欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    BS 7334-5-1992 Measuring instruments for building construction - Methods for determining accuracy in use of optical plumbing instruments《建筑施工用测量仪器 第5部分 光学铅垂测量仪器使用精度的测定方法》.pdf

    • 资源ID:546718       资源大小:646.87KB        全文页数:18页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    BS 7334-5-1992 Measuring instruments for building construction - Methods for determining accuracy in use of optical plumbing instruments《建筑施工用测量仪器 第5部分 光学铅垂测量仪器使用精度的测定方法》.pdf

    1、BRITISH STANDARD BS7334-5: 1992 ISO8322-5: 1991 Measuring instruments for building construction Part5: Methods for determining accuracy in use of optical plumbing instrumentsBS7334-5:1992 This British Standard, having been prepared under the directionof the Basic Data andPerformance Criteria for Civ

    2、ilEngineering and BuildingStructures StandardsPolicy Committee, waspublished under the authorityof the Standards Boardand comes into effect on 31 March1992 BSI 08-1999 The following BSI references relate to the work on this standard: Committee reference BDB/4 Draft for comment 88/10403 DC ISBN 0 580

    3、 20619 X Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Basic Data and Performance Criteria for Civil Engineering and Building Structures Standards Policy Committee (BDB/-) to Technical Committee BDB/4, upon which the following bodies w

    4、ere represented: Association of County Councils Brick Development Association British Standards Society Building Employers Confederation Chartered Institution of Building Services Engineers Concrete Society Department of Education and Science Department of the Environment (Building Research Establis

    5、hment) Incorporated Association of Architects and Surveyors Institute of Clerks of Works of Great Britain Inc. Institution of Civil Engineers Institution of Structural Engineers Institution of Water and Environmental Management Royal Institute of British Architects Royal Institution of Chartered Sur

    6、veyors Society of Chief Architects of Local Authorities The following body was also represented in the drafting of the standard, through subcommittees and panels: Chartered Institute of Building Amendments issued since publication Amd. No. Date CommentsBS7334-5:1992 BSI 08-1999 i Contents Page Commi

    7、ttees responsible Inside front cover National foreword ii 1 Scope 1 2 Normative references 1 3 General 1 4 Procedures for optical plumbing instruments (optical plummets) 3 Figure 1 Flow diagram for accuracy-in-use tests 2 Table 1-A Optical plumbing instrument Method1: Example of field observations a

    8、nd calculation 7 Table 1-B Optical plumbing instrument Method1: Field observations and calculation 8 Table 2-A Optical plumbing instrument Method2: Example of field observations and calculation 9 Table 2-B Optical plumbing instrument Method2: Field observations and calculation 10 Publication(s) refe

    9、rred to Inside back coverBS7334-5:1992 ii BSI 08-1999 National foreword This Part of BS7334 has been prepared under the direction of the Basic Data and Performance Criteria for Civil Engineering and Building Structures Standards Policy Committee. It is identical with ISO8322-5:1991 “Building constru

    10、ction Measuring instruments Procedures for determining accuracy in use Part5: Optical plumbing instruments” published by the International Organization for Standardization (ISO), and gives the testing procedures to be adopted for optical plumbing instruments. The series of Parts comprising BS7334 wi

    11、ll assist in ascertaining whether particular measuring equipment is appropriate to intended measuring tasks; they are also intended for assessing the accuracy in use of measuring instruments in general use on construction sites. The Parts are referred to in BS5606:1990 “Guide to accuracy in building

    12、”. ISO8322 consists of the following parts, under the general title “Building construction Measuring instruments Procedures for determining accuracy in use: Part1: Theory; Part2: Measuring tapes; Part3: Optical levelling instruments; Part4: Theodolites; Part5: Optical plumbing instruments; Part6: La

    13、ser instruments; Part7: Instruments when used for setting out; Part8: Electronic distance-measuring instruments up to150m; Part9: Electronic distance-measuring instruments up to500m; Part10: Testing short-range reflectors. The Technical Committee has reviewed the provisions of ISO7077, to which refe

    14、rence is made in the text, and has decided that they are acceptable for use in conjunction with this standard. Cross-references International Standard Corresponding British Standard ISO3534:1977 a BS5532 Statistical terminology Part1:1978 Glossary of terms relating to probability and general terms r

    15、elating to statistics (Identical) ISO4463-1:1989 BS5964 Building setting out and measurement Part1:1990 Methods of measuring, planning and organization and acceptance criteria (Identical) ISO7078:1985 BS6953:1988 Glossary of terms for procedures for setting out, measurement and surveying in building

    16、 construction (including guidance notes) (Identical) a ISO3534 is also related to BS4778 “Quality vocabulary” Part2:1979 “National terms”.BS7334-5:1992 BSI 08-1999 iii A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsibl

    17、e for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i to iv, pages1to10, an inside back cover and a back cover. This standard has been updat

    18、ed (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.iv blankBS7334-5:1992 BSI 08-1999 1 1 Scope This part of ISO8322 specifies test procedures to be adopted when determining and assessing the accuracy in use of opt

    19、ical plumbing instruments (optical plummets) for measurement purposes. The procedures given in this part of ISO8322 apply when these instruments are used in building construction for surveying, check and compliance measurements, and also when obtaining accuracy data. 2 Normative references The follo

    20、wing standards contain provisions which, through reference in this text, constitute provisions of this part of ISO8322. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this part of ISO8322 are encouraged to inve

    21、stigate the possibility of applying the most recent editions of the standards indicated below. Members of IEC and ISO maintain registers of currently valid International Standards. ISO3534:1977, Statistics Vocabulary and symbols. ISO4463-1:1989, Measurement methods for building Setting-out and measu

    22、rement Part1:Planning and organization, measuring procedures, acceptance criteria. ISO7077:1981, Measuring methods for building General principles and procedures for the verification of dimensional compliance. ISO7078:1985, Building construction Procedures for setting out, measurement and surveying

    23、Vocabulary and guidance notes. 3 General 3.1 Before commencing surveying, check and compliance measurements, when obtaining accuracy data or setting out, it is important that the operator investigate whether the accuracy in use of the measuring equipment is appropriate to the intended measuring task

    24、. This International Standard recommends that the operator carry out test measurements under field conditions to establish the accuracy achieved when he uses a particular measuring instrument and its ancillary equipment. To ensure that the assessment takes account of various environmental influences

    25、, two series of measurements need to be carried out under different conditions. The particular conditions to be taken into account may vary depending on where the tasks are to be undertaken. These conditions will include variations in air temperature, wind speed, cloud cover and visibility. Note sho

    26、uld also be made of the actual weather conditions at the time of measurement and the type of surface over which the measurements are made. The sets of conditions chosen for the tests should match those expected when the intended measuring task is actually carried out. See ISO7077 and ISO7078. The pr

    27、ocedures are designed so that the systematic errors are largely eliminated and assume that the particular instruments are in known and acceptable states of user adjustment according to methods detailed in the manufacturers handbooks. Accuracy-in-use procedures require repeat tests to be made with th

    28、e same instrumentation and the same observer, within a short interval of time. These are “repeatability conditions” as defined in ISO3534. The accuracy in use is expressed in terms of the standard deviation. 3.2 Figure 1 indicates schematically the decisions to be made when establishing that the acc

    29、uracy associated with a given surveying method and particular measuring equipment is appropriate to the intended measuring task. In particular, the decisions apply when adopted by a particular operator under a range of environmental conditions which are likely to occur when the task is actually carr

    30、ied out. Where the contract documentation specifies the required tolerance for the intended measuring task, it is recommended that this tolerance, which is normally given in terms of the permitted deviation P (P =2,5B) of the measuring task, be compared with the accuracy-in-use data obtained either

    31、from previous accuracy-in-use tests or from general data A which indicate the expected accuracy in use of given measuring equipment. On those occasions that the previously obtained data indicate that the accuracy in use associated with the given measuring equipment does not meet the specified permit

    32、ted deviation of the measuring task, consideration should be given to either selecting a different method and/or a more precise instrument or discussing with the designer the need for such a small permitted deviation. See ISO4463-1.BS7334-5:1992 2 BSI 08-1999 Assumptions: P is the permitted deviatio

    33、n of the measuring task A is the accuracy in use, generally expressed as deviation A (both P and A are considered to include the dimensional variability associated with 2.5 times the standard deviationB) s are the standard deviations obtained in field tests Figure 1 Flow diagram for accuracy-in-use

    34、testsBS7334-5:1992 BSI 08-1999 3 Before obtaining an overall estimate of the accuracy in use, it is recommended that each standard deviation for a given series of measurements undertaken under particular environmental conditions be compared, as indicated in Figure 1, to the specified permitted devia

    35、tion. Where the comparison shows that the specified permitted deviation has not been achieved for one series of measurements, an additional series of measurements should be carried out under environmental conditions as near as possible similar to those which applied in that original series of measur

    36、ements. 4 Procedures for optical plumbing instruments (optical plummets) 4.1 General The accuracy of any type of plumbing instrument is dependent on the vertical distance over which the plumbing operation is carried out. Thus the achievable accuracy in use is commonly expressed as a relative lateral

    37、 deviation defined as the ratio of the accuracy achieved against the difference in height. 4.2 Types of optical plumbing instruments These are three types of optical plumbing instruments. a) Instruments with a spirit-level. A cross levelling is recommended before each observation so that the line of

    38、 sight is coincident with the plumb line. b) Instruments with one compensator. The compensator ensures that the line of sight is in a vertical plane such that the plumb line is the intersection of two vertical planes perpendicular to each other. c) Instruments with two compensators. The compensators

    39、 work in two planes perpendicular to each other such that the plumb line is coincident with the line of sight. Each of the three types of instruments can have either a simple telescope sight or one incorporating a laser. Optical plumbing instruments (optical plummets) are able to sight either upward

    40、s or downwards or both. The procedure is the same in all cases. 4.3 Test methods for accuracy 4.3.1 General The following test procedure shall be adopted for determining the accuracy in use, by a particular survey team with a particular instrument and its ancillary equipment. Two alternative methods

    41、 are proposed. The first is simpler to carry out (method1); the second is more sophisticated, needs better ancillary equipment and more calculation (method2). The ancillary equipment for method1 is the cheaper, but method2 gives an improved estimation of the accuracy in use. To minimize the effects

    42、of systematic errors, it is recommended that each measurement with an optical plumbing instrument consist of two observations carried out by observing with the telescope in diametrically opposed positions. 4.3.2 Method1 The measurement results should be given in a table (see Table 1-B). An example o

    43、f a completed table is given in Table 1-A. 4.3.2.1 Observations a) Design a target in such a way that marks can be made on the horizontal surface and their location read with reference to a transparent rectangular x, y grid overlay graduated in millimetres. The horizontal surface shall be formed of

    44、a material which will accept pencil and can be easily wiped clean. This will ensure that successive pencil marks are not biased in any way by previous marks. Fix the transparent overlay so that it always returns to the same position. Establish such a target at a height comparable with that of the in

    45、tended task and locate it approximately vertically above/below the mark over/under which the instrument is centred. The orientation of the cross-hairs of the telescope shall be parallel to the axes of the target during every observation. b) Table 1-A is an example using an optical plumbing instrumen

    46、t with one compensator. Each measurement for x (or y) shall consist of two observations carried out by observing with the telescope in diametrically opposed positions. (See columns3 and5.) If an instrument with a spirit-level or with two compensators is used, each position of the telescope provides

    47、values of x and y simultaneously. Thus two opposing positions of the telescope suffice. c) Record the environmental conditions. Changes in environmental conditions during the construction period may render the test result inapplicable. In such a case repeat the test under the new conditions.BS7334-5

    48、:1992 4 BSI 08-1999 4.3.2.2 Calculation procedure A complete example of the analysis is given in Table 1-A, columns4,6,7,8,9 and10, for an optical plumbing instrument with one compensator using the measurements given in columns3 and5 and it is recommended that this form of presentation be generally

    49、adopted. a) Calculate in column4 the mean x =(x 1 + x 2 )/2 and in column6 the mean y =(y 1 + y 2 )/2 EXAMPLE b) Calculate the means and from x 1 , x 2 .x 10and y 1 , y 2 . y 10 . EXAMPLE c) Calculate the deviations v x =(x) and v y =(y) in columns7 and9 from the arithmetic means. To minimize the effect of rounding errors, the calculation of each deviation v should be carried out to the nearest0,01mm. As an arithmetic check, the sum of the10 deviations in the x and y directions should be approximately z


    注意事项

    本文(BS 7334-5-1992 Measuring instruments for building construction - Methods for determining accuracy in use of optical plumbing instruments《建筑施工用测量仪器 第5部分 光学铅垂测量仪器使用精度的测定方法》.pdf)为本站会员(roleaisle130)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!