test, see Part9,

    49、Sub-clause4.4. All phase meters, power factor meters and synchroscopes, together with their non-interchangeable accessory(ies), if any, shall be subjected to overloads of short duration. However, these requirements do not apply to instruments whose scale marks do not correspond directly to their electrical input quantities but not excluding instruments intended to be used with (an) instrument transformer(s). 6.4.2.1 The values of current and voltage for the overloads of short duration shall be the


    注意事项

    本文(BS 89-5-1990 Direct acting indicating analogue electrical measuring instruments and their accessories - Specification for special requirements for phase meters power factor meters .pdf)为本站会员(roleaisle130)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开